Quasi-continuous and discrete confidence rating scales for observer performance studies: Effects on ROC analysis.

RATIONALE AND OBJECTIVES: To examine the effects of the number of categories in the rating scale used in an observer experiment on the results of ROC analysis by a simulation study. MATERIALS AND METHODS: We have previously evaluated the effects of computer-aided diagnosis on radiologists' characterization of malignant and benign breast masses in serial mammograms. The evaluation of the likelihood of malignancy was performed on a quasi-continuous (0-100 points) confidence rating scale. In this study, we simulated the use of discrete confidence rating scales with fewer number of categories and analyzed the results with receiver operating characteristic (ROC) methodology. The observers' estimates of the likelihood of malignancy were also mapped to BI-RADS assessments with five and seven categories and ROC analysis was performed. The area under the ROC curve and the partial area index obtained from ROC analysis of the different confidence rating scales were compared. RESULTS: The fitted ROC curves and the performance indices do not change significantly when the confidence rating scales were varied from 6 to 101 points if the estimated operating points obtained directly from the data are distributed relatively evenly over the entire range of true-positive fraction (TPF) and false-positive fraction (FPF). The mapping of the likelihood of malignancy observer data to the seven-category BI-RADS assessment scale allowed reliable ROC analysis, whereas mapping to the five-category BI-RADS scale could cause erratic ROC curve fitting because of the lack of operating points in the mid-range or failure in ROC curve fitting because of data degeneration for some observers. CONCLUSION: ROC analysis of discrete confidence rating scales with few but relatively evenly distributed data points over the entire FPF and TPF range is comparable to that of a quasi-continuous rating scale. However, ROC analysis of discrete confidence rating scales with few and unevenly distributed data points may cause unreliable estimations.

Breast Neoplasms↗

Mammographic density measured with quantitative computer-aided method: comparison with radiologists' estimates and BI-RADS categories.

PURPOSE: To retrospectively compare computer-aided mammographic density estimation (MDEST) with radiologist estimates of percentage density and Breast Imaging Reporting and Data System (BI-RADS) density classification. MATERIALS AND METHODS: Institutional Review Board approval was obtained for this HIPAA-compliant study; patient informed consent requirements were waived. A fully automated MDEST computer program was used to measure breast density on digitized mammograms in 65 women (mean age, 53 years; range, 24-89 years). Pixel gray levels in detected breast borders were analyzed, and dense areas were segmented. Percentage density was calculated by dividing the number of dense pixels by the total number of pixels within the borders. Seven breast radiologists (five trained with MDEST, two not trained) prospectively assigned qualitative BI-RADS density categories and visually estimated percentage density on 260 mammograms. Qualitative BI-RADS assessments were compared with new quantitative BI-RADS standards. The reference standard density for this study was established by allowing the five trained radiologists to manipulate the MDEST gray-level thresholds, which segmented mammograms into dense and nondense areas. Statistical tests performed include Pearson correlation coefficients, Bland-Altman agreement method, kappa statistics, and unpaired t tests. RESULTS: There was a close correlation between the reference standard and radiologist-estimated density (R = 0.90-0.95) and MDEST density (R = 0.89). Untrained radiologists overestimated percentage density by an average of 37%, versus 6% for trained radiologists (P < .001). MDEST showed better agreement with the reference standard (average overestimate, 1%; range, -15% to +18%). MDEST correlated better with percentage density than with qualitative BI-RADS categories. There were large overlaps and ranges of percentage density in qualitative BI-RADS categories 2-4. Qualitative BI-RADS categories correlated poorly with new quantitative BI-RADS categories, and 16 (6%) of 260 views were erroneously classified by MDEST. CONCLUSION: MDEST compared favorably with radiologist estimates of percentage density and is more reproducible than radiologist estimates when qualitative BI-RADS density categories are used. Qualitative and quantitative BI-RADS density assessments differed markedly.

Adult↗

Breast masses: computer-aided diagnosis with serial mammograms.

