Hatem Alkadhi

Publications and source records attributed to Hatem Alkadhi.

At least 19 recordsLinked to original sources

Accuracy of 64-slice CT angiography for the detection of functionally relevant coronary stenoses as assessed with myocardial perfusion SPECT.

PURPOSE: CT angiography (CTA) offers a valuable alternative for the diagnosis of CAD but its value in the detection of functionally relevant coronary stenoses remains uncertain. We prospectively compared the accuracy of 64-slice CTA with that of myocardial perfusion imaging (MPI) using (99m)Tc-tetrofosmin-SPECT as the gold standard for the detection of functionally relevant coronary artery disease (CAD). METHODS: MPI and 64-slice CT were performed in 100 consecutive patients. CTA lesions were analysed quantitatively and area stenoses > or =50% and > or =75% were compared with the MPI findings. RESULTS: In 23 patients, MPI perfusion defects were found (12 reversible, 13 fixed). A total of 399 coronary arteries and 1,386 segments was analysed. Eighty-four segments (6.1%) in 23 coronary arteries (5.8%) of nine patients (9.0%) were excluded owing to insufficient image quality. In the remaining 1,302 segments, quantitative CTA revealed stenoses > or =50% in 57 of 376 coronary arteries (15.2%) and stenoses > or =75% in 32 (8.5%) coronary arteries. Using a cut-off at > or =75% area stenosis, CTA yielded the following sensitivity, specificity, negative (NPV) and positive predictive value (PPV), and accuracy for the detection of any (fixed and reversible) MPI defect: by patient, 75%, 90%, 93%, 68% and 87%, respectively; by artery, 76%, 95%, 99%, 50% and 94%, respectively. CONCLUSION: Sixty-four-slice CTA is a reliable tool to rule out functionally relevant CAD in a non-selected population with an intermediate pretest likelihood of disease. However, an abnormal CTA is a poor predictor of ischaemia.

Adult↗

Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography.

We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 +/- 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer's values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 +/- 0.39 mm versus 2.49 +/- 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 +/- 6.2 mm, correlating well with CT (18.5 +/- 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 +/- 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA.

Adult↗

Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT.

This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding.

Acute Disease↗

In-vivo flow simulation in coronary arteries based on computed tomography datasets: feasibility and initial results.

The purpose of this paper was to non-invasively assess hemodynamic parameters such as mass flow, wall shear stress (WSS), and wall pressure with computational fluid dynamics (CFD) in coronary arteries using patient-specific data from computed tomography (CT) angiography. Five patients (two without atherosclerosis, three with atherosclerosis) underwent retrospectively electrocardiogram (ECG) gated 16-detector row CT using ECG-pulsing and geometric models of coronary arteries were reconstructed for CFD analysis. Blood flow was considered laminar, incompressible, Newtonian, and pulsatile. The mass flow, WSS, and wall pressure were quantified and flow patterns were visualized. The wall pressure continuously decreased towards distal segments and showed pressure drops in stenotic segments. In coronary segments without atherosclerotic wall changes, WSS remained low, even during phases of high flow velocity, whereas in atherosclerotic vessels, the WSS was elevated already at low flow velocities. Stenoses and post-stenotic dilatations led to flow acceleration and rapid deceleration, respectively, including a distortion of flow. Areas of high WSS and high flow velocities were found adjacent to plaques, with values correlating with the degree of stenosis. CFD provided detailed mass flow measurements. CFD analysis is feasible in normal and atherosclerotic coronary arteries and provides the rationale for further investigation of the links between hemodynamic parameters and the significance of coronary stenoses.

Aged↗

Accuracy of dual-source CT coronary angiography: First experience in a high pre-test probability population without heart rate control.

The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1+/-11.3 years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14+/-9 days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter > or =1.5 mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3+/-3.9 kg/m2 (range 22.4-36.3 kg/m2), mean heart rate during CT was 70.3+/-14.2 bpm (range 47-102 bpm), and mean Agatston score was 821+/-904 (range 0-3,110). Image quality was diagnostic (scores 1-3) in 98.6% (414/420) of segments (mean image quality score 1.68+/-0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control.

