PubMed Health⌕ Search

Biomedical subjects

Helmut Sachs

Publications and source records attributed to Helmut Sachs.

3 recordsLinked to original sources

Visual resolution with retinal implants estimated from recordings in cat visual cortex.

We investigated cortical responses to electrical stimulation of the retina using epi- and sub-retinal electrodes of 20-100 microm diameter. Temporal and spatial resolutions were assessed by recordings from the visual cortex with arrays of microelectrodes and optical imaging. The estimated resolutions were approximately 40 ms and approximately 1 degrees of visual angle. This temporal resolution of 25 frames per second and spatial resolution of about 0.8 cm at about 1m and correspondingly 8 cm at 10 m distance seems sufficient for useful object recognition and visuo-motor behavior in many in- and out-door situations of daily life.

Action Potentials↗

In vivo assessment of subretinally implanted microphotodiode arrays in cats by optical coherence tomography and fluorescein angiography.

BACKGROUND: Following multiple promising investigations into restoration of vision in degenerative retinal disease by implantation of a sub- or epiretinal prosthesis, the step to clinical use in humans is impending. In this study we intended to establish optical coherence tomography (OCT) and fluorescein angiography (FA) first in research animals for noninvasive assessment of the condition of the posterior pole of eyes after intraocular implant surgery. METHODS: Three adult cats that had undergone subretinal implant surgery were evaluated by OCT and FA between 1 and 470 days postoperatively. Eight adult cats served as control. In addition histology was performed. RESULTS: In all three cats OCT demonstrated stable positioning of the implants in the subretinal space during the complete examination period. Transient retinal edema was found in the early postoperative period but decreased during follow-up. The retina over the implants was well attached at all times in cats 1 and 2; however, in cat 3 localized retinal detachment was demonstrated. FA showed intact retinal vasculature over the subretinal implant in high detail without interference from choroidal background fluorescence. CONCLUSIONS: OCT and FA have been fruitfully applied to cats to assess the morphological and circulatory conditions of the neuroretina and of its interface with the subretinal implant. The techniques may therefore provide a tool for objective, noninvasive in vivo evaluation of eyes that have undergone subretinal implant surgery, both in research animals and in humans.

Animals↗

Biostability of micro-photodiode arrays for subretinal implantation.

Micro-photodiode arrays based on semiconductor chip technology are being developed to replace degenerated photoreceptor cells in the retina. Electric current is generated in tiny micro-photodiodes and delivered to the adjacent tissue by micro-electrodes. One of the main requirements of a sub-retinal implantable device is long-term stability versus corrosion in vivo (biostability). Biostability of micro-photodiode arrays (MPDA) was investigated in vitro and in vivo. No significant damage was found on chips immersed for up to 21 months in saline solution. Under in vivo conditions, however, the silicon oxide passivation layer of the chip was dissolved within a period of about 6-12 months. Subsequently, the underlying silicon was corroded. In contrast, stimulation electrodes consisting of titanium nitride were well preserved both in vitro and in vivo. The deterioration of the electrical properties of the micro-photodiodes correlated with the morphological damage observed. Strategies aiming at the development of an improved biostable encapsulation of neurotechnological implants have to be investigated and will be discussed briefly.

Animals↗