PubMed Health⌕ Search

Biomedical subjects

Helen Owens

Publications and source records attributed to Helen Owens.

8 recordsLinked to original sources

The Nepal Longitudinal Study: biometric characteristics of developing eyes.

PURPOSE: To identify differences in potential biometric markers for predicting refractive error in school children. METHODS: Biometric data on 895 Tibetan children, aged 6 to 18 years, residing in Katmandu, Nepal, were collected biennially from 1992 to 2000. Measurements included cycloplegic autorefraction, A-scan ultrasonography, and video phakometry. Only those children who had been studied at least once at age 12 years or more were included in the analysis. Subjects were divided into two groups: a myopia group if the refractive error was myopic by more than -0.50 D and a nonmyopia group if the refractive error was maximally myopic by -0.50 D, expressed as a spherical equivalent error in the left eye. RESULTS: Biometric measures that differed significantly with increasing age between the two refractive groups included: anterior chamber depth + 0.012 mm/year (p = 0.014), anterior lens radius of curvature + 0.073 mm/year (p = 0.001), lens power -0.059 D/year (p = 0.082), lens thickness -0.005 mm/year (p = 0.02), and vitreous chamber depth + 0.084 mm/year (p < 0.001). Corneal radii of curvature of the myopic group were steeper at all ages by 0.09 mm (p < 0.001), but the rate of change with age was equivalent across the refractive groups. CONCLUSIONS: Compared with those who remained nonmyopic, children who developed myopia had a crystalline lens that was initially thicker and steeper, and a vitreous chamber that was initially shorter. With age, children who became myopic developed greater lens thinning, greater flattening of the anterior lens surface radius, and a greater increase in vitreous chamber depth than their nonmyopic counterparts.

Adolescent↗

Posterior corneal changes with orthokeratology.

PURPOSE: To investigate changes in corneal thickness and the radius of curvature of the posterior corneal surface after orthokeratology (OK) rigid lens wear. METHODS: Nineteen young myopic subjects wore reverse-geometry OK lenses (BE/ABE, Ultravision Contact Lenses, Brisbane, Australia) every night for 1 month. Central and midperipheral corneal thickness (Allergan Humphrey ultrasound, Carl Zeiss Meditec, Dublin, CA), topography (EyeSys v.3.1, Houston, TX), subjective refraction, and posterior corneal radii (video photography of Purkinje images) were evaluated within 2 h of waking, prelens wear, and on four occasions postlens wear during a 1-month period. A mixed-models approach was used to analyze the data. We modeled the changes in posterior corneal radius of curvature and corneal thickness in terms of the sagittal height of the anterior and posterior cornea using an ellipsoidal model for the corneal surfaces. RESULTS: Refractive error reduced from -2.28 to -0.01 DS within 1 month. A significant thinning of the cornea was evident between 1 (p = 0.03) and 2 weeks (p = 0.0048) postlens wear. A significant increase in the anterior corneal radius of curvature was present at all time periods beyond 1 night (p < 0.001), and a significant posterior corneal flattening occurred centrally and midperipherally after 1 week (p = 0.04 and p = 0.013, respectively). CONCLUSIONS: These findings suggest that in addition to the significant topographic flattening of the anterior corneal surfaces, there is also a significant flattening of the posterior surface during the early adaptive stages of OK lens wear.

Adolescent↗

The relationship between the sagitta of the anterior corneal surface and refractive error of the eye.

Changes in the sagitta of the anterior corneal surface associated with a change in the corneal radius of curvature have been used to calculate the change in refractive error of the eye in two areas: the ablation depth for laser surgery, and the change in corneal thickness associated with orthokeratology lens wear. An approximate formula known as Munnerlyn's formula is commonly used to calculate the refractive error change from sagittal data. This article compares the change in refraction calculated using the approximate formulae with the change calculated from a formula based on an elliptical corneal section. The approximate formula underestimates the ablation depth for a given refractive change and overestimates the refractive change for a given change in corneal thickness, assuming a constant asphericity. When the corneal asphericity increases together with an increase in radius of curvature, a suggested mechanism in orthokeratology, the approximate formula underestimates the change in ocular refraction.

Cornea↗

A profile of keratoconus in New Zealand.

PURPOSE: To examine the characteristics and risk factors for keratoconus in a New Zealand population. METHODS: A one-page questionnaire was designed and sent to optometrists and ophthalmologists in New Zealand. Eye care practitioners then issued questionnaires to their keratoconic patients over a 6-month period. RESULTS: A total of 673 completed questionnaires were received from patients with keratoconus. A male bias (59%) was apparent in the sample. In line with previous work, a high proportion of the keratoconic cohort rubbed their eyes and suffered from atopy. A familial rate of 23.5% was evident, with several families reporting multiple keratoconus cases. Eleven pairs of twins were identified with at least one keratoconic sibling. Multivariate statistical analysis revealed significant independent correlations between the early development of keratoconus and gender, allergy, asthma, and latitude of childhood domicile. CONCLUSION: Results from the survey concur with a previous local report that keratoconus affects males more frequently and earlier in life than females in New Zealand. The concurrence of atopic disease and eye rubbing with keratoconus was as expected, and an association between the early development of the disease and latitude of the childhood domicile emerged. A strong familial component, exceeding previously reported figures, was evident in the cohort.

