Esophageal acid exposure in upright and recumbent postures: roles of lower esophageal sphincter, esophageal contractile and transport function, hiatal hernia, age, sex, and body mass.

This study aimed to assess, using multiple regression analyses, the roles of lower esophageal sphincter, esophageal contractile and transport function, hiatal hernia, age, sex, and body mass for esophageal acid exposure in upright and recumbent postures and for esophagitis. In 116 patients with reflux symptoms, acid exposure was recorded by 24-hr pH monitoring, motility manometrically, bolus transport scintigraphically, hiatal hernia and esophagitis endoscopically. In upright posture, the percentage time at pH <4 increased significantly with higher body mass index and lower distal esophageal amplitude, the number of episodes >5 min at pH <4 with lower distal amplitude, slower transport, and higher body mass, and the longest episode at pH <4 with lower distal amplitude. In recumbency, the percentage time at pH <4 increased with lower percentage of effective esophageal contraction waves and male sex, and the number of episodes and the longest episode with lower percentage effective waves. The severity of esophagitis augmented with slower supine transport and male sex. In both postures, acid exposure and esophagitis seem to be determined primarily by impaired esophageal motility and the ensuing slow bolus transport rather than by compromised lower esophageal sphincter function and the presence and size of a hiatal hernia.

Adult↗

[Evaluation of the performance of a gamma camera equipped with a 5/8" versus 1" thick NaI detector].

The upgrade of a gamma camera from a 5/8" to a 1" thick crystal, the latter with StarBrite technology, prompted to the investigation of changes in performance parameters for planar scintigraphy and SPECT as well as for PET in coincidence mode. For planar and SPECT parameters, the performance was measured according to NEMA Standard Protocol NU1-2001. No changes were found in terms of intrinsic uniformity, intrinsic spatial resolution, linearity, energy resolution, system resolution, and tomographic system resolution. The only change was an increase of system sensitivity for higher energy gamma rays. For the PET scanner in coincidence mode, the image quality of the camera was determined according to NEMA NU2-2001. Visually and in terms of contrast values there was a significant improvement of image quality. Changes in image quality relevant for clinical use were tested by evaluation of planar patient scans acquired within a short time with two gamma cameras of the same type, different only in crystal thickness (5/8" and 1"). No statistically significant difference was found between corresponding scans. For planar and SPECT imaging, the gamma camera with 1" thick detector and StarBrite technology demonstrated the same performance of a camera with a 5/8" crystal. For PET in coincidence mode the new detector proved clearly superior.

Equipment Design↗

An inter-laboratory comparison study of image quality of PET scanners using the NEMA NU 2-2001 procedure for assessment of image quality.

An inter-laboratory comparison study was conducted to assess the image quality of PET scanners in Austria. The survey included both dedicated PET scanners (D-PET, n = 8) and coincidence cameras (GC-PET, n = 7). Measurement of image quality was based on the NEMA (National Electrical Manufacturers Association) NU 2-2001 protocol and the IEC (International Electrotechnical Commission) body phantom. The latter contains six fillable spheres ranging in diameter from 37 mm down to 10 mm and a 'lung' insert. The two largest lesions L1-2 simulate cold lesions, the four smaller ones (L3-6) are filled with 18F and activity concentration ratios relative to background of 8:1 and 4:1, respectively. Acquisition and reconstruction in the study employed the participating institutes' standard oncological processing protocol. Calculation of contrast of the spheres was performed with a fully automated procedure. Contrast quality indices (CQIs) reflecting global performance were obtained by summing individual contrast values. Other image quality parameters calculated according to the NEMA protocol were background variability and relative error for correction of attenuation and scatter. Contrast values obtained were 61 +/- 16 and 37 +/- 14 for L1 (per cent contrast +/- SD for D-PET and GC-PET, respectively), 57 +/- 16 and 29 +/- 16 for L2, 46 +/- 10 and 26 +/- 6.3 for L3, 37 +/- 10 and 15 +/- 4.3 for L4, 26 +/- 11.5 and 6.1 +/- 2.5 for L5, 14 +/- 7.1 and 2.6 +/- 2.6 for L6, with D-PET systems consistently being superior to GC-PET systems. CQIs permitted ranking of the scanners, also demonstrating a clear distinction between D-PET and GC-PET systems. Background variability was largest for GC-PET systems; the relative error of attenuation and scatter correction was significantly correlated with image quality for D-PET systems only. The study demonstrated considerable differences in image quality not only between GC-PET and D-PET systems but also between individual D-PET systems with possible consequences for clinical interpretation of images and measurement of quantitative indices such as the standardized uptake value. The study provided valuable feedback to the participants as well as baseline data for improving interchangeability of PET images and of quantitative indices between different laboratories.

