Ion sampling effects under conditions of total solvent consumption.

The motivation of this work was to study some of the properties of nanoelectrospray operation under conditions where the entire sprayed liquid is vaporized and inhaled into the vacuum system. Under these conditions the desolvation requirements, sampling efficiency, concentration versus mass sensitivity, and molar response characteristics of various compounds were studied. The combined efficiency of ion production from solution and transfer into the vacuum system, referred to as sampling efficiency, is presented under various inlet conditions including different flow rates, solution compositions, and compound types. Under ideal solvent conditions the results for favorable compounds show sampling efficiencies of 70-85% at flows in the range of 50-500 nL/min. Efficiencies were lower for aqueous samples and compounds of different structures gave different molar response factors under these high sampling efficiency conditions. The relative molar response factors are presented in terms of those observed with higher flow rate sources which operate at significantly lower sampling efficiencies. In all cases, operating in this flow regime, the ion count rate was directly proportional to the absolute mass of analyte molecules entering the source. The experimental source used to carry out these studies included gas nebulization to stabilize the electrospray process, a heated laminar flow chamber to enhance desolvation and ion production, and various atmosphere-to-vacuum aperture diameters to maximize ion transfer.

Journal Article↗

Particle discriminator interface for nanoflow ESI-MS.

An atmosphere to vacuum interface was designed to exploit the different mobility and momentum characteristics of ions, and charged and neutral particles in electrospray ionization-mass spectrometry. The purpose of this device is to transmit with high efficiency the ions created at atmospheric pressure into the mass analyzer and to deflect the large charged and neutral particles prior to entrance into the vacuum system, thereby maintaining system cleanliness and stability. This interface is particularly suitable for low flow rate electrospray ionization-mass spectrometry where the close proximity of the electrospray emitters to the vacuum entrance, and near total consumption of the entire spray, leads to the production of large quantities of non-desolvated droplets and large charged and neutral particles. The improvement involves the application of potential gradients to a particle discriminator space located between the gas restricting ion entrance orifice of the mass spectrometer and the exit of a heated laminar flow chamber to divert large particles from the gas conductance limiting orifice. A counter-current flow of drying gas is used to deflect neutral particles and solvent vapor. Two stages of desolvation are achieved with the combined effects of the curtain gas and heated laminar flow chamber. This enhances the efficiency of desolvation and ion production, and stabilizes the resulting ion current under a wide variety of solvent compositions. In addition, this system eliminates the problems associated with the boiling of solution in nanospray tips when operated in close proximity to a heated mass spectrometer inlet. The particle discriminator interface gives approximately a 2-fold improvement in ion count rates, and a 3-fold improvement in stability (as measured by the signal relative standard deviation).

Algorithms↗