Adult↗

Accuracy of Orbscan II slit-scanning elevation topography.

PURPOSE: To establish the accuracy of Orbscan II (Orbtek Inc.) slit-scanning elevation topography in analyzing the anterior surface of complex test objects. SETTING: Discipline of Ophthalmology, University of Auckland, Faculty of Medical and Health Sciences, Auckland, New Zealand. METHODS: Six test objects were created from 2 materials: standard calibration poly(methyl methacrylate) (PMMA) (Orbtek Inc.) and a research PMMA material. The test objects were produced with spherical (radii of curvature 6.00 mm, 7.67 mm, and 8.88 mm), aspherical (apical radius 7.67, eccentricity 0.5, Q -0.25), and toroidal (7.67/7.92 mm radii of curvature) surfaces. The accuracy of the test surfaces was established by Form Talysurf Analysis. A single calibrated Orbscan II device was used to obtain 20 separate anterior elevation maps of each test object. The data obtained from Orbscan II, at 0.2 mm intervals along the chosen meridian, were directly compared with the Talysurf values for each test surface. RESULTS: Orbscan II measurements of all test objects were statistically significantly different from the Talysurf values (P <.001). The test objects produced from standard calibration material were more accurately measured by Orbscan II than the objects produced from the research material. Data obtained by Orbscan II from the central 3.5 mm of all test objects were more accurate than peripheral data when compared with the Talysurf values (P =.001). CONCLUSIONS: Orbscan II anterior surface elevation measurements differed significantly from Form Talysurf Analysis of complex test surfaces. However, the magnitude of the errors in the measurement of standard test objects was small, less than 0.20 microm centrally and 0.70 microm peripherally. Clinically, if similar accuracy of measurement is confirmed in the human eye, anterior surface elevation maps can be considered accurate representations of corneal shape.

Contact Lenses↗

Effect of softperm lens wear on corneal thickness and topography: a comparison between keratoconic and normal corneae.

PURPOSE: Complications related to contact lens-induced anoxia in the keratoconic eye are well documented, but the underlying mechanisms are poorly understood. This study compared topographical changes in corneal thickness and anterior corneal radius following SoftPerm (Ciba Vision, Atlanta, GA) (rigid-and-soft combination) lens wear in a group of keratoconic and normal individuals. METHODS: Video keratoscopic (VKS) (EyeSys, Houston, TX) and ultrasonographic pachometry measurements were taken at nine ocular locations, at central, mid-peripheral, and peripheral corneal areas of keratoconic and normal subjects. Subjects were subsequently fitted with SoftPerm lenses and further measurements of corneal topography and thickness were noted after 1 day, 2 weeks, and 1 month of daily wear. RESULTS: Corneal thickness increased significantly in normal and keratoconic eyes following SoftPerm lens wear. Radius values obtained from the VKS measurements indicated that a significant and progressive degree of corneal flattening occurred for the keratoconic subjects at the 1-day, 2-week, and 1-month intervals, in contrast to the normal group, whose corneal radii remained unchanged. CONCLUSIONS: Corneal swelling occurs in both normal and keratoconic corneas following SoftPerm lens wear. Differences in the apparent central edema response within the keratoconic group may relate to the ease with which these corneas may be molded by a rigid contact lens.

Adult↗

Age dependence of ocular biometric measurements under cycloplegia with tropicamide and cyclopentolate.

BACKGROUND: Cyclopentolate continues to be the cycloplegic of choice for refracting young children, although many studies of ocular biometry promote the use of tropicamide. METHODS: To clarify the role of drug type in biometric measurements, cycloplegia was induced in two disparate age groups using cyclopentolate and tropicamide on two separate occasions. Refraction, phakometry and A-scan ultrasonography measurements were made on two groups of Tibetan children resident in Nepal. RESULTS: Cyclopentolate produced significantly more cycloplegia in the younger group, which was supported by phakometry measurements. However, in clinical terms, the difference between the measurements was not significant. CONCLUSION: We conclude that although cyclopentolate is more effective than tropicamide in relaxing accommodation in young children, the use of a local anaesthetic prior to instillation of tropicamide produces refractive data virtually equivalent to that of cyclopentolate, regardless of the age group measured. However, biometric measurements may be susceptible to greater error when near fixation targets are used during phakometry procedures.

Journal Article↗