Austria↗

Stability of miniature electromagnetic tracking systems.

This study aims at a comparative evaluation of two recently introduced electromagnetic tracking systems under reproducible simulated operating-room (OR) conditions: the recently launched Medtronic StealthStation, Treon-EM and the NDI Aurora. We investigate if and to what extent these systems provide improved performance and stability in the presence of surgical instruments as possible sources of distortions compared with earlier reports on electromagnetic tracking technology. To investigate possible distortions under pseudo-realistic OR conditions, a large Langenbeck hook, a dental drill with its handle and an ultrasonic (US) scanhead are fixed on a special measurement rack at variable distances from the navigation sensor. The position measurements made by the Treon-EM were least affected by the presence of the instruments. The lengths of the mean deviation vectors were 0.21 mm for the Langenbeck hook, 0.23 mm for the drill with handle and 0.56 mm for the US scanhead. The Aurora was influenced by the three sources of distortion to a higher degree. A mean deviation vector of 1.44 mm length was observed in the vicinity of the Langenbeck hook, 0.53 mm length with the drill and 2.37 mm due to the US scanhead. The maximum of the root mean squared error (RMSE) for all coordinates in the presence of the Langenbeck hook was 0.3 mm for the Treon and 2.1 mm for the Aurora; the drill caused a maximum RMSE of 0.2 mm with the Treon and 1.2 mm with the Aurora. In the presence of the US scanhead, the maximum RMSE was 1.4 mm for the Treon and 5.1 mm for the Aurora. The new generation of electromagnetic tracking systems has significantly improved compared to common systems that were available in the middle of the 1990s and has reached a high level of technical development. We conclude that, in general, both systems are suitable for routine clinical application.

Artifacts↗

Wobbled splatting--a fast perspective volume rendering method for simulation of x-ray images from CT.

3D/2D registration, the automatic assignment of a global rigid-body transformation matching the coordinate systems of patient and preoperative volume scan using projection images, is an important topic in image-guided therapy and radiation oncology. A crucial part of most 3D/2D registration algorithms is the fast computation of digitally rendered radiographs (DRRs) to be compared iteratively to radiographs or portal images. Since registration is an iterative process, fast generation of DRRs-which are perspective summed voxel renderings-is desired. In this note, we present a simple and rapid method for generation of DRRs based on splat rendering. As opposed to conventional splatting, antialiasing of the resulting images is not achieved by means of computing a discrete point spread function (a so-called footprint), but by stochastic distortion of either the voxel positions in the volume scan or by the simulation of a focal spot of the x-ray tube with non-zero diameter. Our method generates slightly blurred DRRs suitable for registration purposes at framerates of approximately 10 Hz when rendering volume images with a size of 30 MB.

Algorithms↗

Variations in the output power and surface heating effects of transducers in therapeutic ultrasound.

