PubMed Health⌕ Search

Biomedical subjects

Heiko Hayen

Publications and source records attributed to Heiko Hayen.

13 recordsLinked to original sources

Separation and identification of phytosiderophores and their metal complexes in plants by zwitterionic hydrophilic interaction liquid chromatography coupled to electrospray ionization mass spectrometry.

A sensitive method for the separation of different phytosiderophores (PS) of the mugineic acid (MA) family, and the candidate ligand for intracellular metal transport in plants nicotianamine (NA), and respective metal complexes in plants by zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) coupled to electrospray ionization mass spectrometry (ESI-MS) is described. Separation of mugineic acid, 2'-deoxymugineic acid (DMA), 3-epi-hydroxymugineic acid (epi-HMA), nicotianamine, Fe(III)-DMA, Fe(III)-NA, M(II)-DMA, and M(II)-NA complexes (M(II)=Zn(II), Cu(II), Ni(II), and Fe(II)), was achieved within 22 min on the ZIC-HILIC column by using a gradient elution with a mobile phase consisting of ammonium acetate and acetonitrile at pH 7.3, at a flow rate of 0.15 mL/min. The on-line coupling to ESI-MS in the negative ionization mode enables the detection of these compounds in the micromol/L range, which is the relevant concentration range in real plant samples. DMA-complexes of Fe(III), Zn, and Cu in wheat root, and an NA-complex of Ni in Arabidopsis were detected and identified by the proposed method. Even in the case of partial coelution of some divalent metal complexes, the identification is possible by their distinct mass spectra. The stability of metal complexes during separation was checked by injecting ethylenediaminetetraacetic acid (EDTA) after each run of metal-phytosiderophore complexes. Good stability of divalent-phytosiderophores, except for Fe(II)-complexes, was observed. During gradient separation, Fe(III)-complexes are partly dissociated (<20%), but a good sensitivity of Fe(III)-DMA in real plant samples is still achieved. In order to avoid instability problems with the separation of Fe-complexes, an isocratic separation is proposed, which allows the separation of ferrous and ferric complexes in 2 min.

Chromatography, Liquid↗

Validation of a diffusive sampling method for airborne low-molecular isocyanates using 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole-impregnated filters and liquid chromatography-tandem mass spectrometry.

A diffusive sampling method for the determination of low-molecular isocyanates as their 4-nitro-7-piperazinobenzo-2-oxa-1,3-diazole (NBDPZ) derivatives using tandem mass spectrometry (MS/MS) after atmospheric pressure chemical ionisation (APCI) is presented. Isocyanic acid (ICA), methyl isocyanate (MIC), ethyl isocyanate (EIC) and phenyl isocyanate (PhIC) are collected on NBDPZ-impregnated polystyrene divinyl benzene (SDB) filter tapes. The method was validated for MIC, EIC and PhIC for concentrations between 0.5 and 50 ppb at relative humidity (RH) conditions from 10 up to 90%. Validation was carried out by active sampling using 1-(2-methoxyphenyl)piperazine (2-MP) as derivatising agent. Sampling periods applied were between 15 min and more than 8 h. The sampling rates were determined to be 21.0 mL/min for MIC with a relative standard deviation (RSD) of 9.0% for 184 samplers, 15.6 mL/min for EIC (RSD 11.6%; N = 154) and 11.5 mL/min for PhIC (RSD 8.4%; N = 87). The limits of quantification were 1.4 ppb for MIC and 1.3 ppb for EIC and PhIC applying 15 min sampling periods. Owing to high background signals, isocyanic acid could only be determined when it was present in concentrations in the high ppb range.

Air↗

Different iron-chelating properties of pyochelin diastereoisomers revealed by LC/MS.

Pyochelin is a siderophore and virulence factor common to Burkholderia cepacia and several Pseudomonas strains. It is isolated from bacterial media as a mixture of two epimers, which readily equilibrate in most solvents. Experiments based on high-performance liquid chromatography/electrospray ionization mass spectrometry are reported here, allowing the investigation of the different Fe(III)-chelating properties of pyochelin diastereomers in solution without the need for labourious isolation. It is demonstrated in this study that only one of the two pyochelin diastereomers is able to chelate Fe(III); no Fe(III) complexes of the other diastereomer could be detected. The Fe(III)-pyochelin complex exhibited a 1:1 metal-to-siderophore ratio and no evidence for other stoichiometries was found.

