17 recordsLinked to original sources

Functional renal MR imaging: an overview.

Due to its complementary information to standard morphological imaging, functional renal magnetic resonance imaging is a rapid growing field of radiology. This pictorial essay provides a comprehensive overview of state-of-the-art functional renal imaging techniques including renal magnetic resonance angiography, first pass renal perfusion, assessment of renal function, blood-oxygen level dependent imaging of the kidneys and diffusion-weighted imaging of the kidneys including diffusion-tensor imaging of the kidneys. Basic technical concepts for all sequences are laid out. As renal perfusion imaging becomes a clinical routine examination, particular attention is given to renal perfusion measurements and the potential postprocessing approaches. Advantages and drawbacks of the published methods are illustrated. Future applications of functional renal imaging are presented.

Contrast Media↗

Effects of injection rate and dose on image quality in time-resolved magnetic resonance angiography (MRA) by using 1.0M contrast agents.

In time-resolved MRA (TR MRA), injection parameters and contrast agent (CA) dose are important factors influencing image quality. In this study, three different injection schemes with different CA volumes were evaluated in 12 healthy volunteers. Injection rates between 0.2 and 0.8 ml/s were evaluated with CA volumes of 10 and 20 ml. To measure circulatory parameters, cine cardiac MRI was performed before each exam. Spatial resolution could be reduced to 2 x 1.4 x 2 mm3, temporal resolution was 2.25 s/frame. To exclude signal saturation at high CA concentrations, a phantom with fixed CA concentrations was placed in the field of view. SNR was measured, and the area under the curve of the arterial signal of the different injection schemes was calculated. Results showed the largest diagnostic window at a relatively slow injection rate of 0.4 ml/s and a CA volume of 10 ml. Circulatory parameters have an important impact on CA arrival, so delay times have to be set depending on these parameters.

Adult↗

Pulmonary circulation: contrast-enhanced 3.0-T MR angiography--initial results.

PURPOSE: To prospectively evaluate the technical feasibility of both high-spatial-resolution and time-resolved contrast material-enhanced magnetic resonance (MR) angiography of the pulmonary circulation at 3.0 T. MATERIALS AND METHODS: All examinations were HIPAA compliant. After institutional review board approval and written informed consent, time-resolved and high-spatial-resolution three-dimensional contrast-enhanced MR angiography of the pulmonary circulation was performed with a 3.0-T MR system in 31 adults (13 men, 18 women; age range, 29-87 years old): 22 volunteers and nine patients (two with mediastinal masses, seven with pulmonary arterial hypertension [PAH]). The image quality of pulmonary arterial branches and parenchymal enhancement conspicuity were evaluated independently by two radiologists. The signal-to-noise ratio and quantitative analysis of perfusion parameters was performed. Statistical analysis of data was performed by using Wilcoxon rank sum test and two-sample Student t test, and interobserver variability was tested with kappa coefficient. RESULTS: Visualization up to fourth-order pulmonary arterial branches was observed on time-resolved MR angiograms and that up to fifth-order branches was observed on high-spatial-resolution MR angiograms, with diagnostic-quality blood vessel definition and good interobserver agreement. Evaluation of parenchymal enhancement and semiquantitative analysis of perfusion parameters yielded dynamic information in all subjects. Comparative analysis of definition scores for fourth- and fifth-order pulmonary arterial branches, parenchymal enhancement, the time lag between the pulmonary arterial and parenchymal enhancement, and all of the calculated perfusion indices in patients with PAH showed statistically significant differences from volunteers (P < .05). CONCLUSION: Three-dimensional contrast-enhanced MR angiography of the pulmonary circulation was feasible at 3.0 T and provided high vascular morphologic detail and dynamic functional information. Clearly detectable abnormalities were present in patients with PAH.

Adult↗

MRA of abdominal vessels: technical advances.

Magnetic resonance angiography (MRA) in general and MRA of the abdominal vessels in particular have undergone substantial improvements in the past 5 years triggered by the introduction and application of parallel imaging (PI), new sequence techniques such as centric k-space trajectories and undersampling, dedicated contrast agents and clinical high-field scanners. All of these techniques have the potential to improve image quality and resolution or decrease the image acquisition time. However, each of them has its own specific advantages and drawbacks. This review describes the main technical innovations and focuses on the impact these developments may have on abdominal MRA. Special consideration is given to the interaction of these various technical advances. The clinical value of advanced MRA techniques is discussed and illustrated by characteristic cases.

Abdomen↗

High-resolution renal MRA: comparison of image quality and vessel depiction with different parallel imaging acceleration factors.