Adult↗

Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality.

PURPOSE: To evaluate prospectively the effect of average heart rate and heart rate variability on image quality at 64-section computed tomographic (CT) coronary angiography. MATERIALS AND METHODS: The study protocol had local ethics committee approval; written informed consent was obtained. There were 125 patients (45 women, 80 men; mean age, 59.9 years +/- 12.9 [standard deviation]; 79 receiving beta-blockers) who underwent 64-section CT coronary angiography with retrospective electrocardiographic gating. Data sets were reconstructed in 5% steps from 20% to 80% of R-R interval. Heart rate variability was calculated as 1 standard deviation from mean rate during scanning. Two observers rated image quality of each coronary segment at least 1.5-mm diameter (1 = no motion artifacts, 5 = not evaluative). Repeated analysis of variance measurements were performed to evaluate quantitative parameters. Pearson correlation analysis was performed to compare image quality in each patient with average heart rate and heart rate variability. RESULTS: Average heart rate was 63.3 beats per minute +/- 13.1, with variability of 3.2 beats per minute +/- 2.1. Diagnostic image quality (score < or = 3) was attained in 1821 of 1836 segments at the best reconstruction interval. There was no correlation between mean heart rate and image quality for all segments of the right coronary and left anterior descending arteries, but there was a significant correlation for left circumflex artery (r = 0.33, P < .05). Heart rate variability was correlated with image quality overall (r = 0.75, P < .001) and for each coronary artery. Heart rate was less variable and image quality was better (P < .05) in patients receiving beta-blockers. Best image quality was obtained in diastole with heart rate less than 80 beats per minute and in systole with faster heart rate. CONCLUSION: Coronary angiography with 64-section CT provides diagnostic image quality within a wide range of heart rates. Reducing average heart rate and heart rate variability is beneficial for reducing artifacts.

Adult↗

Use of coronary calcium score scans from stand-alone multislice computed tomography for attenuation correction of myocardial perfusion SPECT.

PURPOSE: To evaluate the use of CT attenuation maps, generated from coronary calcium scoring (CCS) scans at in- and expiration with a 64-slice CT scanner, for attenuation correction (AC) of myocardial perfusion SPECT images. METHODS: Thirty-two consecutive patients underwent( 99m)Tc-tetrofosmin gated adenosine stress/rest SPECT scan on an Infinia Hawkeye SPECT-CT device (GE Medical Systems) followed by CCS and CT angiography on a 64-slice CT. AC of the iteratively reconstructed images was performed with AC maps obtained: (a) from the "Hawkeye" low-resolution X-ray CT facility attached to the Infinia camera (IRAC); (b) from the CCS scan acquired on a 64-slice CT scanner during maximal inspiration (AC(INSP)) and (c) during normal expiration (AC(EXP)). Automatically determined uptake values of stress scans (QPS, Cedars Medical Sinai) from AC(INSP) and AC(EXP) were compared with IRAC. Agatston score (AS) values using AC(INSP)versus AC(EXP) were also compared. RESULTS: AC(INSP) and AC(EXP) resulted in identical findings versus IRAC by visual analysis. A good correlation for uptake values between IRAC and AC(INSP) was found (apex, r=0.92; anterior, r=0.85; septal, r=0.91; lateral, r=0.86; inferior, r=0.90; all p<0.0001). The correlation was even closer between IRAC and AC(EXP) (apex, r=0.97; anterior, r=0.91; septal, r=0.94; lateral, r=0.92; inferior, r=0.97; all p<0.0001). The mean AS during inspiration (319+/-737) and expiration(317+/-778) was comparable (p=NS). CONCLUSION: Attenuation maps from CCS allow accurate AC of SPECT MPI images. AC(EXP) proved superior to AC(INSP), suggesting that in hybrid scans CCS may be performed during normal expiration to allow its additional use for AC of SPECT MPI.