OBJECTIVE: To determine the real emitted output power and maximum surface heating of commercial therapeutic ultrasound transducers emitting in air for various therapeutic regimens. DESIGN: Surface temperatures of ultrasound transducers with frequencies of .05 to 3 MHz were detected over 5 minutes by using a calibrated infrared thermographic camera; additionally, the indicated output power was checked with a radiation force balance. SETTING: University center for biomedical engineering and physics and medical school for physical medicine and rehabilitation. PARTICIPANTS: Not applicable. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Power variations and surface temperatures of clinical devices were analyzed to determine whether they comply with obligatory limits given in International Electrotechnical Commission standard 60601-2-5. RESULTS: Depending on the operation mode and the output power, surface temperatures ranged between 24.2 degrees to 80 degrees C within 5 minutes. Differences between measured and displayed power output (limit, +/-20%) ranged between -32% and 28%. CONCLUSIONS: The effectiveness of treatment is lowered if the value of emitted power is not known reliably. In the worst case, damage or irritation of the skin is possible, particularly in patients with sensory compromised skin. Damage may be caused by hot surfaces if the threshold level required to activate the device is lowered or if the device is defective. Improved thermal control units are necessary to prevent potential thermal hazards. Regular checks of transducer emission should be obligatory to ensure correct and precise function of the clinical devices.

Temperature↗

Robot-assisted biopsy using computed tomography-guidance: initial results from in vitro tests.

PURPOSE: We sought to develop a robotic system for computed tomography (CT)-guided biopsy to validate the feasibility, accuracy, and efficacy of the system using phantom tests. MATERIALS AND METHODS: Ten peas (mean diameter 9.9+/-0.4 mm) embedded within a gel phantom were selected for biopsy. Once the best access was defined on CT images, the position of the phantom was recorded by an optical tracking system. Positional data about the phantom and the corresponding CT image was transferred to the robot planning system (Linux-based industrial PC equipped with video capture card). Once the appropriate position, angulation, and pitch were calculated, the robotic arm moved automatically with 7 degrees-of-freedom to the planned insertion path, aiming the needle-trajectory at the center of the target. Then, the biopsy was performed manually using a coaxial technique. The length of all harvested specimens was measured and short cut pieces of a guidewire were pushed into the target to evaluate the deviation of the actual needle track from the target. RESULTS: In all targets, biopsy specimens (mean length 5.6+/-1.4 mm) were harvested with only 1 needle pass required. The mean deviation of the needle tip from the center of the target in the x and z axes was 1.2+/-0.9 mm and 0.6+/-0.4 mm, respectively. CONCLUSIONS: Robotic-assisted biopsies in vitro, using CT guidance, were feasible and provided high accuracy.

Biopsy↗

A fully automated calibration method for an optical see-through head-mounted operating microscope with variable zoom and focus.

Ever since the development of the first applications in image-guided therapy (IGT), the use of head-mounted displays (HMDs) was considered an important extension of existing IGT technologies. Several approaches to utilizing HMDs and modified medical devices for augmented reality (AR) visualization were implemented. These approaches include video-see through systems, semitransparent mirrors, modified endoscopes, and modified operating microscopes. Common to all these devices is the fact that a precise calibration between the display and three-dimensional coordinates in the patient's frame of reference is compulsory. In optical see-through devices based on complex optical systems such as operating microscopes or operating binoculars-as in the case of the system presented in this paper-this procedure can become increasingly difficult since precise camera calibration for every focus and zoom position is required. We present a method for fully automatic calibration of the operating binocular Varioscope M5 AR for the full range of zoom and focus settings available. Our method uses a special calibration pattern, a linear guide driven by a stepping motor, and special calibration software. The overlay error in the calibration plane was found to be 0.14-0.91 mm, which is less than 1% of the field of view. Using the motorized calibration rig as presented in the paper, we were also able to assess the dynamic latency when viewing augmentation graphics on a mobile target; spatial displacement due to latency was found to be in the range of 1.1-2.8 mm maximum, the disparity between the true object and its computed overlay represented latency of 0.1 s. We conclude that the automatic calibration method presented in this paper is sufficient in terms of accuracy and time requirements for standard uses of optical see-through systems in a clinical environment.

Algorithms↗

Design and application of an assessment protocol for electromagnetic tracking systems.