PURPOSE: To investigate the image quality and vessel depiction of renal MRA with integrated parallel imaging techniques (iPAT) using acceleration factors of 2 and 3. MATERIALS AND METHODS: In this prospective study renal MRA was performed on 14 and 12 patients with acceleration factors of 3 and 2, respectively. For the MRA a 3D-GRE sequence with an acquired spatial resolution of 0.9 x 0.8 x 1.0 mm(3) was applied (TR/TE = 3.79 msec/1.39 msec, FOV = 400 mm x 320 mm, acquired matrix = 512 x 384, flip angle = 25 degrees) on a 32-channel 1.5T MR scanner. The acquisition time was 26 seconds with iPAT 2, and 19 seconds with iPAT3. All parameters other than acquisition time and acceleration factor were kept constant. To assess the signal-to-noise ratio (SNR) we performed repetitive phantom measurements using iPAT 2 and 3. The images were rated by two radiologists in terms of noise, artifacts, and the quality of vessel depiction for the proximal, segmental, and subsegmental renal artery. A Mann-Whitney U-test and kappa-test were used for statistical analysis. RESULTS: SNR decreased significantly with iPAT 3 in the phantom measurements. The two readers found no difference in noise, but significantly fewer artifacts with iPAT 3. The depiction of segmental vessels was significantly better for both readers with iPAT 3, and the subsegmental vessels were rated significantly better by one reader. iPAT 3 also resulted in a better interreader agreement. CONCLUSION: The use of iPAT 3 for renal MRA enables a better depiction of the distal parts of the renal artery. The decrease in SNR is not diagnostically impairing.

Adult↗

Dynamic pulmonary perfusion and flow quantification with MR imaging, 3.0T vs. 1.5T: initial results.

PURPOSE: To prospectively evaluate the technical feasibility and relative performance of pulmonary time-resolved MR angiography (MRA) and pulmonary artery (PA) flow quantification at 3.0T vs. 1.5T. MATERIALS AND METHODS: Time-resolved contrast-enhanced (CE) MRA of the pulmonary circulation, and flow quantification of the main PA (MPA) were performed in 14 consecutive adult healthy volunteers at both 1.5 and 3.0 Tesla with nearly identical sequence parameters. Image quality, signal-to-noise ratio (SNR), and quantitative indices of pulmonary perfusion, flow, and velocity were evaluated and compared at both field strengths. RESULTS: Time-resolved pulmonary MRA, perfusion, and flow quantification were successfully performed at both magnetic fields. The results of pulmonary perfusion and flow indices were comparable at both magnetic fields, with no statistically significant difference. The SNR values for vascular structures were higher at 3.0T vs. 1.5T (P = 0.001). The SNR values and the definition scores for parenchymal enhancement were significantly lower (P = 0.008 and 0.001, respectively) at 3.0T. CONCLUSION: Time-resolved pulmonary MRA, perfusion, and flow quantification at 3.0T was feasible, with comparable results to 1.5T. The lower parenchymal enhancement at 3.0T is believed to reflect increased susceptibility effects at higher magnetic fields. Further work is needed to fully exploit the potential of pulmonary perfusion imaging at 3.0T and to address the current limitations.

Adult↗

Renal perfusion: comparison of saturation-recovery TurboFLASH measurements at 1.5T with saturation-recovery TurboFLASH and time-resolved echo-shared angiographic technique (TREAT) at 3.0T.

PURPOSE: To investigate the dependence of semiquantitative renal perfusion parameters on the acquisition technique and field strength used. MATERIALS AND METHODS: After intravenous injection of 7-mL Gd-chelates, high-temporal-resolution turbo fast low-angle shot (TurboFLASH) renal perfusion measurements were performed on eight healthy volunteers at 1.5T and another eight healthy volunteers at 3.0T. Another eight healthy volunteers were examined at 3.0T using time-resolved echo-shared angiographic technique (TREAT) after bolus administration of 7-mL Gd-chelates with a temporal resolution of 1.4 seconds. Analysis of the first-pass perfusion data yielded the following semiquantitative renal perfusion indices: mean transit time (MTT), time to peak (TTP), maximal upslope (MUS), and maximal signal intensity (MSI). RESULTS: MTT and TTP did not show significant differences between the different techniques. MSI and MUS were significantly (P < or = 0.002) higher with TREAT (591.1 a.u./second and 103.5 a.u./second) than with TurboFLASH at both field strengths (1.5T: 400.5 a.u./second and 65.4 a.u./second; 3.0T: 362.2 a.u./second and 68.7 a.u./second). CONCLUSION: Semiquantitative renal perfusion measurements are feasible with time-resolved echo-shared sequences and TurboFLASH techniques. While MTT and TTP appear to be independent of the technique and field strength applied, MUS and MSI are higher with TREAT.