PURPOSE: To retrospectively evaluate effects of computer-aided diagnosis (CAD) involving an interval change classifier (which uses interval change information extracted from prior and current mammograms and estimates a malignancy rating) on radiologists' accuracy in characterizing masses on two-view serial mammograms as malignant or benign. MATERIALS AND METHODS: The data collection protocol had institutional review board approval. Patient informed consent was waived for this HIPAA-compliant retrospective study. Ninety temporal pairs of two-view serial mammograms (depicting 47 malignant and 43 benign biopsy-proved masses) were obtained from 68 patient files and were digitized. Biopsy was the reference standard. Eight Mammography Quality Standards Act of 1992-accredited radiologists and two breast imaging fellows assessed digitized two-view temporal pairs (in preselected regions of interest only) by estimating likelihood of malignancy and Breast Imaging Reporting and Data System (BI-RADS) category without and with CAD. Observers' rating data were analyzed with Dorfman-Berbaum-Metz (DBM) multireader multicase method. Statistical significance of differences was estimated with the DBM method and Student two-tailed paired t test. RESULTS: Average area under the receiver operating characteristic curve for likelihood of malignancy across the 10 observers was 0.83 (range, 0.74-0.88) without CAD and improved to 0.87 (range, 0.80-0.92) with CAD (P < .05). The average partial area index above a sensitivity of 0.90 for likelihood of malignancy was 0.35 (range, 0.13-0.54) without CAD and 0.49 (range, 0.18-0.73) with CAD--a nonsignificant improvement (P = .11). For BI-RADS assessment, it was estimated that with CAD, six radiologists would correctly recommend additional biopsies for malignant masses (range, 4.3%-10.6%) and five would correctly recommend reduction of biopsy (ie, fewer biopsies) for benign masses (range, 2.3%-9.3%). However, five radiologists would incorrectly recommend additional biopsy for benign masses (range, 2.3%-14.0%), and one would incorrectly recommend reduction of biopsy (4.3%). CONCLUSION: CAD involving interval change analysis of preselected regions of interest can significantly improve radiologists' accuracy in classifying masses on digitized screen-film mammograms as malignant or benign.

Adult↗

Advances in computer-aided diagnosis for breast cancer.

PURPOSE OF REVIEW: Computer-aided diagnosis (CAD) is a technology used for the detection and characterization of cancer. Although CAD is not limited to a single type of cancer, a large number of CAD systems to date have been designed and used for breast cancer. The aim of this review is to discuss the current state of the CAD systems for breast-cancer diagnosis, their application as a second reader in clinical practice, and studies that have evaluated the effect of CAD on radiologists' performance. RECENT FINDINGS: A large number of CAD applications are being developed for different imaging modalities. Owing to commercially available Food and Drug Administration (FDA) approved systems, the main clinical use of CAD to date is for screen-film mammography. Many studies have shown that CAD improves radiologists' performance. A large number of academic institutions have devoted a substantial research effort to developing CAD methods. SUMMARY: CAD systems will play an increasingly important role in the clinic as a second reader. Clinical trials have shown that CAD can improve the accuracy of breast-cancer detection. Preclinical studies have demonstrated the potential of CAD to improve the classification of malignant and benign lesions. An increased number of CAD systems are being developed for different breast-imaging modalities.

Breast Neoplasms↗

Computer-aided diagnosis of pulmonary nodules on CT scans: segmentation and classification using 3D active contours.

