Thin collagen film scaffolds for retinal epithelial cell culture.

Collagen films have been used in biological implantation and surgical grafts. The development of thin collagen films on the order of 10 microm thick that ensure a planar distribution of implanted cells is a necessary step towards surgical grafts for treatment of age-related macular degeneration (AMD). Here, collagen films were manufactured on a Teflon support to a thickness of 2.4+/-0.2 microm, comparable to that of native Bruch's membrane. Because one important function of Bruch's membrane is allowing the flow of nutrients and waste to and from the retinal pigment epithelium the diffusion properties of the collagen films were studied using blind-well chambers. The diffusion coefficient of the collagen film was determined to be 4.1 x 10(-10)cm(2)/s for 71,200 Da dextran molecules. Viability studies utilizing the blind-well chambers also confirmed that nutrient transport through the films was sufficient to sustain retinal pigment epithelial (RPE) cells. The films were bioassayed in a RPE cell culture model to confirm cell attachment and viability. RPE cells were shown to form an epithelial phenotype and were able to phagocytize photoreceptor outer segments.

Biocompatible Materials↗

A model retinal interface based on directed neuronal growth for single cell stimulation.

In this work, we use cell micropatterning technologies to direct neuronal growth to individual electrodes, and demonstrate that such an approach can achieve selective stimulation and lower stimulation thresholds than current field-effect based retinal prostheses. Rat retinal ganglion cells (RGCs) were purified through immunopanning techniques, and microcontact printing (microCP) was applied to align and pattern laminin on a microelectrode array, on which the RGCs were seeded and extended neurites along the pattern to individual electrodes. The stimulation threshold currents of RGCs micropatterned to electrodes were found to be significantly less than those of non-patterned RGCs over a wide range of electrode-soma distances, as determined with calcium imaging techniques. Moreover, the stimulation threshold for micropatterned cells was found to be independent of electrode-soma distance, and there was no significant effect of microCP on cell excitability. The effects of additional stimulation parameters, such as electrode size and pulse duration, on threshold currents were determined. The stimulation results quantitatively demonstrate the potential benefits of a retinal prosthetic interface based on directed neuronal growth.

Action Potentials↗

Neural stimulation with a carbon nanotube microelectrode array.

We present a novel prototype neural interface using vertically aligned multiwalled carbon nanotube (CNT) pillars as microelectrodes. Functionalized hydrophilic CNT microelectrodes offer a high charge injection limit (1-1.6 mC/cm2) without faradic reactions. The first repeated in vitro stimulation of hippocampal neurons with CNT electrodes is demonstrated. These results suggest that CNTs are capable of providing far safer and more efficacious solutions for neural prostheses than previous metal electrode approaches.

Action Potentials↗

Determination of human lens capsule permeability and its feasibility as a replacement for Bruch's membrane.

We have investigated human anterior lens capsule as a potential replacement for Bruch's membrane as a treatment for age-related macular degeneration. Any substrate to replace Bruch's membrane should possess certain characteristics to maintain proper function of the overlying retina. One of the important properties of Bruch's membrane is allowing the flow of nutrients and waste between the retinal pigment epithelium and the choriocapillaris. Here, we measured the permeability of the lens capsule by studying the diffusion of various molecular weight FITC-dextran molecules. Expressions for extraction of diffusion coefficients from concentration vs. time data from a blind-well chamber apparatus were derived for both a single and double membrane experiments. The diffusion coefficients in the lens capsule were found to be in the range of 10(-6) to 10(-10)cm2/s. We demonstrated a power law relationship, with the diffusion coefficient possessing a -0.6 order dependence on molecular weight. The molecular weight exclusion limit was determined to be 150+/-40 kDa. We have compared this value with reported values of Bruch's membrane molecular weight exclusion limit and find that the lens capsule has the potential to act as a substitute Bruch's membrane.

Bruch Membrane↗

Localized chemical release from an artificial synapse chip.

A device that releases chemical compounds in small volumes and at multiple, well defined locations would be a powerful tool for clinical therapeutics and biological research. Many biomedical devices such as neurotransmitter-based prostheses or drug delivery devices require precise release of chemical compounds. Additionally, the ability to control chemical gradients will have applications in basic research such as studies of cell microenvironments, stem cell niches, metaplasia, or chemotaxis. We present such a device with repeatable delivery of chemical compounds at multiple locations on a chip surface. Using electroosmosis to drive flow through microfluidic channels, we pulse minute quantities of a bradykinin solution through four 5-microm apertures onto PC12 cells and show stimulation of individual cells using a Ca(2+)-sensitive fluorescent dye. We also present basic computational results with experimental verification of both fluid ejection and fluid withdrawal by imaging pH changes by using a fluorescent dye. This "artificial synapse chip" is a prototype neural interface that introduces a new paradigm for neural stimulation, with eventual application in treating macular degeneration and other neurological disorders.