Adult↗

Analysis of cardiac function--comparison between 1.5 Tesla and 3.0 Tesla cardiac cine magnetic resonance imaging: preliminary experience.

PURPOSE: We sought to assess the feasibility of magnetic resonance imaging to evaluate cardiac function at 3.0 T compared with 1.5 T. MATERIAL AND METHODS: In a prospective intraindividual comparative study, 12 volunteers (range, 18-54 years), and 2 patients (range, 43-53 years) underwent cardiac cine magnetic resonance at both 3.0 T and 1.5 T. Data were acquired both with a steady-state free precession sequence (SSFP) and a spoiled gradient echo (SGE) sequence. If necessary, a frequency scout was used to correct for off-resonance artifacts. For both SSFP and SGE imaging, 6-mm thick retrospectively EKG-gated short axis views were acquired with equal matrix size (192 x 163) and comparable repetition time (TR). Cardiac function parameters were determined manually by a single investigator. Cardiac function parameters, signal to noise ratio (SNR), contrast to noise ratio (CNR), and the presence of artifacts were compared between the 2 magnetic field strengths. For statistical analysis, a Pearson's correlation coefficient was calculated, and a paired Student t test was used to test statistical significance. RESULTS: Very good correlations between cardiac function parameters at 1.5 T and 3.0 T (r > 0.84, P < 0.0011) were obtained. Compared with SGE, SSFP more frequently was prone to artifacts. With SSFP/SGE at 3.0 T, a SNR gain of 9.4/16% was achieved compared with 1.5 T. CONCLUSION: Functional cardiac cine magnetic resonance imaging can be regarded as equally accurate at 3.0 T compared with 1.5 T. Compared with SSFP imaging, the SGE sequence benefits more from higher field strengths and is less affected by artifacts.

Adolescent↗

Time-resolved contrast enhanced magnetic resonance angiography of the head and neck at 3.0 tesla: initial results.

OBJECTIVES: We sought to implement and evaluate a high-performance, extended field of view protocol for time-resolved contrast-enhanced magnetic resonance imaging (CEMRA) of the carotid circulation by using a dedicated neurovascular (NV) array coil. MATERIALS AND METHODS: A total of 16 adult volunteers and 20 clinical patients with suspected cerebrovascular disease (15 male, 21 female, 25-82 years of age) were scanned with a fast 3D MRA sequence (TR/TE: 2.16/1 milliseconds, sampling BW: 1090 Hz/pixel), with echo-sharing and parallel acquisition. All studies were performed on a 3.0 T MR system using an 8-channel neurovascular array coil. After injection of 6 mL of gadodiamide at 3 mL/s, a coronal 3D data set with in-plane resolution of 1 x 1.3 was implemented for 10 consecutive measurements each 1.8 seconds apart. The subjects subsequently underwent high spatial-resolution (in-plane: 0.8 x 0.9) CEMRA for comparative analysis. The quality of segmental arterial anatomy and the presence and degree of the arterial stenosis were evaluated by 2 neuroradiologists. The interobserver variability was tested by kappa statistics and comparative analysis between the TR-CEMRA and high spatial-resolution CEMRA was evaluated by mean of the Spearman rank correlation coefficient. RESULTS: Craniocervical arteries were visualized with good image quality and definition in the diagnostic range. Occlusive disease was detected in 42 (reader A) and 44 (reader B) arterial segments with excellent interobserver agreement (kappa =0.89; 95% confidence interval 0.82-0.96). There was a significant correlation between the TR-CEMRA and high spatial-resolution CEMRA (Rs = 0.91 and 0.93, for readers A and B, respectively) for the degree of stenosis. Three aneurysms, 3 AVMs, 1 AV-fistula, and 2 subclavian steals were detected by both observers and were confirmed by correlative imaging. CONCLUSION: Time-resolved CEMRA at 3.0 T is reliable and versatile, providing 3-dimensional time-resolved data sets with high spatial (in plane: 1.3 x 1 mm2) and temporal (1.8 seconds) resolution over a large field of view. The higher signal-to-noise ratio gain at 3.0 T can be used effectively to improve performance of fast imaging and to support aggressive parallel acquisition protocols, as in the present study. Further clinical studies are required to establish the range of applications and the accuracy of the technique.

Adult↗

High spatial-resolution CE-MRA of the carotid circulation with parallel imaging: comparison of image quality between 2 different acceleration factors at 3.0 Tesla.