We are developing a computer-aided diagnosis (CAD) system to classify malignant and benign lung nodules found on CT scans. A fully automated system was designed to segment the nodule from its surrounding structured background in a local volume of interest (VOI) and to extract image features for classification. Image segmentation was performed with a three-dimensional (3D) active contour (AC) method. A data set of 96 lung nodules (44 malignant, 52 benign) from 58 patients was used in this study. The 3D AC model is based on two-dimensional AC with the addition of three new energy components to take advantage of 3D information: (1) 3D gradient, which guides the active contour to seek the object surface, (2) 3D curvature, which imposes a smoothness constraint in the z direction, and (3) mask energy, which penalizes contours that grow beyond the pleura or thoracic wall. The search for the best energy weights in the 3D AC model was guided by a simplex optimization method. Morphological and gray-level features were extracted from the segmented nodule. The rubber band straightening transform (RBST) was applied to the shell of voxels surrounding the nodule. Texture features based on run-length statistics were extracted from the RBST image. A linear discriminant analysis classifier with stepwise feature selection was designed using a second simplex optimization to select the most effective features. Leave-one-case-out resampling was used to train and test the CAD system. The system achieved a test area under the receiver operating characteristic curve (A(z)) of 0.83 +/- 0.04. Our preliminary results indicate that use of the 3D AC model and the 3D texture features surrounding the nodule is a promising approach to the segmentation and classification of lung nodules with CAD. The segmentation performance of the 3D AC model trained with our data set was evaluated with 23 nodules available in the Lung Image Database Consortium (LIDC). The lung nodule volumes segmented by the 3D AC model for best classification were generally larger than those outlined by the LIDC radiologists using visual judgment of nodule boundaries.

Biopsy↗

Joint two-view information for computerized detection of microcalcifications on mammograms.

We are developing new techniques to improve the accuracy of computerized microcalcification detection by using the joint two-view information on craniocaudal (CC) and mediolateral-oblique (MLO) views. After cluster candidates were detected using a single-view detection technique, candidates on CC and MLO views were paired using their radial distances from the nipple. Candidate pairs were classified with a similarity classifier that used the joint information from both views. Each cluster candidate was also characterized by its single-view features. The outputs of the similarity classifier and the single-view classifier were fused and the cluster candidate was classified as a true microcalcification cluster or a false-positive (FP) using the fused two-view information. A data set of 116 pairs of mammograms containing microcalcification clusters and 203 pairs of normal images from the University of South Florida (USF) public database was used for training the two-view detection algorithm. The trained method was tested on an independent test set of 167 pairs of mammograms, which contained 71 normal pairs and 96 pairs with microcalcification clusters collected at the University of Michigan (UM). The similarity classifier had a very low FP rate for the test set at low and medium levels of sensitivity. However, the highest mammogram-based sensitivity that could be reached by the similarity classifier was 69%. The single-view classifier had a higher FP rate compared to the similarity classifier, but it could reach a maximum mammogram-based sensitivity of 93%. The fusion method combined the scores of these two classifiers so that the number of FPs was substantially reduced at relatively low and medium sensitivities, and a relatively high maximum sensitivity was maintained. For the malignant microcalcification clusters, at a mammogram-based sensitivity of 80%, the FP rates were 0.18 and 0.35 with the two-view fusion and single-view detection methods, respectively. When the training and test sets were switched, a similar improvement was obtained, except that both the fusion and single-view detection methods had superior test performances on the USF data set than those on the UM data set. Our results indicate that correspondence of cluster candidates on two different views provides valuable additional information for distinguishing FPs from true microcalcification clusters.

Breast↗

Computer aided detection of clusters of microcalcifications on full field digital mammograms.