Animals↗

Controlling cell adhesion on human tissue by soft lithography.

Soft lithographic techniques are widely used for fundamental biological applications. This study investigates the extension of soft lithography for use on human tissue to create a biological implant by systematically studying the effect of pattern size on cellular morphology. We focus on mimicking a key layer of the physiological retina with an organized monolayer of epithelial cells to act as a new treatment for age-related macular degeneration. We show that epithelial cells can be confined to cytophilic islands defined on lens capsule by the inhibitory polymer poly(vinyl alcohol). In addition, as the size of the cytophilic islands grows, both the fraction of islands with cells attached and the number of cells adhered to each island increase. High densities of cell adhesion and single cell attachment per island were achieved with a 25 microm pattern size. Over time, the cells spread over the 5 microm wide barriers to form a confluent monolayer that may eventually serve as a functional retinal implant. With the ability to apply soft lithography to tissue samples, human tissue may become a universal membrane substrate for other ocular diseases or in tissue engineering applications elsewhere in the body.

Biocompatible Materials↗

Fluid flow past an aperture in a microfluidic channel.

Electroosmotically driven flow in neurotransmitter-based retinal prostheses offers a novel approach to interfacing the nervous system. Here, we show that electroosmotically driven flow in a microfluidic channel can be used either to eject or to withdraw fluid through a small aperture in the channel wall. We study this fluid movement numerically using a finite-element method and experimentally using microfabricated channels and apertures. Two devices are used to test the concept of fluid ejection and withdrawal: (1) a single, large channel with four apertures and (2) a prototype neural interface with four individually addressable apertures. We compared experimental and numerical results in microchannels using the observed pH dependence of the fluorescent dye fluorescein, finding good agreement between the results. Because of the simplicity and rapid response of electroosmotic flow, this technique may be useful for neurotransmitter-based neural interfaces.

Journal Article↗

Directed retinal nerve cell growth for use in a retinal prosthesis interface.

PURPOSE: Retinal prosthetic devices that use microelectrode arrays to stimulate retinal nerve cells may provide a viable treatment for degenerative retinal diseases. Current devices are based on electrical field-effect stimulation of remaining functional neural elements. However, the distance between target neurons and electrodes limits the potential density of electrodes and the ability to stimulate specific types of retinal neurons that contribute to visual perceptions. This study was conducted to investigate the use of microcontact printing (muCP) to direct cultured or explant retinal ganglion cell (RGC) neurites to precise and close stimulation positions and to evaluate the cell types that grow from a retinal explant. METHODS: RGCs and whole retinal explants were isolated from postnatal day-7 Sprague-Dawley rats using immunopanning purification and microdissection, respectively. Aligned muCP was used to direct the growth of RGC neurites from pure cultures (n=105) and retinal explants (n=64) along laminin patterns and to individual microelectrodes. Immunofluorescence stains (n=39) were used to determine the cell types that grew out from the retinal explants. RESULTS: RGC neurite growth was directed reproducibly along aligned laminin micropatterns to individual microelectrodes in pure RGC cultures and from full-thickness explanted rat retinas in 92% of experiments, neurites from pure RGC cultures extended along the laminin lines with an average length of 263 +/- 118 microm (SD; n=27) after 24 hours. Neurites from retinal explants extended in more than 80% of experiments and were observed to grow to an average length of 279 +/- 78 microm (n=64) after 2 days in culture. These neurites grew up to 3 mm after 1 month of culture on the laminin micropatterns. Immunohistochemical stains demonstrated that extended processes from both RGCs and glial cells grew out of retinal explants onto stamped laminin lines. CONCLUSIONS: Using muCP to pattern surfaces with growth factors, individual neuronal processes from pure RGC culture and whole retinal explants can be directed to discrete sites on a microelectronic chip surface. By directing RGC neurite processes to specific sites, single cell stimulation becomes possible. This may allow discrete populations of retinal neurons to be addressed so that physiologic retinal processing of visual information can be achieved.

