PubMed Health⌕ Search

Biomedical subjects

Helen Segal

Publications and source records attributed to Helen Segal.

4 recordsLinked to original sources

Screening for aspirin responsiveness after transient ischemic attack and stroke: comparison of 2 point-of-care platelet function tests with optical aggregometry.

BACKGROUND AND PURPOSE: Recent studies suggest that patients who do not respond to aspirin (ASA) therapy may be at increased risk of ischemic vascular events. The availability of simple to use point-of-care (POC) platelet function tests now potentially allows aspirin nonresponsiveness to be identified in routine clinical practice. However, there are very few data on whether the different tests produce consistent results. We therefore compared 2 POC tests (PFA-100 device and the Ultegra-RPFA [RPFA]) with conventional light transmission aggregometry (LTA). METHODS: Platelet function was assessed by all 3 tests in 100 patients receiving low-dose ASA therapy after transient ischemic attack (TIA) or ischemic stroke. RESULTS: The incidence of ASA nonresponsiveness was 17% by the RPFA and 22% by the PFA-100, compared with only 5% by LTA (ie, as defined with both arachidonic acid and ADP). Agreement between the RPFA and the PFA-100 and arachidonic acid induced LTA was poor (kappa=0.16, 95% CI, -0.08 to 0.39, P=0.11; and kappa=0.09 -0.12 to 0.30, P=0.32, respectively). Agreement between the 2 POC tests was also poor (kappa=0.14, -0.08 to 0.36, P=0.15). Only 2% of patients were aspirin nonresponders by all 3 tests. CONCLUSIONS: The prevalence of apparent ASA nonresponsiveness was higher with both the POC tests than with LTA. However, agreement between the tests was poor and very few patients were ASA nonresponsive by all 3 tests. Aspirin nonresponsiveness is therefore highly test-specific and large prospective studies will be required to determine the prognostic value of each of the separate tests.

Adult↗

High incidence of defective high-shear platelet function among platelet donors.

BACKGROUND: Because single-donor plateletpheresis concentrates now account for a large percentage of PLT concentrates, the PLT quality of individual donations is increasingly important. There has been little previous work on PLT function in blood donors. STUDY DESIGN AND METHODS: The aim of this study was to investigate the prevalence of defective PLT function among 100 healthy UK PLT donors on 3 consecutive donation days. Citrated blood samples were taken before plateletpheresis. High-shear PLT function testing was performed by a PLT function analyzer (PFA-100, Dade Behring), within both collagen-ADP (CADP) and collagen-epinephrine (CEPI) cartridges. RESULTS: Sixteen percent of PLT donors (mainly over the 3 donating days) had prolonged CEPI closure times (CTs) only, indicative of an aspirin-like pattern; 9 percent had a severe defect with prolonged CEPI CTs between 200 and 300 seconds, and 4 percent had maximal CEPI CTs of greater than 300 seconds. The majority of prolonged CEPI CTs appeared transient in nature. CONCLUSION: PLT dysfunction as detected by the PFA-100 is surprisingly common within a voluntary PLT donor population. The majority of CEPI defects appeared transient in nature and are indicative of surreptitious intake of cyclooxygenase inhibitors (e.g., aspirin). Identification of defective PLT function within donors would provide a simple means to eradicate defective PLTs from being clinically utilized.

Adult↗