This paper defines a simple protocol for competitive and quantified evaluation of electromagnetic tracking systems such as the NDI Aurora (A) and Ascension microBIRD with dipole transmitter (B). It establishes new methods and a new phantom design which assesses the reproducibility and allows comparability with different tracking systems in a consistent environment. A machined base plate was designed and manufactured in which a 50 mm grid of holes was precisely drilled for position measurements. In the center a circle of 32 equispaced holes enables the accurate measurement of rotation. The sensors can be clamped in a small mount which fits into pairs of grid holes on the base plate. Relative positional/orientational errors are found by subtracting the known distances/ rotations between the machined locations from the differences of the mean observed positions/ rotation. To measure the influence of metallic objects we inserted rods made of steel (SST 303, SST 416), aluminum, and bronze into the sensitive volume between sensor and emitter. We calculated the fiducial registration error and fiducial location error with a standard stylus calibration for both tracking systems and assessed two different methods of stylus calibration. The positional jitter amounted to 0.14 mm(A) and 0.08 mm(B). A relative positional error of 0.96 mm +/- 0.68 mm, range -0.06 mm; 2.23 mm(A) and 1.14 mm +/- 0.78 mm, range -3.72 mm; 1.57 mm(B) for a given distance of 50 mm was found. The relative rotation error was found to be 0.51 degrees (A)/0.04 degrees (B). The most relevant distortion caused by metallic objects results from SST 416. The maximum error 4.2 mm(A)/ > or = 100 mm(B) occurs when the rod is close to the sensor(20 mm). While (B) is more sensitive with respect to metallic objects, (A) is less accurate concerning orientation measurements. (B) showed a systematic error when distances are calculated.

Biomechanical Phenomena↗

Robot-assisted biopsy using ultrasound guidance: initial results from in vitro tests.

The purpose of this study was to develop a robotic system for ultrasound (US)-guided biopsy and to validate the feasibility, accuracy and efficacy using phantom tests. Twenty peas (mean diameter 9.3+/-0.1 mm) embedded within a gel-phantom were selected for biopsy. Once the best access was defined, the position of the US transducer was recorded by an optical tracking system. Positional data of the transducer and the corresponding US image were transferred to the roboter planning system (LINUX-based industrial PC equipped with video capture card). Once the appropriate position, angulation and pitch were calculated, the robotic arm moved automatically with seven degrees-of-freedom to the planned insertion path, aiming the needle-positioning unit at the center of the target. Then, the biopsy was performed manually using a coaxial technique. The length of all harvested specimens was measured, and the deviation of the actual needle tract from the center of the target was evaluated sonographically. In all targets, the biopsy specimen (mean length 5+/-1.2 mm) was harvested with only one needle pass required The mean deviation of the needle tip from the center of the target was 1.1+/-0.8 mm. Robotic assisted biopsies in-vitro using US-guidance were feasible and provided high accuracy.

Biopsy↗

Introducing a system for automated control of rotation axes, collimator and laser adjustment for a medical linear accelerator.

Mechanical stability and precise adjustment of rotation axes, collimator and room lasers are essential for the success of radiotherapy and particularly stereotactic radiosurgery with a linear accelerator. Quality assurance procedures, at present mainly based on visual tests and radiographic film evaluations, should desirably be little time consuming and highly accurate. We present a method based on segmentation and analysis of digital images acquired with an electronic portal imaging device (EPID) that meets these objectives. The method can be employed for routine quality assurance with a square field formed by the built-in collimator jaws as well as with a circular field using an external drill hole collimator. A number of tests, performed to evaluate accuracy and reproducibility of the algorithm, yielded very satisfying results. Studies performed over a period of 18 months prove the applicability of the inspected accelerator for stereotactic radiosurgery.

Algorithms↗

Computer-enhanced stereoscopic vision in a head-mounted operating binocular.