We are developing a computer-aided detection (CAD) system to identify microcalcification clusters (MCCs) automatically on full field digital mammograms (FFDMs). The CAD system includes six stages: preprocessing; image enhancement; segmentation of microcalcification candidates; false positive (FP) reduction for individual microcalcifications; regional clustering; and FP reduction for clustered microcalcifications. At the stage of FP reduction for individual microcalcifications, a truncated sum-of-squares error function was used to improve the efficiency and robustness of the training of an artificial neural network in our CAD system for FFDMs. At the stage of FP reduction for clustered microcalcifications, morphological features and features derived from the artificial neural network outputs were extracted from each cluster. Stepwise linear discriminant analysis (LDA) was used to select the features. An LDA classifier was then used to differentiate clustered microcalcifications from FPs. A data set of 96 cases with 192 images was collected at the University of Michigan. This data set contained 96 MCCs, of which 28 clusters were proven by biopsy to be malignant and 68 were proven to be benign. The data set was separated into two independent data sets for training and testing of the CAD system in a cross-validation scheme. When one data set was used to train and validate the convolution neural network (CNN) in our CAD system, the other data set was used to evaluate the detection performance. With the use of a truncated error metric, the training of CNN could be accelerated and the classification performance was improved. The CNN in combination with an LDA classifier could substantially reduce FPs with a small tradeoff in sensitivity. By using the free-response receiver operating characteristic methodology, it was found that our CAD system can achieve a cluster-based sensitivity of 70, 80, and 90 % at 0.21, 0.61, and 1.49 FPs/image, respectively. For case-based performance evaluation, a sensitivity of 70, 80, and 90 % can be achieved at 0.07, 0.17, and 0.65 FPs/image, respectively. We also used a data set of 216 mammograms negative for clustered microcalcifications to further estimate the FP rate of our CAD system. The corresponding FP rates were 0.15, 0.31, and 0.86 FPs/image for cluster-based detection when negative mammograms were used for estimation of FP rates.

Algorithms↗

Accuracy of the CT numbers of simulated lung nodules imaged with multi-detector CT scanners.

A study was performed to determine the accuracies and reproducibilities of the CT numbers of simulated lung nodules imaged with multi-detector CT scanners. The nodules were simulated by spherical balls of three diameters (4.8, 9.5, and 16 mm) and two compositions (50 and 100 mg/cc CaCO3 in water-equivalent plastic). All were scanned in a liquid-water-filled container at the center of a water-equivalent-plastic phantom and in air cavities within the same phantom using GE multi-detector CT scanners. The nodules were also scanned within simulated lung regions in an anthropomorphic thorax section phantom that was bolused on both sides with water-equivalent slabs. Results were compared for three scanning protocols--the protocol for the National Lung Screening Trial (NLST), the protocol for the Lung Tissue Research Consortium (LTRC) study, and a high resolution (small pitch, thin slice and small scan interval) higher dose "gold standard" protocol. Scans were repeated three times with each protocol to assess reproducibility. The CT numbers of the nodules in water were found to be nearly independent of nodule size. However, the presence and the size of an air cavity surrounding a nodule had a significant effect (e.g., the CT number of a 50 mg/cc nodule was 64 HU in water, 37 HU in a 1.8 cm diameter air cavity, and 19 HU in a 4.4 cm diameter air cavity). This variability of CT number with size of air cavity may affect the results of the LTRC study in which patients are scanned at both full inspiration and full expiration. The CT numbers of the 9.5 and 16 mm diameter nodules within the anthropomorphic phantom were highly reproducible (average standard deviations of 2 HU or less) for all protocols. On the other hand, both accuracy and reproducibility were significantly degraded for the 4.8 mm diameter nodules, especially for the NLST (2.5 mm thickness, 2 mm slice interval) technique. Use of thinner slice (1.25 mm) and slice interval (1.25 mm) scans that can be reconstructed retrospectively from the multi-detector helical CT projection data of the standard NLST protocol yield CT numbers for the 4.8 mm diameter nodules that are more accurate and reproducible than those of the standard NLST technique. In general, the CT numbers of the nodules were found to be lower at positions near the centers of the lungs and near the spine, which is probably due to increased beam hardening in those regions. Also, larger nodules were found to have higher CT numbers than smaller nodules, consistent with results obtained on early single slice GE CT scanners. Until manufacturers develop quantitative CT scanners with improved x-ray beam hardening and scatter corrections, it is recommended that reference phantoms be employed to more accurately assess the calcium contents of patient lung nodules in screening and tissue characterization studies and in eventual computer-aided detection and diagnosis applications.

Algorithms↗

A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis.

