Test protocols for evaluation of spinal implants.

Prior to implantation, medical devices are subjected to rigorous testing to ensure safety and efficacy. A full battery of testing protocols for implantable spinal devices may include many steps. Testing for biocompatibility is a necessary first step. On selection of the material, evaluation protocols should address both the biomechanical and clinical performance of the device. Before and during mechanical testing, finite element modeling can be used to optimize the design, predict performance, and, to some extent, predict durability and efficacy of the device. Following bench-type evaluations, the biomechanical characteristics of the device (e.g., motion, load-sharing, and intradiscal pressure) can be evaluated with use of fresh human cadaveric spines. The information gained from cadaveric testing may be supplemented by the finite element model-based analyses. Upon the successful completion of these tests, studies that make use of an animal model are performed to assess the structure, function, histology, and biomechanics of the device in situ and as a final step before clinical investigations are initiated. The protocols that are presently being used for the testing of spinal devices reflect the basic and applied research experience of the last three decades in the field of orthopaedic biomechanics in general and the spine in particular. The innovation within the spinal implant industry (e.g., fusion devices in the past versus motion-preservation devices at present) suggests that test protocols represent a dynamic process that must keep pace with changing expectations. Apart from randomized clinical trials, no single test can fully evaluate all of the characteristics of a device. Due to the inherent limitations of each test, data must be viewed in a proper context. Finally, a case is made for the medical community to converge toward standardized test protocols that will enable us to compare the vast number of currently available devices, whether on the market or still under development, in a systematic, laboratory-independent manner.

Animals↗

Effects of charité artificial disc on the implanted and adjacent spinal segments mechanics using a hybrid testing protocol.

STUDY DESIGN: Finite element model of L3-S1 segment and confirmatory cadaveric testing were used to investigate the biomechanical effects of a mobile core type artificial disc (Charité artificial disc; DePuy Spine, Raynham, MA) on the lumbar spine. OBJECTIVE: To determine the effects of the Charité artificial disc across the implanted and adjacent segments. SUMMARY OF BACKGROUND DATA: Biomechanical studies of artificial discs that quantify parameters, like the load sharing and stresses, are sparse in the literature, especially for mobile-type core artificial disc designs. In addition, there is no standard protocol for studying the adjacent segmental effects of such implants. METHODS: Human osteo-ligamentous spines (L1-S1) were tested before and after L5-S1 Charité artificial disc placement. The data were used to validate further an intact 3-dimensional (3-D) nonlinear L3-S1 finite element model. The model was subjected to 400-N axial compression and 10.6 Nm of flexion/extension pure moments (load control) or pure moments that produced the overall rotation of the L3-S1 Charité model equal to the intact case (hybrid approach). Resultant motion, load, and stress parameters were analyzed at the experimental and adjacent levels. RESULTS: Finite element model validation was achieved only with the load-controlled experiments. The hybrid approach, believed to be more clinically relevant, revealed that Charité artificial disc leads to motion increases in flexion (19%) and extension (44%) at the L5-S1 level. At the instrumented level, the decrease in the facet loads was less than at the adjacent levels; the corresponding decrease being 26% at L3-L4, 25% at L4-L5, and 13.4% at L5-S1 when compared to the intact. Intradiscal pressure changes in the L4-L5 and L3-L4 segments were minimal. Shear stresses at the Charité artificial disc-L5 endplate interface were higher than those at S1 interface. However, in the load control mode, the increase in facet loads in extension was approximately 14%, as compared to the intact case. CONCLUSIONS: The hybrid testing protocol is advocated because it better reproduces clinical observations in terms of motion following surgery, using pure moments. Using this approach, we found that the Charité artificial disc placement slightly increases motion at the implanted level, with a resultant increase in facet loading when compared to the adjacent segments, while the motions and loads decrease at the adjacent levels. However, in the load control mode that we believe is not that clinically relevant, there was a large increase in motion and a corresponding increase in facet loads, as compared to the intact.

Biomechanical Phenomena↗

In vitro biomechanical comparison of pedicle screws, sublaminar hooks, and sublaminar cables.