Based on the Varioscope, a commercially available head-mounted operating binocular, we have developed the Varioscope AR, a see through head-mounted display (HMD) for augmented reality visualization that seamlessly fits into the infrastructure of a surgical navigation system. We have assessed the extent to which stereoscopic visualization improves target localization in computer-aided surgery in a phantom study. In order to quantify the depth perception of a user aiming at a given target, we have designed a phantom simulating typical clinical situations in skull base surgery. Sixteen steel spheres were fixed at the base of a bony skull, and several typical craniotomies were applied. After having taken CT scans, the skull was filled with opaque jelly in order to simulate brain tissue. The positions of the spheres were registered using VISIT, a system for computer-aided surgical navigation. Then attempts were made to locate the steel spheres with a bayonet probe through the craniotomies using VISIT and the Varioscope AR as a stereoscopic display device. Localization of targets 4 mm in diameter using stereoscopic vision and additional visual cues indicating target proximity had a success rate (defined as a first-trial hit rate) of 87.5%. Using monoscopic vision and target proximity indication, the success rate was found to be 66.6%. Omission of visual hints on reaching a target yielded a success rate of 79.2% in the stereo case and 56.25% with monoscopic vision. Time requirements for localizing all 16 targets ranged from 7.5 min (stereo, with proximity cues) to 10 min (mono, without proximity cues). Navigation error is primarily governed by the accuracy of registration in the navigation system, whereas the HMD does not appear to influence localization significantly. We conclude that stereo vision is a valuable tool in augmented reality guided interventions.

Depth Perception↗

Impaired gastric emptying and altered intragastric meal distribution in diabetes mellitus related to autonomic neuropathy?

Previous studies in diabetic patients suggested a relationship between delayed gastric emptying and increased ingesta retention in either proximal or distal stomach, but the determinants underlying these abnormalities remained obscure. We aimed at assessing the impact of cardiovascular autonomic neuropathy, blood glucose concentration, long-term glycemic control, and other factors in 34 type I and 43 type II diabetic patients (ages 21-67 and 34-81 years, respectively). Emptying was slower (P < 0.04) in type I diabetic patients than in 20 healthy control subjects (ages 23-63 years). Patients with autonomic neuropathy (N = 45) had slower gastric emptying (P < 0.02) and retained more in the distal stomach (P < 0.0001) than patients without neuropathy (N = 32). Multiple regression analyses revealed that slow emptying and increased distal retention were significantly associated with autonomic neuropathy (P < 0.043, P < 0.0002), whereas blood glucose, glycemic control, diabetes duration, age, and other factors had no discernible influence. Thus, both slow emptying and increased distal ingesta retention seem primarily referable to autonomic neuropathy.

Adult↗

Computer-aided placement of endosseous oral implants in patients after ablative tumour surgery: assessment of accuracy.

The objective of this study was to evaluate the feasibility and accuracy of a novel surgical computer-aided navigation system for the placement of endosseous implants in patients after ablative tumour surgery. Pre-operative planning was performed by developing a prosthetic concept and modifying the implant position according to surgical requirements after high-resolution computed tomography (HRCT) scans with VISIT, a surgical planning and navigation software developed at the Vienna General Hospital. The pre-operative plan was transferred to the patients intraoperatively using surgical navigation software and optical tracking technology. The patients were HRCT-scanned again to compare the position of the implants with the pre-operative plan on reformatted CT-slices after matching of the pre- and post-operative data sets using the mutual information-technique. A total of 32 implants was evaluated. The mean deviation was 1.1 mm (range: 0-3.5 mm). The mean angular deviation of the implants was 6.4 degrees (range: 0.4 degrees - 17.4 degrees, variance: 13.3 degrees ). The results demonstrate, that adequate accuracy in placing endosseous oral implants can be delivered to patients with most difficult implantologic situations.

Dental Implantation, Endosseous↗

Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible.

The overall accuracy of a novel surgical computer-aided navigation system for placement of endosseous implants was evaluated. Five dry cadaver mandibles were scanned using high resolution computed tomography (HRCT). The position of four interforaminal dental implants was planned on the computer screen and transferred to the cadaver mandibles using VISIT, a surgical navigation software developed at the Vienna General Hospital. The specimens were HRCT-scanned again to compare the position of the implants with the preoperative plan on reformatted slices after matching of the pre- and postoperative data sets using the mutual information technique. The overall accuracy was 0.96 +/- 0.72 mm (range 0.0-3.5 mm). No perforation of the mandibular cortex or damage to the mandibular canal occurred. We conclude that computer-aided implant surgery can reach a level of accuracy where further clinical developments are feasible.