Digital tomosynthesis mammography (DTM) is a promising new modality for breast cancer detection. In DTM, projection-view images are acquired at a limited number of angles over a limited angular range and the imaged volume is reconstructed from the two-dimensional projections, thus providing three-dimensional structural information of the breast tissue. In this work, we investigated three representative reconstruction methods for this limited-angle cone-beam tomographic problem, including the backprojection (BP) method, the simultaneous algebraic reconstruction technique (SART) and the maximum likelihood method with the convex algorithm (ML-convex). The SART and ML-convex methods were both initialized with BP results to achieve efficient reconstruction. A second generation GE prototype tomosynthesis mammography system with a stationary digital detector was used for image acquisition. Projection-view images were acquired from 21 angles in 3 degrees increments over a +/- 30 degrees angular range. We used an American College of Radiology phantom and designed three additional phantoms to evaluate the image quality and reconstruction artifacts. In addition to visual comparison of the reconstructed images of different phantom sets, we employed the contrast-to-noise ratio (CNR), a line profile of features, an artifact spread function (ASF), a relative noise power spectrum (NPS), and a line object spread function (LOSF) to quantitatively evaluate the reconstruction results. It was found that for the phantoms with homogeneous background, the BP method resulted in less noisy tomosynthesized images and higher CNR values for masses than the SART and ML-convex methods. However, the two iterative methods provided greater contrast enhancement for both masses and calcification, sharper LOSF, and reduced interplane blurring and artifacts with better ASF behaviors for masses. For a contrast-detail phantom with heterogeneous tissue-mimicking background, the BP method had strong blurring artifacts along the x-ray source motion direction that obscured the contrast-detail objects, while the other two methods can remove the superimposed breast structures and significantly improve object conspicuity. With a properly selected relaxation parameter, the SART method with one iteration can provide tomosynthesized images comparable to those obtained from the ML-convex method with seven iterations, when BP results were used as initialization for both methods.

Algorithms↗

Dual system approach to computer-aided detection of breast masses on mammograms.

In this study, our purpose was to improve the performance of our mass detection system by using a new dual system approach which combines a computer-added detection (CAD) system optimized with "average" masses with another CAD system optimized with "subtle" masses. The two single CAD systems have similar image processing steps, which include prescreening, object segmentation, morphological and texture feature extraction, and false positive (FP) reduction by rule-based and linear discriminant analysis (LDA) classifiers. A feed-forward backpropagation artificial neural network was trained to merge the scores from the LDA classifiers in the two single CAD systems and differentiate true masses from normal tissue. For an unknown test mammogram, the two single CAD systems are applied to the image in parallel to detect suspicious objects. A total of three data sets were used for training and testing the systems. The first data set of 230 current mammograms, referred to as the average mass set, was collected from 115 patients. We also collected 264 mammograms, referred to as the subtle mass set, which were one to two years prior to the current exam from these patients. Both the average and the subtle mass sets were partitioned into two independent data sets in a cross validation training and testing scheme. A third data set containing 65 cases with 260 normal mammograms was used to estimate the FP marker rates during testing. When the single CAD system trained on the average mass set was applied to the test set with average masses, the FP marker rates were 2.2, 1.8, and 1.5 per image at the case-based sensitivities of 90%, 85%, and 80%, respectively. With the dual CAD system, the FP marker rates were reduced to 1.2, 0.9, and 0.7 per image, respectively, at the same case-based sensitivities. Statistically significant (p < 0.05) improvements on the free response receiver operating characteristic curves were observed when the dual system and the single system were compared using the test sets with either average masses or subtle masses.

Algorithms↗

Computer-aided detection system for breast masses on digital tomosynthesis mammograms: preliminary experience.

