Comparing electron ionization high-resolution and electron capture low-resolution mass spectrometric determination of polybrominated diphenyl ethers in plasma, serum and milk.

Gas chromatography coupled to low-resolution mass spectrometry with electron capture negative ionization as detection mode (GC-LRMS (ECNI)) has been compared to gas chromatography coupled to high-resolution mass spectrometry using electron ionization as detection mode (GC-HRMS (EI)) for determination of polybrominated diphenyl ethers (PBDEs) in biological samples. Extracts of 5.0 g plasma, serum and milk samples were analyzed using both methods. The GC-LRMS (ECNI) and GC-HRMS (EI) systems were found to be equally well suited for determination of PBDEs in the biological samples, as well as in standard solutions, with respect to response, detection limits and repeatability at the pg-level. The estimated limits of detection (LOD) in milk extracts ranged from 0.3-0.6 pg PBDE/g milk and 0.4-0.7 pg PBDE/g milk, for the GC-LRMS (ECNI) and GC-HRMS (EI) systems, respectively. The method repeatability including sample preparation was in the range 4.7-8.4% and 0.6-10% relative standard deviation (RSD) for the GC-LRMS (ECNI) and GC-HRMS (EI) systems, respectively.

Calibration↗

A new method for determination of halogenated flame retardants in human milk using solid-phase extraction.

A method has been developed for quantitation of a selection of halogenated flame retardants in human milk. The method has been validated for seven polybrominated diphenyl ethers (PBDEs), BDE-28, BDE-47, BDE-99, BDE-100, BDE-153, BDE-154, and BDE-183, and the halogenated phenols 2,4,6-tribromophenol (TriBP), pentabromophenol (PeBP), tetrachlorobisphenol-A (TCBP-A), and tetrabromobisphenol-A (TBBP-A). The sample preparation includes solid-phase extraction using an N-vinylpyrrolidone-divinylbenzene copolymer with on-column lipid decomposition followed by additional cleanup on sulfuric acid-silica columns and methylation of the phenolic compounds. Separation and detection were performed by gas chromatography-electron capture mass spectrometry, using a 5% phenyl 95% dimethylpolysiloxane column. The method has been validated in the range of 1.8-180 pg/g milk for most of the halogenated flame retardants. The average absolute recoveries were from 49 to 83%, and the average recoveries with respect to internal standards were in the range of 53 to 121%. Estimated limits of detection were in the range of 0.3 to 1.0 pg/g milk using a sample size of 5 g for all compounds, except TCBP-A, for which the limit of detection was estimated to 6.7 pg/g milk.

Female↗