Cadaver↗

A head-mounted operating binocular for augmented reality visualization in medicine--design and initial evaluation.

Computer-aided surgery (CAS), the intraoperative application of biomedical visualization techniques, appears to be one of the most promising fields of application for augmented reality (AR), the display of additional computer-generated graphics over a real-world scene. Typically a device such as a head-mounted display (HMD) is used for AR. However, considerable technical problems connected with AR have limited the intraoperative application of HMDs up to now. One of the difficulties in using HMDs is the requirement for a common optical focal plane for both the realworld scene and the computer-generated image, and acceptance of the HMD by the user in a surgical environment. In order to increase the clinical acceptance of AR, we have adapted the Varioscope (Life Optics, Vienna), a miniature, cost-effective head-mounted operating binocular, for AR. In this paper, we present the basic design of the modified HMD, and the method and results of an extensive laboratory study for photogrammetric calibration of the Varioscope's computer displays to a real-world scene. In a series of 16 calibrations with varying zoom factors and object distances, mean calibration error was found to be 1.24 +/- 0.38 pixels or 0.12 +/- 0.05 mm for a 640 x 480 display. Maximum error accounted for 3.33 +/- 1.04 pixels or 0.33 +/- 0.12 mm. The location of a position measurement probe of an optical tracking system was transformed to the display with an error of less than 1 mm in the real world in 56% of all cases. For the remaining cases, error was below 2 mm. We conclude that the accuracy achieved in our experiments is sufficient for a wide range of CAS applications.

Calibration↗

Evaluation of a miniature electromagnetic position tracker.

The advent of miniaturized electromagnetic digitizers opens a variety of potential clinical applications for computer aided interventions using flexible instruments; endoscopes or catheters can easily be tracked within the body. With respect to the new applications, the systematic distortions induced by various materials such as closed metallic loops, wire guides, catheters, and ultrasound scan heads were systematically evaluated in this paper for a new commercial tracking system. We employed the electromagnetic tracking system Aurora (Mednetix/CH, NDI/Can); data were acquired using the serial port of a PC running SuSE Linux 7.1 (SuSE, Gmbh, Nürnberg). Objects introduced into the digitizer volume included wire loops of different diameters, wire guides, optical tracking tools, an ultrasonic (US) scan head, an endoscope with radial ultrasound scan head and various other objects used in operating rooms and interventional suites. Beyond this, we determined the influence of a C-arm fluoroscopy unit. To quantify the reliability of the system, the miniaturized sensor was mounted on a nonmetallic measurement rack while the transmitter was fixed at three different distances within the digitizer range. The tracker was shown to be more sensitive to distortions caused by materials close to the emitter (average distortion error 13.6 mm +/- 16.6 mm for wire loops positioned at a distance between 100 mm and 200 mm from the emitter). Distortions caused by materials near the sensor (distances smaller than 100 mm) are small (typical error 2.2 mm +/- 1.9 mm). The C-arm fluoroscopy unit caused considerable distortions and limits the reliability of the tracker (distortion error 18.6 mm +/- 24.9 mm). Distortions resulting from the US scan head are high at distances smaller than about 100 mm from the emitter. The distortions also increase when the scan head is positioned horizontally and close to the sensor (average error 4.1 mm +/- 1.5 mm when the scan head is positioned within a distance of 100 mm from the sensor). The distortions are slightly higher when the ultrasound machine is switched on. We also evaluated the influence of common medical instruments on distance measurements. For these measurements the average deviation from the known distance of 200 mm amounted to 3.0 mm +/- 1.5 mm (undistorted distance measurement 1.5 mm +/- 0.3 mm). The deviations also depend on the relative orientation between emitter and sensor. The results demonstrate that the miniature tracking system opens up new perspectives with regard to surgery applications where a flexible instrument is to be tracked within the body. Significant distortions caused by metallic objects only occur in the worst cases, for example, in the presence of a closed, unisiolated wire loop or a C-arm fluorescence unit close to the emitter and which can be avoided by suitable usage.

Calibration↗