OBJECT: Three types of posterior thoracolumbar implants are in use today: pedicle screws, sublaminar titaniumcables, and sublaminar hooks. The authors conducted a biomechanical comparison of these three implants in human cadaveric spines. METHODS: Spine specimens (T5-12) were harvested, radiographically assessed for fractures or metastases, and their bone mineral density (BMD) was measured. Individual vertebrae were disarticulated and fitted with either pedicle screws, sublaminar cables, or bilateral claw hooks. The longitudinal component of each construct consisted of bilateral 10-cm rods connected with two cross-connectors. The vertebral body was embedded in cement, and the rods were affixed to a ball-and-socket apparatus for the application of a distraction force. The authors analyzed 1) 20 vertebrae implanted with screws; 2) 20 with hooks, and 3) 20 with cables. The maximum pullout (MPO) forces prior to failure (mean +/- standard deviation) for the screw, hook, and cable implants were 972 +/- 330, 802 +/- 356, and 654 +/- 248 N, respectively (p = 0.0375). Cables allowed significantly greater displacement (6.80 +/- 3.95 mm) prior to reaching the MPO force than hooks (3.73 +/- 1.42 mm) and screws (4.42 +/- 2.15 mm [p = 0.0108]). Eleven screw-implanted vertebrae failed because of screw pullout. All hook-and-cable-implanted vertebrae failed because of pedicle, middle column, or laminar fracture. CONCLUSIONS: These findings suggest that screws possess the greatest pullout strength of the three fixation systems. Sublaminar cables are the least rigid of the three. When screw failure occurred, the mechanism was generally screw back-out, without vertebral fractures.

Adult↗

In vitro biomechanical studies of an anterior thoracolumbar implant.

After L1 corpectomy in T11-L3 human cadaveric spine, anterior thoracolumbar instrumentation with strut grafting restores spinal stability. T12-L2 angular rotation was measured in response to moments of 0.0, 1.5, 3.0, 4.5, and 6.0 Nm in flexion, extension, lateral bending, and axial rotation, respectively. The spines were tested: 1) intact; 2) after partial L1 corpectomy, grafting, and instrumentation (Profile plate, DePuy-AcroMed, Raynham, MA), with the wooden dowel graft screwed to the plate; 3) without graft screw fixation; and 4) after flexion-extension cyclic fatiguing for 5000 cycles at a load of +/-3.0 Nm. Before and after fatiguing, the instrumented spine was significantly (p <or= 0.05) stiffer than the intact spine in flexion, extension, and right and left lateral bending but not in axial rotation. There were no significant differences between the constructs with or without graft-to-plate fixation before or after fatigue. The instrumented spines were more rigid in bending away from the implant than bending toward the implant. Anterior spinal instrumentation with the Profile implant augments stiffness in the sagittal and coronal planes but not in the axial plane. Although graft-to-plate fixation may prevent graft migration into the canal, it does not contribute to spinal rigidity.

Biomechanical Phenomena↗

Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?

BACKGROUND CONTEXT: Surgeons are hesitant to mix components made of differing metal classes for fear of galvanic corrosion complications. However, in vitro studies have failed to show a significant potential for galvanic corrosion between titanium and stainless steel, the two primary metallic alloys used for spinal implants. Galvanic corrosion resulting from metal mixing has not been described in the literature for spinal implant systems. PURPOSE: To determine whether galvanic potential significantly affects in vitro corrosion of titanium and stainless steel spinal implant components during cyclical compression bending. STUDY DESIGN/SETTING: Bilateral spinal implant constructs consisting of pedicle screws, slotted connectors, 6.35-mm diameter rods and a transverse rod connector assembled in polyethylene test blocks were tested in vitro. Two constructs had stainless steel rods with mixed stainless steel (SS-SS) and titanium (SS-Ti) components, and two constructs had titanium rods with mixed stainless steel (Ti-SS) and titanium (Ti-Ti) components. METHODS: Each construct was immersed in phosphate-buffered saline (pH 7.4) at 37 C and tested in cyclic compression bending using a sinusoidal load-controlling function with a peak load of 300 N and a frequency of 5 Hz until a level of 5 million cycles was reached. The samples were then removed and analyzed visually for evidence of corrosion. In addition, scanning electron microscopy (SEM) and energy dispersive spectrometry (EDS) were used to evaluate the extent of corrosion at the interconnections. RESULTS: None of the constructs failed during testing. Gross observation of the implant components after disassembly revealed that no corrosion had occurred on the surface of the implants that had not been in contact with another component. The Ti-Ti interfaces showed some minor signs of corrosion only detectable using SEM and EDS. The greatest amount of corrosion occurred at the SS-SS interfaces and was qualitatively less at the SS-Ti and Ti-SS interfaces. CONCLUSIONS: The results from this study indicate that when loaded dynamically in saline, stainless steel implant components have a greater susceptibility to corrosion than titanium. Furthermore, the galvanic potential between the dissimilar metals does not cause a discernible effect on the corrosion of either. Although the mixture of titanium alloy with stainless steel is not advocated, the results of this study suggest that galvanic corrosion is less pronounced in SS-Ti mixed interfaces than in all stainless steel constructs.

Alloys↗

A pilot study to evaluate the effectiveness of small intestinal submucosa used to repair spinal ligaments in the goat.