The purpose of the study was to design a computer-aided detection (CAD) system for breast mass detection on digital breast tomosynthesis (DBT) mammograms and to perform a preliminary evaluation of the performance of this system. Twenty-six patients were imaged with a prototype DBT system. Institutional review board approval and written informed patient consent were obtained. Use of the data set in this study was HIPAA compliant. The CAD system first screened the three-dimensional volume of the mass candidates by means of gradient-field analysis. Each mass candidate was segmented from the structured background, and its image features were extracted. A feature classifier was designed to differentiate true masses from normal tissues. The CAD system was trained and tested by using a leave-one-case-out method. The classifier calculated a mean area under the test receiver operating characteristic curve of 0.91 +/- 0.03 (standard error of mean). The CAD system achieved a sensitivity of 85%, with 2.2 false-positive objects per case. The results demonstrate the feasibility of the authors' approach to the development of a CAD system for DBT mammography.

Adult↗

Preliminary investigation of computer-aided detection of pulmonary embolism in three-dimensional computed tomography pulmonary angiography images.

RATIONALE AND OBJECTIVES: We sought to develop a computer-aided diagnosis (CAD) system for assisting radiologists in the detection of pulmonary embolism (PE) on computed tomography pulmonary angiographic (CTPA) images. MATERIALS AND METHODS: An adaptive three-dimensional (3D) voxel clustering method was developed based on expectation-maximization (EM) analysis to extract vessels from their surrounding tissues. Using a connected component analysis, the vessel tree was reconstructed by tracking the vessel and its branches in 3D space. The tracked vessels were prescreened for suspicious PE areas using a second EM analysis. A rule-based false-positive (FP) reduction method was designed to detect true PE based on the features of PE and vessels. In this preliminary study, 14 patients with positive CTPA for PE were studied. CT scans were performed at 1.25-mm collimation using a GE LightSpeed CT scanner; eight of these patients also had extensive lung parenchymal or pleural disease. One hundred sixty-three emboli were identified by two experienced thoracic radiologists. The emboli identified by the radiologists were used as the "gold standard." For each embolus, the percent diameter occlusion (clot) and conspicuity of embolus (rating of 1 to 5, with 5 being the most conspicuous) were visually estimated. One hundred one emboli were identified in the six patients without lung diseases; 57 were proximal to the subsegmental and 44 were subsegmental. For the eight patients with lung diseases, 62 emboli were identified, of which 37 were proximal to the subsegmental and 25 were subsegmental. A computer-detected volume was counted as true-positive when it overlapped with an embolus volume identified by the radiologists. RESULTS: In the cases without lung diseases, if the PE had a conspicuity of >2 and only partially (20%-80%) occluded the vessel, our method detected 92.0% of proximal emboli and 77.8% of subsegmental emboli, with an average of 18.3 FPs/case. In the cases containing extensive lung disease, 66.7% and 40.0% of the PEs were detected with an average of 11.4 FPs/case under the same conditions. For the 14 PE cases, 13 of them were diagnosed as positive PE cases (case sensitivity was 92.9%). CONCLUSION: This preliminary study indicates that our automated method is a promising approach to CAD of PE on CTPA. Further study is under way to collect a larger data set and to improve the detection accuracy for PE, especially those with <20% or >80% occlusion, and for very subtle PE. A fully developed CAD system is expected to provide a useful aid for PE detection on CTPA.

Angiography↗

Comparison of similarity measures for the task of template matching of masses on serial mammograms.

We conducted a study to evaluate the effectiveness of twelve different similarity measures in matching the corresponding masses on temporal pairs of current and prior mammograms. To perform this comparison we implemented each of the twelve similarity measures in the final stage of our multistage registration technique for automated registration of breast lesions in serial mammograms. The multistage technique consists of three stages. In the first stage an initial fan-shape search region was estimated on the prior mammogram based on the geometrical position of the mass on the current mammogram. In the second stage, the location of the fan-shape region was refined by warping, based on an affine transformation and simplex optimization. A new refined search region was defined on the prior mammogram. In the third stage, a search for the best match between the lesion template from the current mammogram and a structure on the prior mammogram was carried out within the search region. Our data set consisted of 318 temporal pairs. We performed three experiments, using a different subset of the 318 temporal pairs for each experiment. In each experiment we further tested how the performance of the similarity measures varied as the size of the search region increased or decreased. We evaluated the twelve similarity measures based on four criteria. The first criterion was the mean Euclidean distance, which was the average distance of the true location of the mass to the location detected by the similarity measure. The second criterion was the percentage of temporal pairs that were aligned so that 50% or more of the lesion area overlapped. The third criterion was the percentage of pairs that were aligned so that 75% or more of the lesion area overlapped. The fourth and final criterion was the robustness of the similarity measure. Our results showed that three of the similarity measures, Pearson's correlation, the cosine coefficient, and Goodman and Kruskal's Gamma coefficient, provide significantly higher accuracy (p < 0.05) in the task of matching the corresponding masses on serial mammograms than the other nine similarity measures.