PURPOSE: We sought to evaluate and compare the image quality and vessel delineation of the carotid arteries with high spatial-resolution contrast-enhanced MRA (CE-MRA) at 3.0 T using integrated parallel acquisition (iPAT) with acceleration factors of 2 and 4. MATERIALS AND METHODS: Using an 8-channel neurovascular array coil, we performed prospective high-spatial resolution CE-MRA at 3.0 T of the head and neck on 24 patients (11 men, 13 women, ages 37-89) with suspected arterio-occlusive disease who were assigned randomly to 2 groups. Twelve patients (group A) were examined with a 3D-GRE sequence using iPAT with acceleration factor of 2. For the next 12 patients (group B) a near-identical sequence with an acceleration factor of 4 was applied. Higher iPAT factors were used to increase the spatial-resolution while keeping scan time unchanged. Two volunteers were scanned by both protocols. Phantom measurements were performed to assess the signal-to-noise ratio (SNR). The presence of artifact, noise, image quality of the arterial segments, and the presence and degree of arterial stenosis were evaluated independently by 2 radiologists. Statistical analysis of data was performed by using Wilcoxon rank sum test and 2-sample Student t test (P < 0.05 was indicative a statistically significant difference). The interobserver variability was tested by kappa coefficient. RESULTS: SNR values were significantly lower when iPAT with acceleration factor of 4 was used (P < 0.001). There was no significant difference between 2 groups in regards to image noise (P = 0.67) and artifact (P = 0.8). Both readers visualized the majority of carotid circulation with good image quality in both groups. For smaller intracranial arteries, such as the second-division of anterior and middle cerebral artery, anterior communicating artery, and superior cerebellar artery, the image quality and vessel delineation was significantly better at an iPAT factor of 4 (P < 0.01). The overall interobserver agreement for both the vessel depiction, and detection of arterial stenoses was higher in group B compared with group A. CONCLUSION: Use of parallel acquisition techniques with a high acceleration factor (iPAT-4) results in superior depiction of small intracranial arterial segments. Imaging at higher magnetic field strength, in addition to the use of an optimized 8-channel array coil, provides sufficient SNR to support faster parallel acquisition protocols, leading to improved spatial-resolution. More extensive clinical studies are warranted to establish the range of applications and confirm the accuracy of the technique.

Adult↗

Renal artery stenosis: functional assessment with dynamic MR perfusion measurements--feasibility study.

PURPOSE: To prospectively assess feasibility of renal magnetic resonance (MR) perfusion measurement method based on turbo fast low-angle shot sequences for grading effect of renal artery stenosis (RAS) on parenchymal perfusion. MATERIALS AND METHODS: Institutional review board approved this study, and patients gave written consent. Seventy-three patients (34 male, 39 female; age range, 17-84 years) who were clinically suspected of having RAS underwent contrast material-enhanced (gadodiamide) saturation-recovery turbo fast low-angle shot imaging for measurement of renal perfusion and high-spatial-resolution MR angiography for RAS detection and grading. Degree of stenosis was evaluated as high grade (>/=75% stenosis), low to intermediate grade (>0% to <75% stenosis), or absent. High temporal resolution of the turbo fast low-angle shot sequence allowed acquisition of an exact first-pass tracing of the contrast agent bolus from which a signal intensity (SI)-time curve was derived. On the basis of this curve, mean transit time (MTT) of the contrast agent bolus, maximal upslope (MUS) of the curve, maximum SI, and time to SI peak (TTP) were calculated with a gamma variate fit. Wilcoxon rank sum test, Pearson product moment correlation, and paired t test were used for statistical analysis. RESULTS: Twenty-four renal arteries had high-grade RAS, 12 renal arteries had low- to intermediate-grade RAS, and 104 renal arteries had no RAS. Significant differences between patients without stenoses or with low- to intermediate-grade stenoses and patients with high-grade stenoses were found for MTT, MUS, and TTP (P < .001). Perfusion parameters were correlated with patients' serum creatinine levels, and significant correlations were found for MTT (r = 0.41), MUS (r = 0.48), and TTP (r = 0.4), with P < .001. CONCLUSION: MR perfusion parameters can be used to assess effect of RAS on parenchymal perfusion. Perfusion measurements reflect renal function as measured with serum creatinine levels.

Adolescent↗

High-spatial-resolution MR angiography of renal arteries with integrated parallel acquisitions: comparison with digital subtraction angiography and US.