Chromatography, Liquid↗

Analysis of iron(II)/iron(III) phytosiderophore complexes by nano-electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

Nano-electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (nano-ESI-FTICRMS) was employed for the analysis of the phytosiderophore 2'-deoxymugineic acid (DMA) and the candidate ligand for the intracellular iron transport in plants nicotianamine (NA). Due to the zwitterionic nature of NA and DMA, complementary mass spectra were obtained in positive and negative ionization modes. The technique was also used for speciation of their complexes with Fe(II) and Fe(III), respectively. The species observed at pH 7.3 are the 1:1 Fe-ligand complexes and no evidence for the existence of dimeric complexes was observed. NA and DMA differ only by one mass unit. Consequently, in the system NA + DMA + Fe(II)/Fe(III), there are pairs of iron species (i.e. NA-Fe(II) and DMA-Fe(III)) with the same nominal mass, which differ only by approximately 0.02 mass units. It is shown that high-resolution MS accompanied by accurate mass data analysis allows the unequivocal identification of all four iron species (NA-Fe(II), NA-Fe(III), DMA-Fe(II), DMA-Fe(III)) in one solution without separation. We also addressed the possible alteration of the oxidation state of chelated iron under nano-ESI conditions, but no redox reactions were observed under optimized conditions.

Journal Article↗

Rapid identification of siderophores by combined thin-layer chromatography/matrix-assisted laser desorption/ionization mass spectrometry.

The investigation of a combined thin-layer chromatography/matrix-assisted laser desorption/ionization mass spectrometry (TLC/MALDI-MS) method for the analysis of siderophores from microbial samples is described. The investigated siderophores were enterobactin, ferrioxamine B, ferrichrome, ferrirhodin, rhodotorulic acid and coprogen. Solid-phase extraction was employed to recover the siderophores from the microbial samples. After visualization of the spots via spraying with ferric chloride or chrome azurol sulfonate assay solution, the MALDI matrix was applied to the gel surface. Several TLC/MALDI experimental parameters were optimized, such as type and concentration of MALDI matrix, as well as the type and composition of solvent to facilitate analyte transport from the inside of the TLC gel to the surface. The impact of these parameters on sensitivity, precision and ion formation of the various siderophores was studied. The detection limits for the investigated siderophores were in the range 1-4 pmol. These values were about 4-24 times higher than the detection limits obtained directly from stainless steel MALDI targets. The differences were most likely due to incomplete transport of the 'trapped' analyte molecules from the deeper layers of the TLC gel to the surface and into the matrix layer. In addition, chromatographic band broadening spread the analyte further in TLC as compared with the steel plates, resulting in less analyte per surface area. The identification of the siderophores was aided by concurrently applying a Ga(III) nitrate solution to the TLC plate during the visualization step. The resulting formation of Ga(III) complexes lead to distinctive (69)Ga/(71)Ga isotope patterns in the mass spectra. The versatility of the TLC/MALDI-MS assay was demonstrated by using it to analyze siderophores in a Pseudomonas aeruginosa sample. An iron-binding compound was identified in the sample, namely pyochelin (2-(2-o-hydroxyphenyl-2-thiazolin-4-yl)-3-methylthiazolidine-4-carboxylic acid).

Chromatography, High Pressure Liquid↗

Liquid chromatographic-mass spectrometric studies on the in vitro degradation of a poly(ether ester) block copolymer.

A detailed study on the in vitro degradation of a poly(ethylene glycol) and poly(butylene terephthalate) (PEOT/PBT) segmented block copolymer was carried out using liquid chromatography/electrospray-mass spectrometry. Accelerated hydrolysis of PEOT/PBT was achieved by placing the material for 14 days in a refluxing phosphate buffered saline (pH 7.4) solution. All major degradation products and several side-products were identified using both the positive and the negative ion mode. The data indicate that degradation does not only occur in the "soft", but also in the "hard" segments of the polymer. Liquid chromatographic separation is required to distinguish between degradation products with different sequences but identical molecular mass. The addition of ammonium and sodium ions provided important complementary information on the number of monomer units present in the degradation products.

Chromatography, Liquid↗

Liquid chromatography/coordination ion spray-mass spectrometry for the analysis of rubber vulcanization products.

Liquid chromatography/coordination ion spray-mass spectrometry has been used for the identification of reaction products in a model rubber vulcanization process. After LC separation using reversed-phase conditions, AgBF(4) in acetonitrile was added, and strong signals were observed for silica-rubber coupling agents and products of the reaction between these and alkenes. The method performs best for substances containing sulfur chains with chain lengths between two and eight sulfur atoms, but sulfur-free compounds containing triethoxysilyl groups were detected as well. For the latter, the postcolumn addition of NaBF(4) proved to be a suitable alternative. Besides the coupling agents, various reaction products, including sulfur-chain bridged alkenes were identified.

Journal Article↗

Analysis of phenothiazine and its derivatives using LC/electrochemistry/MS and LC/electrochemistry/fluorescence.