Algorithms↗

ROC study of the effect of stereoscopic imaging on assessment of breast lesions.

An observer performance study was conducted to evaluate the usefulness of assessing breast lesion characteristics with stereomammography. Stereoscopic image pairs of 158 breast biopsy tissue specimens were acquired with a GE Senographe 2000D full field digital mammography system using a 1.8x magnification geometry. A phantom-shift method equivalent to a stereo shift angle of +/- 3 degrees relative to a central axis perpendicular to the detector was used. For each specimen, two pairs of stereo images were taken at approximately orthogonal orientations. The specimens contained either a mass, microcalcifications, both, or normal tissue. Based on pathological analysis, 39.9% of the specimens were found to contain malignancy. The digital specimen radiographs were displayed on a high resolution MegaScan CRT monitor driven by a DOME stereo display board using in-house developed software. Five MQSA radiologists participated as observers. Each observer read the 316 specimen stereo image pairs in a randomized order. For each case, the observer first read the monoscopic image and entered his/her confidence ratings on the presence of microcalcifications and/or masses, margin status, BI-RADS assessment, and the likelihood of malignancy. The corresponding stereoscopic images were then displayed on the same monitor and were viewed through stereoscopic LCD glasses. The observer was free to change the ratings in every category after stereoscopic reading. The ratings of the observers were analyzed by ROC methodology. For the 5 MQSA radiologists, the average Az value for estimation of the likelihood of malignancy of the lesions improved from 0.70 for monoscopic reading to 0.72 (p=0.04) after stereoscopic reading, and the average Az value for the presence of microcalcifications improved from 0.95 to 0.96 (p=0.02). The Az value for the presence of masses improved from 0.80 to 0.82 after stereoscopic reading, but the difference fell short of statistical significance (p=0.08). The visual assessment of margin clearance was found to have very low correlation with microscopic analysis with or without stereoscopic reading. This study demonstrates the potential of using stereomammography to improve the detection and characterization of mammographic lesions.

Biopsy↗

Computer-aided detection of lung nodules: false positive reduction using a 3D gradient field method and 3D ellipsoid fitting.

We are developing a computer-aided detection system to assist radiologists in the detection of lung nodules on thoracic computed tomography (CT) images. The purpose of this study was to improve the false-positive (FP) reduction stage of our algorithm by developing features that extract three-dimensional (3D) shape information from volumes of interest identified in the prescreening stage. We formulated 3D gradient field descriptors, and derived 19 gradient field features from their statistics. Six ellipsoid features were obtained by computing the lengths and the length ratios of the principal axes of an ellipsoid fitted to a segmented object. Both the gradient field features and the ellipsoid features were designed to distinguish spherical objects such as lung nodules from elongated objects such as vessels. The FP reduction performance in this new 25-dimensional feature space was compared to the performance in a 19-dimensional space that consisted of features extracted using previously developed methods. The performance in the 44-dimensional combined feature space was also evaluated. Linear discriminant analysis with stepwise feature selection was used for classification. The parameters used for feature selection were optimized using the simplex algorithm. Training and testing were performed using a leave-one-patient-out scheme. The FP reduction performances in different feature spaces were evaluated by using the area Az under the receiver operating characteristic curve and the number of FPs per CT section at a given sensitivity as accuracy measures. Our data set consisted of 82 CT scans (3551 axial sections) from 56 patients with section thickness ranging from 1.0 to 2.5 mm. Our prescreening algorithm detected 111 of the 116 solid nodules (nodule size: 3.0-30.6 mm) marked by experienced thoracic radiologists. The test Az values were 0.95 +/- 0.01, 0.88 +/- 0.02, and 0.94 +/- 0.01 in the new, previous, and combined feature spaces, respectively. The number of FPs per section at 80% sensitivity in these three feature spaces were 0.37, 1.61, and 0.34, respectively. The improvement in the test Az with the 25 new features was statistically significant (p<0.0001) compared to that with the previous 19 features alone.