PURPOSE: To retrospectively compare three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography, performed with an integrated parallel acquisition technique for high isotropic spatial resolution, with selective digital subtraction angiography (DSA) and intravascular ultrasonography (US) for accuracy of diameter and area measurements in renal artery stenosis. MATERIALS AND METHODS: The study was approved by the institutional review board, and consent was obtained from all patients. Forty-five patients (17 women, 28 men; mean age, 62.2 years) were evaluated for suspected renal artery stenosis. Three-dimensional gadolinium-enhanced MR angiograms were acquired with isotropic spatial resolution of 0.8 x 0.8 x 0.9 mm in 23-second breath-hold with an integrated parallel acquisition technique. In-plane diameter of stenosis was measured along vessel axis, and perpendicular diameter and area of stenosis were assessed in cross sections orthogonal to vessel axis, on multiplanar reformations. Interobserver agreement between two radiologists in measurements of in-plane and perpendicular diameters of stenosis and perpendicular area of stenosis was assessed with mean percentage of difference. In a subset of patients, degree of stenosis at MR angiography was compared with that at DSA (n = 20) and intravascular US (n = 11) by using Bland-Altman plots and correlation analyses. RESULTS: Mean percentage of difference in stenosis measurement was reduced from 39.3% +/- 78.4 (standard deviation) with use of in-plane views to 12.6% +/- 9.5 with use of cross-sectional views (P < .05). Interobserver agreement for stenosis grading based on perpendicular area of stenosis was significantly better than that for stenosis grading based on in-plane diameter of stenosis (mean percentage of difference, 15.2% +/- 24.2 vs 54.9% +/- 186.9; P < .001). Measurements of perpendicular area of stenosis on MR angiograms correlated well with those on intravascular US images (r(2) = 0.90). CONCLUSION: Evaluation of cross-sectional images reconstructed from high-spatial-resolution three-dimensional gadolinium-enhanced MR renal angiographic data increases the accuracy of the technique and decreases interobserver variability.

Adult↗

Comprehensive magnetic resonance imaging of the small and large bowel using intraluminal dual contrast technique with iron oxide solution and water in magnetic resonance enteroclysis.

OBJECTIVE: The objective of this study was to improve delineation of small and large bowel (SB, LB) anatomy and pathology with postoperative or complex multisegmental inflammatory changes using dual-contrast-technique (DCT) for magnetic resonance enteroclysis (MRE) with luminal contrast media of opposed signal characteristics. MATERIALS AND METHODS: Sixty patients underwent MRE with iron oxide-based negative contrast in the SB. Thirty patients received additional rectal instillation of water for positive contrast (DCT). Two observers evaluated the degree of distention and the ease of identification of bowel anatomy and pathologies (none n=22, stenosis n=16, abscess n=4, fistulae n=5, postoperative changes and adhesions n=13) using a 4-point scale. Mann-Whitney U-test and kappa statistics were applied. RESULTS: LB and the terminal ileum were significantly better distended and identified with DCT (P<or=0.0001; P=0.034). Interobserver agreement improved with DCT for all pathologies except for "prestenotic dilatation." CONCLUSIONS: Comprehensive MR imaging of SB and LB with DCT improves the identification of modified anatomy and most pathologies in inflammatory and postsurgical bowel.

Adolescent↗

Renal disease: value of functional magnetic resonance imaging with flow and perfusion measurements.

PURPOSE: To differentiate healthy kidneys from diseased kidneys, we propose a combined magnetic resonance (MR) examination that includes measurements of renal arterial blood flow and parenchymal perfusion. MATERIALS AND METHODS: A total of 130 kidneys (patients/healthy volunteers: 83/47) were examined using renal artery MR flow measurements and renal parenchymal perfusion measurements, as well as contrast-enhanced MR angiography. Cine phase-contrast-flow measurements were performed using an ECG-gated fast low angle shot pulse sequence; perfusion was measured with an arterial spin labeling flow-sensitive alternating inversion recovery technique. Contrast-enhanced MR angiography was performed with a fast 3D gradient echo sequence in a single breath hold. For evaluation, kidneys were divided into groups based on nephrologic diagnosis of the patient. Recursive partitioning and Wilcoxon rank-sum tests were used to separate the different groups. RESULTS: Significant differences in mean renal artery flow and parenchymal perfusion were found in kidneys with renal artery stenosis as well as parenchymal disease as compared with healthy kidneys. Using a classification tree derived from the recursive partitioning, a specificity of 99% and sensitivity of 69% with a positive/negative predictive value of 97%/84% was achieved for the separation of healthy kidneys from kidneys with vascular, parenchymal or combined disease. The overall accuracy was 88%. CONCLUSION: The combination of cine PC flow measurements and MR perfusion measurements offers a comprehensive assessment of both renovascular and renoparenchymal disease and provide a noninvasive approach to differentiate between these kidneys and normal kidneys.

Adult↗