Adult↗

Coronary artery imaging with 64-slice computed tomography from cardiac surgical perspective.

INTRODUCTION: 64-Slice computed tomography (CT) has been introduced with high expectations. This study illustrates the value of 64-slice CT for the diagnosis of significant coronary artery stenoses when images are analysed by cardiovascular surgeons. METHODS: Fifty patients (39 males, 11 females) underwent invasive coronary angiography and 64-slice CT. In these patients, 40 had coronary artery disease and 10 patients had valvular disease. Evaluation of right coronary artery (RCA), left main (LM), left anterior descending artery (LAD), diagonal branch 1 (D1), circumflex branch (CX), and 1st marginal branch was performed by two cardiovascular surgeons. All vessels with a diameter >/=1.5 mm were analysed and a lumen restriction of >50% was considered a significant stenosis. CT image quality was classified as excellent, reduced but still diagnostic, and not assessable. Invasive coronary angiography was taken as gold standard for calculations of diagnostic accuracy. RESULTS: Mean heart rate during CT scan was 65+/-11 beats per minute (bpm). Image quality of 92% (506/550) of all segments was rated as excellent, 5% (27/550) were rated as being of reduced quality but still diagnostic, and 3% (17/550) were considered not assessable. The sensitivity for diagnosing a significant stenosis with CT when including all reliably evaluated segments was 93% (106/114), specificity was 97% (381/392), positive predictive value was 91% (106/117), and negative predictive value was 98% (381/389). CONCLUSION: 64-Slice CT provides a high diagnostic accuracy in assessing significant coronary artery stenosis. Nevertheless, still exist some disadvantages such as strong vessel wall calcifications reducing the reliability for image interpretation. At the moment, 64-slice CT should be used as a complementary imaging modality to invasive coronary angiography.

Aged↗

Aortic stenosis: comparative evaluation of 16-detector row CT and echocardiography.

PURPOSE: To prospectively evaluate whether planimetric measurements of aortic valve area (AVA) with 16-detector row computed tomography (CT) allow classification of aortic stenosis (AS). MATERIALS AND METHODS: The study had institutional review board approval; patients gave informed consent. Twenty patients (11 men, nine women; mean age, 63 years) with AS and 20 patients (10 men, 10 women; mean age, 65 years) without underwent transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and retrospectively electrocardiographically gated 16-detector row CT. Twenty CT data sets were reconstructed in 5% steps of R-R interval; data analysis was performed with four-dimensional software. Maximum AVA in systole planimetrically measured with CT (AVA(CT)) was compared with AVA planimetrically measured with TEE (AVA(TEE)), AVA calculated with the continuity equation and TTE (AVA(TTE)), and transvalvular pressure gradients determined with the Bernoulli equation and TTE. Correlations among AVA(CT), AVA(TTE), AVA(TEE), and transvalvular pressure gradients were tested with bivariate regression analysis; agreement between methods was assessed with the Bland-Altman method. RESULTS: In patients without AS, mean AVA(CT) was 3.56 cm2 +/- 0.66 and mean AVA(TEE) was 3.43 cm2 +/- 0.69. In patients with AS, mean AVA(CT) was 0.89 cm2 +/- 0.35; mean AVA(TEE), 0.86 cm2 +/- 0.35; and mean AVA(TTE), 0.83 cm2 +/- 0.33. Mean transvalvular pressure gradient was 51 mm Hg +/- 22. Significant correlations were present between AVA(CT) and AVA(TEE) (r = 0.99, P < .001), AVA(CT) and AVA(TTE) (r = 0.95, P < .001), and AVA(CT) and transvalvular pressure gradients (r = -0.74, P < .01). Mean differences were -0.08 cm2 (limits of agreement: -0.32, 0.16) for AVA(CT) versus AVA(TEE) and 0.06 cm2 (limits of agreement: -0.15, 0.26) for AVA(CT) versus AVA(TTE). CONCLUSION: Planimetric measurements of AVA with retrospectively electrocardiographically gated 16-detector row CT allow classification of AS that is similar to that achieved with measurements by using echocardiographic methods.

