A pseudodifferential amplifier for bioelectric events with DC-offset compensation using two-wired amplifying electrodes.

Most wired active electrodes reported so far have a gain of one and require at least three wires. This leads to stiff cables, large connectors and additional noise for the amplifier. The theoretical advantages of amplifying the signal on the electrodes right from the source has often been described, however, rarely implemented. This is because a difference in the gain of the electrodes due to component tolerances strongly limits the achievable common mode rejection ratio (CMRR). In this paper, we introduce an amplifier for bioelectric events where the major part of the amplification (40 dB) is achieved on the electrodes to minimize pick-up noise. The electrodes require only two wires of which one can be used for shielding, thus enabling smaller connecters and smoother cables. Saturation of the electrodes is prevented by a dc-offset cancelation scheme with an active range of +/- 250 mV. This error feedback simultaneously allows to measure the low frequency components down to dc. This enables the measurement of slow varying signals, e.g., the change of alertness or the depolarization before an epileptic seizure normally not visible in a standard electroencephalogram (EEG). The amplifier stage provides the necessary supply current for the electrodes and generates the error signal for the feedback loop. The amplifier generates a pseudodifferential signal where the amplified bioelectric event is present on one lead, but the common mode signal is present on both leads. Based on the pseudodifferential signal we were able to develop a new method to compensate for a difference in the gain of the active electrodes which is purely software based. The amplifier system is then characterized and the input referred noise as well as the CMRR are measured. For the prototype circuit the CMRR evaluated to 78 dB (without the driven-right-leg circuit). The applicability of the system is further demonstrated by the recording of an ECG.

Amplifiers, Electronic↗

Enhancing interference rejection of preamplified electrodes by automated gain adaption.

The use of preamplified electrodes in electrocardiography (ECG) or electroencephalography (EEG) has a numbe of benefits, most importantly, the noise reduction through preamplification and the interference reduction through buffering (Fernandez and Pallas-Areny, 1997). Normally, preamplified electrodes are not used because the mismatch in amplification due to component tolerances leads to a reduced common mode rejection ration (CMRR) (Pallas-Areny and Webster, 1991). In this paper, we introduce a new technique to restore the CMRR. We do this by adapting the gain of the differential amplifier (DA) following the preamplified electrodes. The technique is based on measuring the transfer function of a chosen common mode signal. The gain of the DA is adjusted by a closed loop controller to maximize the CMRR. With this technique, there is no adverse effect on the ECG or EEG. In this way, the control loop can be operated continuously if needed.

Algorithms↗