The on-line electrochemical conversion of phenothiazine and its derivatives after liquid chromatographic separation has been studied by mass spectrometry and fluorescence spectroscopy. In an electrochemical cell consisting of porous glassy carbon, the phenothiazines are readily converted to oxidized products, which can be detected by on-line fluorescence spectroscopy and mass spectrometry. The method allows rapid investigations on the electrochemical oxidation pathways, as demonstrated for phenothiazine itself. The phenothiazine derivatives are transferred into their strongly fluorescent sulfoxides. Based on this reaction, an LC/electrochemistry/fluorescence method was developed that allows for limits of detection between 5 x 10(-9) and 4 x 10(-8) mol/L and limits of quantification between 2 x 10(-8) and 1 x 10(-7) mol/L for the individual phenothiazines. The linear ranges comprised three decades starting at the limit of quantification.

Chromatography, Liquid↗

Liquid chromatography-electrochemistry-mass spectrometry of polycyclic aromatic hydrocarbons.

An efficient method for fast elucidation of the electrochemical reactions of polycyclic aromatic hydrocarbons (PAH) has been set up by applying post-column electrochemistry in liquid chromatography-mass spectrometry (LC-MS). With this set-up strong improvement of sensitivity in the LC-MS analysis of PAH is observed. Due to their low redox potentials, the non-polar PAH are converted into the respective radical cations, which may further react with constituents of the mobile phase and in additional electrochemical oxidation steps. Among other products, mono-, di-, and trioxygenated species are observed in aqueous solutions, alkoxylated compounds in alcohols, and solvent adducts in the presence of acetonitrile. While more different products are observed by using atmospheric pressure chemical ionization in the positive-ion mode (APCI(+)), the deprotonation of hydroxylated species results in very clear spectra in the negative-ion mode (APCI(-)). Deuterated PAH and deuterated solvents were used to gain additional information on the formation of the reaction products.

Journal Article↗

Strategies for the liquid chromatographic-mass spectrometric analysis of non-polar compounds.

Electrospray ionization and atmospheric pressure chemical ionization (APCI) have evolved recently as very useful tools for the liquid chromatographic-mass spectrometric (LC-MS) analysis of polar substances. Non-polar compounds, however, are difficult to analyze with these atmospheric pressure ionization techniques due to their soft ionization mechanism. Recently, new approaches have been introduced which are likely to overcome this obstacle, at least partly. On-line electrochemical conversion of the analytes to more polar reaction products, atmospheric pressure photoionization, atmospheric pressure electron capture negativeion-MS and coordination ionspray-MS are four techniques which are presented in detail compared and discussed critically with respect to their current status and future perspectives. Particular focus is directed from a chemical viewpoint on the substance groups which are accessible by each of the new approaches.

Atmospheric Pressure↗

Liquid chromatography with on-line electrochemical derivatization and fluorescence detection for the determination of phenols.

A new methodological approach for the determination of monosubstituted phenols is described. After liquid chromatographic separation of the analytes, an on-line electrochemical derivatization is carried out and the reaction products are detected fluorometrically. Phenols are oxidized in the electrochemical cell to form fluorescent dimers and higher oligomers, which were identified by on-line electrochemistry/mass spectrometry. Major advantages of the proposed method include enhanced selectivity and sensitivity. Without prior enrichment of the analytes, limits of detection down to 2 x 10(-9) M (20 fmol) may be reached for selected phenols, e.g., for 4-octylphenol, 4-ethylphenol, and 4-(1-indanyl)phenol. Only readily available instrumentation is required for these measurements.

Journal Article↗

LC-electron capture-APCI(-)-MS determination of nitrobenzoxadiazole derivatives.

Nitrobenzoxadiazole (NBD) derivatives are determined with limits of detection ranging down to 20 nmol l(-1) using liquid chromatography-mass spectrometry (LC-MS) with electron capture (EC) ionisation. An atmospheric pressure chemical ionisation (APCI) interface operated in the negative ion mode is used as ionisation source. Amine derivatives of 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBDCl) as well as the isocyanate derivatives of 4-nitro-7-piperazino-2,1,3-nitrobenzoxadiazole (NBDPZ) have been analysed using this technique. The parameters favouring electron capture mechanisms have been investigated thoroughly under consideration of the competing mechanism of deprotonation to allow a better understanding of the electron capture process and to improve selectivity of the analysis.

Chromatography, Liquid↗

LC-electron capture APCI-MS for the determination of nitroaromatic compounds.

The determination of selected nitroaromatic compounds in liquid chromatography-mass spectrometry with electron capture (EC) ionisation using a commercial atmospheric pressure chemical ionisation (APCI) interface in the negative mode is described. The electron capture effect is observed for nitroaromatics which do not easily undergo deprotonation under these conditions. Depending on the structure of the analytes, either dissociative or, for the first time in LC-MS, non-dissociative electron capture is observed. Limits of detection and linear range for the determination of the analytes match those obtained for nitroaromatics which undergo deprotonation. The investigated substances comprise numerous substituted nitrobenzenes and nitrobenzooxadiazoles.

Journal Article↗