Aged↗

Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT.

The reconstruction intervals providing best image quality for non-invasive coronary angiography with 64-slice computed tomography (CT) were evaluated. Contrast-enhanced, retrospectively electrocardiography (ECG)-gated 64-slice CT coronary angiography was performed in 80 patients (47 male, 33 female; mean age 62.1+/-10.6 years). Thirteen data sets were reconstructed in 5% increments from 20 to 80% of the R-R interval. Depending on the average heart rate during scanning, patients were grouped as < 65 bpm (n = 49) and > or = 65 bpm (n = 31). Two blinded and independent readers assessed the image quality of each coronary segment with a diameter > or = 1.5 mm using the following scores: 1, no motion artifacts; 2, minor artifacts; 3, moderate artifacts; 4, severe artifacts; and 5, not evaluative. The average heart rate was 63.3 +/- 13.1 bpm (range 38-102). Acceptable image quality (scores 1-3) was achieved in 99.1% of all coronary segments (1,162/1,172; mean image quality score 1.55 +/- 0.77) in the best reconstruction interval. Best image quality was found at 60% and 65% of the R-R interval for all patients and for each heart rate subgroup, whereas motion artifacts occurred significantly more often (P < 0.01) at other reconstruction intervals. At heart rates < 65 bpm, acceptable image quality was found in all coronary segments at 60%. At heart rates > or = 65 bpm, the whole coronary artery tree could be visualized with acceptable image quality in 87% (27/31) of the patients at 60%, while ten segments in four patients were rated as non-diagnostic (scores 4-5) at any reconstruction interval. In conclusion, 64-slice CT coronary angiography provides best overall image quality in mid-diastole. At heart rates < 65 bpm, diagnostic image quality of all coronary segments can be obtained at a single reconstruction interval of 60%.

Adult↗

Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography.

The purpose of this study was to evaluate the influence of ejection fraction (EF), stroke volume (SV), heart rate, and cardiac output (CO) on coronary artery opacification with 64-slice computed tomography (CT). Sixty patients underwent, retrospectively, electrocardiography-gated 64-slice CT coronary angiography. Left ventricular EF, SV, and CO were calculated with semi-automated software. Attenuation values were measured and contrast-to-noise ratios (CNRs) were calculated in the proximal right coronary artery (RCA) and left main artery (LMA). Mean EF during scanning was 61.5+/-12.4%, SV was 63.2+/-15.6 ml, heart rate was 62.5+/-11.8 beats per minute (bpm), and CO was 3.88+/-1.06 l/min. There was no significant correlation between the EF and heart rate and the attenuation and CNR in either coronary artery. A significant negative correlation was found in both arteries between SV and attenuation (RCA r=-0.26, P<0.05; LMA r=-0.34, P<0.01) and between SV and CNR (RCA r=-0.26, P<0.05; LMA r=-0.26, P<0.05). Similarly, a significant negative correlation was found between the CO and attenuation (RCA r=-0.42, P<0.05; LMA r=-0.56, P<0.001) and between the CO and CNR (RCA r=-0.39, P<0.05; LMA r=-0.44, P<0.001). The actual hemodynamic status of the patient influences the coronary artery opacification with 64-slice CT, in that vessel opacification decreases as SV and CO increase.

Adult↗

CT angiography of peripheral arterial bypass grafts: Accuracy and time-effectiveness of quantitative image analysis with an automated software tool.

