A digital processing strategy to optimize hearing aid outputs directly.

A new amplification strategy (ADRO), based on 64 independently operating channels, was compared with a nine-channel wide dynamic range compression strategy (WDRC). Open-platform in-the-ear hearing instruments were configured either with ADRO or the manufacturer's WDRC strategy. Twenty-two subjects with mild to moderate hearing loss took home the ADRO or WDRC hearing aids. After three weeks' acclimatization, the aids were evaluated using monosyllables in quiet at 50 to 65 dB SPL and sentences in eight-talker babble. The acclimatization and evaluation were repeated in the second phase of the balanced reverse-block blind experimental design. The ADRO program showed a statistically significant mean advantage of 7.85% word score (95% confidence interval 3.19% to 12.51%; p = 0.002) and 6.41% phoneme score for the monosyllables in quiet (95% confidence interval 2.03% to 10.79%; p = 0.006). A statistically significant advantage of 7.25% was also found for the ADRO program in background noise (95% confidence interval 1.95% to 12.55%; p = 0.010). The results are consistent with earlier data for listeners with moderate to severe hearing loss.

Acoustic Stimulation↗

Improving speech intelligibility in background noise with an adaptive directional microphone.

Omnidirectional, supercardioid, and adaptive directional microphones (ADM) were evaluated in combination with the ADRO amplification scheme for eight participants with moderate sloping hearing losses. The ADM produced better speech perception scores than the other two microphones in all noise conditions. Participants performed the Hearing in Noise Test sentences at -4.5 dB SNR or better, which is similar to the level achievable with normal hearing. The Speech, Spatial and Qualities of Hearing Scale indicated no disadvantages of using the ADM relative to the omnidirectional microphone in real-life situations. The ADM was preferred over the omnidirectional microphone in 54% of situations, compared to 17% preferences for the omnidirectional microphone, and 29% no preference. The combination of the ADM to improve SNR, and ADRO to keep the signal output comfortable and audible provided near-normal hearing performance for people with moderate hearing loss. The ADM is the recommended microphone configuration for ADRO hearing aids.

Adult↗