Algorithms↗

Computer-aided detection of breast masses on full field digital mammograms.

We are developing a computer-aided detection (CAD) system for breast masses on full field digital mammographic (FFDM) images. To develop a CAD system that is independent of the FFDM manufacturer's proprietary preprocessing methods, we used the raw FFDM image as input and developed a multiresolution preprocessing scheme for image enhancement. A two-stage prescreening method that combines gradient field analysis with gray level information was developed to identify mass candidates on the processed images. The suspicious structure in each identified region was extracted by clustering-based region growing. Morphological and spatial gray-level dependence texture features were extracted for each suspicious object. Stepwise linear discriminant analysis (LDA) with simplex optimization was used to select the most useful features. Finally, rule-based and LDA classifiers were designed to differentiate masses from normal tissues. Two data sets were collected: a mass data set containing 110 cases of two-view mammograms with a total of 220 images, and a no-mass data set containing 90 cases of two-view mammograms with a total of 180 images. All cases were acquired with a GE Senographe 2000D FFDM system. The true locations of the masses were identified by an experienced radiologist. Free-response receiver operating characteristic analysis was used to evaluate the performance of the CAD system. It was found that our CAD system achieved a case-based sensitivity of 70%, 80%, and 90% at 0.72, 1.08, and 1.82 false positive (FP) marks/image on the mass data set. The FP rates on the no-mass data set were 0.85, 1.31, and 2.14 FP marks/image, respectively, at the corresponding sensitivities. This study demonstrated the usefulness of our CAD techniques for automated detection of masses on FFDM images.

Algorithms↗

Improvement in radiologists' characterization of malignant and benign breast masses on serial mammograms with computer-aided diagnosis: an ROC study.

PURPOSE: To evaluate the effects of computer-aided diagnosis (CAD) on radiologists' characterization of masses on serial mammograms. MATERIALS AND METHODS: Two hundred fifty-three temporal image pairs (138 malignant and 115 benign) obtained from 96 patients who had masses on serial mammograms were evaluated. The temporal pairs were formed by matching masses of the same view from two different examinations. Eight radiologists and two breast imaging fellows assessed the temporal pairs with and without computer aid. The classification of accuracy was quantified by using the area under receiver operating characteristic curve (A(z)). The statistical significance of the difference in A(z) between the different reading conditions was estimated with the Dorfman-Berbaum-Metz method for analysis of multireader multicase data and with the Student paired t test for analysis of observer-specific paired data. RESULTS: The average A(z) for radiologists' estimates of the likelihood of malignancy was 0.79 without CAD and improved to 0.84 with CAD. The improvement was statistically significant (P =.005). The corresponding average partial area index was 0.25 without CAD and improved to 0.37 with CAD. The improvement was also statistically significant (P =.005). On the basis of Breast Imaging Reporting and Data System assessments, it was estimated that with CAD, each radiologist, on average, reduced 0.7% (0.8 of 115) of unnecessary biopsies and correctly recommended 5.7% (7.8 of 138) of additional biopsies. CONCLUSION: CAD based on analysis of interval changes can significantly increase radiologists' accuracy in classification of masses and thereby may be useful in improving correct biopsy recommendations.

Adult↗