RATIONALE AND OBJECTIVES: Qualitative analysis of computed tomography (CT) angiography data often is limited by intra- and interobserver variability. The purpose of this study was to evaluate the time-effectiveness and accuracy of a quantitative CT angiography data analysis using automated software in comparison with qualitative axial and coronal CT image reading in patients with peripheral bypass grafts. MATERIALS AND METHODS: Twenty-eight patients with 33 saphenous bypass grafts underwent 4-channel (n = 21) and 16-channel (n = 7) CT angiography. Two readers evaluated in consensus the CT data qualitatively on axial and coronal reconstructions and with the software regarding the presence of graft stenoses, aneurysmal changes, and arteriovenous fistulas. The time for data analysis was taken and the accuracy was compared with the results from digital subtraction angiography (DSA). RESULTS: No significant difference was present between data analysis time using axial and coronal CT images (4.9 +/- 1.5 minutes) and when using the software tool (5.5 +/- 1.4 minutes). Good (kappa = 0.652) to excellent (kappa = 1.000) intermodality agreement was present between qualitative and quantitative CT analysis regarding graft-related abnormalities. Sensitivity and specificity for diagnosing stenoses, aneurysms, and fistula did not differ significantly (P > .025) between qualitative CT image reading and the automated software tool. CONCLUSIONS: CT angiography analysis of peripheral bypass grafts using an automated software tool is similar regarding time-effectiveness and accuracy when compared with qualitative CT data analysis on axial and coronal images. It may assist in determining the significance of an abnormality and can yield objective morphometric data of vessel calibers.

Algorithms↗

Thick maximum intensity projections for the assessment of left ventricular function with 64-slice computed tomography.

OBJECTIVE: The objective of this study was to assess the accuracy of thick maximum intensity projections (MIP) from computed tomography (CT) data sets mimicking projection images from biplane ventriculography for evaluation of left ventricular (LV) parameters. MATERIALS AND METHODS: Fifty-eight patients underwent 64-slice CT. Multiphase images were reconstructed in 10% steps of the RR interval. MIP images (70-mm thickness) of the contrast-enhanced LV in fixed 30 degrees right anterior oblique (RAO)/60 degrees left anterior oblique (LAO) and in adapted short-/long-axis planes were reconstructed. LV parameters were calculated using the area-length method formula. Three-dimensional assessment with semiautomated software served as reference standard. RESULTS: Use of thick MIP reconstructions had a high intermethod reliability (86-94%) compared with the 3-dimensional approach. Smaller measurement errors were found for thick MIP reconstructions in adapted short-/long-axis planes. A significant projection error (3.0%, P < 0.001) of thick MIP reconstructions was found using fixed 30 degrees RAO/60 degrees LAO compared with adapted short-/long-axis reconstructions. CONCLUSION: Thick MIP reconstructions with adapted short-/long-axis planes allow an accurate assessment of LV parameters compared with the established 3-dimensional method.

Adult↗

Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function.

UNLABELLED: Precise and reliable assessment of left ventricular (LV) function and dimensions is prognostically important in cardiac patients. As the integration of SPECT and multislice CT into hybrid scanners will promote the combined use of both techniques in the same patient, a comparison of the 2 methods is pertinent. We aimed at comparing LV dimensions, muscle mass, and function obtained by electrocardiographically gated 64-slice CT versus gated-SPECT. METHODS: Sixty patients (mean age, 64 +/- 8 y) referred for evaluation of coronary artery disease underwent 99mTc-tetrofosmin gated SPECT and 64-slice CT within 4 +/- 2 d. LV ejection fraction (LVEF), end-systolic volume (ESV), and end-diastolic volume (EDV) from CT were compared with SPECT. Additionally, LV muscle mass and quantitative regional wall motion were assessed in 20 patients with both methods. RESULTS: CT was in good agreement with SPECT for quantification of LVEF (r = 0.825), EDV (r = 0.898), and ESV (r = 0.956; all P < 0.0001). LVEF was 59% +/- 13% measured by SPECT and slightly higher but not significantly different by CT (60% +/- 12%; mean difference compared with SPECT, 1.1% +/- 1.7%; P = not significant). A systematic overestimation using CT for EDV (147 +/- 60 mL vs. 113 +/- 52 mL; mean difference, 33.5 +/- 23.1 mL) and ESV (63 +/- 55 mL vs. 53 +/- 49 mL; mean difference, 9.3 +/- 15.9 mL; P < 0.0001) was found compared with SPECT. A good correlation for muscle mass was found between the 2 methods (r = 0.868; P < 0.005). However, muscle mass calculated by SPECT was significantly lower compared with CT (127 +/- 24 g vs. 148 +/- 37 g; mean difference, 23.0 +/- 12.2 g; P < 0.001). The correlation for regional wall motion between the 2 methods was moderate (r = 0.648; P < 0.0001). CONCLUSION: LVEF and LV functional parameters as determined by 64-slice CT agree over a wide range of clinically relevant values with gated SPECT. However, interchangeable use of the 2 techniques should be avoided for LV volumes, muscle mass, and regional wall motion because of variances inherent to the different techniques.