BACKGROUND CONTEXT: Destabilization of the lumbar spine results from sacrifice of the anterior longitudinal ligament and disc when removed for graft or cage placement. In a similar fashion, transection of the interspinous ligament during surgical approaches to the posterior spine may result in segmental instability. Such instability can cause abnormal motion or implant migration resulting in a higher incidence of pseudarthrosis. Small intestinal submucosa (SIS) is a naturally occurring extracellular collagen-based matrix, which is derived from porcine small intestine. SIS contains cytokines and growth factors and has been shown to act as a resorbable scaffold in vivo that promotes host soft tissue regeneration with little scar tissue formation. SIS can be manufactured in laminated sheets of various sizes and thicknesses for different indications. Successful applications of SIS in animals have included dural substitution, rotator cuff repair, vessel repair, abdominal and bladder wall repair, and others. However, SIS has not been investigated to determine its ability to facilitate regeneration of spinal ligaments. PURPOSE: The purpose of this pilot study was to evaluate the efficacy of SIS as a barrier to prevent interbody device migration, and to act as a scaffold for regeneration of the anterior longitudinal ligament (ALL) and posterior interspinous ligament (PISL) in a goat model. STUDY DESIGN/SETTING: The thoracolumbar spine of the goat was exposed surgically. After resection and removal of the ALL or PISL at alternating levels, either SIS was placed or no treatment was administered. New ligament formation and SIS resorption were monitored over a 12-week period. OUTCOME MEASURES: Plain film radiographs and histomorphometry were used to assess the progress of healing over a 12-week time period. METHODS: Four skeletally mature nubian-alpine crossbred goats were used in this study. Under general anesthesia, each T10 to L5 motion segment was exposed surgically. Both anterolateral and posterior approaches were performed simultaneously at each level. Anteriorly, alternating levels received either 1) anterior discectomy, sacrifice of ALL and placement of SIS (SIS group); 2) anterior discectomy, sacrifice of ALL and no SIS (surgical control group) or 3) no surgical intervention (nonoperative group). A solid interbody spacer was placed into the disc space after discectomy to deter spontaneous anterior interbody fusion. Posteriorly, alternating levels were treated with either 1) sacrifice of the PISL with placement of SIS (SIS group); 2) sacrifice of PISL and no SIS (surgical control group) or 3) no surgical intervention (nonoperative group). The SIS was secured to the adjacent superior and inferior spinous processes to create a tension-band effect. Animals were radiographed immediately postoperatively to confirm placement of interbody spacers and anchors and to serve as a baseline for monitoring interbody spacer positioning. After surgery, all animals were allowed unrestricted motion for 12 weeks. At the end of the 12-week period, animals were radiographed and euthanized. The lumbar spine was harvested en bloc and processed for decalcified histologic evaluation. The dorsal and ventral aspects of each motion segment were analyzed for signs of inflammation and scar tissue formation, residual SIS and regenerated ALL or PISL. RESULTS: All animals tolerated the surgical procedure well, and there were no intraoperative or anesthesia-related complications. Twelve-week radiographs showed some evidence of ventral migration of the interbody spacers in several animals. Fifty percent (two of four) of spacers in surgical control group levels had migrated more than 10 mm (resulting in complete migration out of the disc space), whereas no spacers migrated completely out of levels with SIS placed. Gross analysis at necropsy indicated iatrogenic scar formation at operated levels, the degree of which was not different from surgical control group to SIS levels. Histologic evaluation of areas where the ALL had been removed indicated formation of organized fibrilar collagenous tissue that spanned the disc space at some levels where the SIS was placed. In some cases, the newly formed tissue was approximately the thickness of the ALL at the nonoperative group levels. The newly formed collagenous tissue was accompanied by sparse focal areas of inflammation, with small fragments of residual SIS at some levels. At surgical control group levels, there was a varying degree of connective tissue that ranged from moderately organized to randomly oriented with no significant signs of inflammation. Similarly, histologic analysis of some levels where SIS was placed posteriorly showed formation of organized collagenous tissues where the PISL had been removed. CONCLUSIONS: In this model, the SIS patch was sufficient to prevent acute ventral migration of interbody spacers from the disc space. The extent of long-term healing and new tissue formation in the SIS group indicates that it may be efficacious as a reparative intervention for transected ligaments in the spine. Most SIS specimens showed formation of organized collagenous tissue, indicating a long-term potential for ligament formation. However, in this model, 12 weeks of postoperative healing is insufficient to assess the full potential of SIS as a spinal ligament repair. Further research that follows the healing process to a longer time point postoperatively may be necessary to fully understand the potential of SIS as a resorbable scaffold for tissue replacement.

Absorbable Implants↗