Animals↗

The Artificial Synapse Chip: a flexible retinal interface based on directed retinal cell growth and neurotransmitter stimulation.

The Artificial Synapse Chip is an evolving design for a flexible retinal interface that aims to improve visual resolution of an electronic retinal prosthesis by addressing cells individually and mimicking the physiological stimulation achieved in synaptic transmission. We describe three novel approaches employed in the development of the Artificial Synapse Chip: (i) micropatterned substrates to direct retinal cell neurite growth to individual stimulation sites; (ii) a prototype retinal interface based on localized neurotransmitter delivery; and (iii) the use of soft materials to fabricate these devices. By patterning the growth of cells to individual stimulation sites, we can improve the selectivity of stimulation and decrease the associated power requirements. Moreover, we have microfabricated a neurotransmitter delivery system based on a 5- micro m aperture in a 500-nm-thick silicon nitride membrane overlying a microfluidic channel. This device can release neurotransmitter volumes as small as 2 pL, demonstrating the possibility of chemical-based prostheses. Finally, we have fabricated and implanted an equivalent device using soft flexible materials that conform to the retinal tissue more effectively. As many of the current retinal prosthesis devices use hard materials and electrical excitation at a lower resolution, our approach may provide more physiologic retinal stimulation.

Animals↗

Localized neurotransmitter release for use in a prototype retinal interface.

PURPOSE: Current neural prostheses use electricity as the mode of stimulation, yet information transfer in neural circuitry is primarily through chemical transmitters. To address this disparity, this study was conducted to devise a prototype interface for a retinal prosthetic based on localized chemical delivery. The goal was to determine whether fluidic delivery through microfabricated apertures could be used to stimulate at single-cell dimensions. METHODS: A drug delivery system was microfabricated based on a 5- or 10- microm aperture in a 500-nm thick silicon nitride membrane to localize and limit transmitter release. The aperture overlies a microfluidic delivery channel in a silicone elastomer. To demonstrate the effectiveness of this transmitter-based prosthesis, rat pheochromocytoma cells (PC12 cell line) were grown on the surface of the device to test the precision of stimulation, using bradykinin as a stimulant and measuring fluorescence from the calcium indicator, fluo-4. RESULTS: The extent of stimulation could be controlled accurately by varying the concentration of stimulant, from a single cell adjacent to the aperture to a broad area of cells. The stimulation radius was as small as 10 microm, corresponding to stimulation volumes as small as 2 pL. The relationship between the extent of stimulation and concentration was linear. CONCLUSIONS: The demonstration of localized chemical stimulation of excitable cells illustrates the potential of this technology for retinal prostheses. Although this is only a proof of concept of neurotransmitter stimulation for a retinal prosthesis, it is a significant first step toward mimicking neurotransmitter release during synaptic transmission.

Aniline Compounds↗

Microcontact printing on human tissue for retinal cell transplantation.

OBJECTIVES: To demonstrate that microcontact printing, a modern materials fabrication technique, can be used to engineer the surface of human tissue and to show that inhibitory molecules can be used to pattern the growth of retinal pigment epithelial cells or iris pigment epithelial cells on human lens capsule for transplantation. METHODS: Photolithographic techniques were used to fabricate photoresist-coated silicon substrates into molds. Poly(dimethylsiloxane)stamps for microcontact printing were made from these molds. The poly(dimethylsiloxane) stamps were then used to "wet-transfer" growth inhibitory molecules to the surface of prepared human lens capsules that were obtained during cataract surgery. Human retinal pigment epithelial and rabbit iris pigment epithelial cells were grown on a lens capsule substrate in the presence and absence of a patterned array of inhibitory factors. RESULTS: We found that human lens capsule could be microprinted with a precision similar to that obtained on glass or synthetic polymers. Retinal pigment epithelial cells and iris pigment epithelial cells cultured onto an untreated lens capsule showed spreading and formed into fusiform-appearing cells. In contrast, cells cultured on a lens capsule with a hexagonal micropattern of growth inhibitory molecules retained an epithelioid form within the inhibitory hexagons. CONCLUSION: Inhibitory growth molecules can be micropatterned onto human lens capsule, and these micropatterns can control the organization of retinal pigment epithelial cells or iris pigment epithelial cells cultured onto the lens capsule surface. CLINICAL RELEVANCE: Microprinting on autologous human tissue may facilitate efforts to effectively organize cell cultures and transplantations for the replacement of vital ocular tissues such as the retinal pigment epithelium in age-related macular degeneration.

Animals↗