Adult↗

Repeatability of cold pressor test-induced flow increase assessed with H(2)(15)O and PET.

UNLABELLED: The aim of this study was to evaluate the repeatability of endothelium-related myocardial blood flow (MBF) responses to cold pressor testing (CPT) as assessed by PET. METHODS: In 10 age-matched control subjects (26.6 +/- 3.4 y) and 10 tobacco smokers (24.9 +/- 3.3 y) MBF was assessed at rest and after repeated CPT (CPT1 and CPT2, 40 min apart) using PET with H(2)(15)O. CPT was performed by a 2-min immersion of the subject's foot in ice water. MBF values were corrected for cardiac workload (rate.pressure product), and the repeatability of CPT-related MBF values was assessed according to Bland and Altman. RESULTS: Corrected MBF at CPT1 and CPT2 were comparable in control subjects (1.79 +/- 0.37 vs. 1.70 +/- 0.35 mL/min/g; P = not significant [NS]) and in smokers (1.97 +/- 0.42 vs. 1.80 +/- 0.41 mL/min/g; P = NS). Repeatability coefficients in control subjects and smokers were 0.46 mL/min/g (27% of the mean MBF) and 0.51 mL/min/g (27%), respectively. MBF increased significantly after CPT in both groups but tended to be lower in smokers (P = 0.08). CONCLUSION: PET measured MBF combined with CPT is a feasible and repeatable method for the evaluation of endothelium-related changes of MBF.

Adult↗

Mitral regurgitation: quantification with 16-detector row CT--initial experience.

PURPOSE: To prospectively determine if retrospectively electrocardiographic (ECG)-gated multi-detector row computed tomography (CT) with a 16-detector row CT scanner can depict mitral regurgitation and enable quantification of the severity of the disease. MATERIALS AND METHODS: The study had institutional review board approval, and patients gave informed consent. Nineteen patients with mitral regurgitation (10 men, nine women; mean age, 66 years +/- 9 [standard deviation]; range, 41-83 years) and 25 patients without mitral regurgitation (14 men, 11 women; mean age, 68 years +/- 9; range, 43-83 years) as determined with transesophageal color Doppler echocardiography and ventriculography underwent retrospectively ECG-gated 16-detector row CT. Twenty CT data sets covering the entire mitral valve apparatus were reconstructed in 5% steps of the R-R interval for each patient, and data analysis was performed with four-dimensional software. Using planimetry, two readers measured in consensus the area of the regurgitant orifice during systole. These measurements were compared with semiquantitative data from transesophageal echocardiography and ventriculography by using Spearman rank order correlation coefficients. RESULTS: In the 25 patients without mitral regurgitation, no regurgitant orifice during systole could be detected with multi-detector row CT. In the 19 patients with mitral regurgitation, a regurgitant orifice could be visualized in all cases. The mean regurgitant orifice area at CT-45 mm(2) +/- 34 (range, 10-148 mm(2))-correlated significantly with the results at transesophageal echocardiography (r = 0.807, P < .001) and ventriculography (r = 0.922, P < .001). CONCLUSION: Planimetric measurements of the regurgitant orifice area at retrospectively ECG-gated 16-detector row CT enable quantification of mitral regurgitation.

Adult↗