Immunogenicity and safety of an inactivated hepatitis A vaccine administered concomitantly with diphtheria-tetanus-acellular pertussis and haemophilus influenzae type B vaccines to children less than 2 years of age.

OBJECTIVE: The availability of a hepatitis A virus vaccine for infant and early childhood immunization could reduce the transmission of hepatitis A virus in the United States. This study evaluated the immunogenicity and safety of a hepatitis A virus vaccine (Havrix, GlaxoSmithKline Biologicals, Rixensart, Belgium) administered concomitantly with diphtheria-tetanus-acellular pertussis and Haemophilus influenzae type b vaccines to children < 2 years. METHODS: In this open, comparative, multicenter study, 1084 healthy children aged 11 to 25 months were allocated (4:4:3:3:4 ratio) to 5 treatment groups based on age and previous vaccination history. Subjects 11 to 13 months of age received 2 doses of hepatitis A virus vaccine 6 months apart (N = 243). Subjects aged 15 to 18 months received 2 doses of hepatitis A virus vaccine 6 months apart (N = 241); or hepatitis A virus vaccine, diphtheria-tetanus-acellular pertussis, and H influenzae type b at month 0 and the second dose of hepatitis A virus vaccine 6 months later (N = 183); or diphtheria-tetanus-acellular pertussis and H influenzae type b at month 0 and hepatitis A virus vaccine at months 1 and 7 (N = 175). Subjects 23 to 25 months of age received hepatitis A virus vaccine at months 0 and 6 (N = 242). Immune responses were measured at baseline and 30 days after vaccine doses, and solicited and unsolicited adverse events were collected. RESULTS: After 2 doses of hepatitis A virus vaccine, all of the subjects in all of the groups were seropositive. Coadministration of hepatitis A virus vaccine with diphtheria-tetanus-acellular pertussis and H influenzae type b vaccines did not impact the immunogenicity of the 3 vaccines, except for the antipertussis toxoid vaccine response, which was slightly decreased. Hepatitis A virus vaccine was well tolerated in children 11 to 25 months of age. CONCLUSION: The administration of 2 doses of hepatitis A virus vaccine on a 0- and 6-month schedule starting at 11 to 13 months of age or at 15 to 18 months of age was as immunogenic and well tolerated as the administration of 2 doses in children 2 years of age. Immune responses to diphtheria-tetanus-acellular pertussis and H influenzae type b either given alone or coadministered with hepatitis A virus vaccine were similar except for antipertussis toxoid response.

Antibody Formation↗

Screening healthy infants for iron deficiency using reticulocyte hemoglobin content.

CONTEXT: Current clinical practice relies on hemoglobin to detect iron deficiency, which misses infants not yet anemic and places them at higher risk for neurocognitive impairment. Reticulocyte hemoglobin content (CHr) has never been compared with hemoglobin for screening healthy infants. OBJECTIVES: To evaluate CHr for detecting iron deficiency without anemia in healthy 9- to 12-month-old infants and to compare CHr with hemoglobin in screening for iron deficiency in this population. A secondary objective was to explore the association between CHr and subsequent development of anemia. DESIGN, SETTING, AND PATIENTS: A prospective observational cohort study of 202 healthy 9- to 12-month-old infants from an urban, hospital-based, primary care clinic in Boston, Mass, who were screened for iron deficiency between June 2000 and April 2003, and followed up for a median of 5.6 months. MAIN OUTCOME MEASURES: Iron deficiency (transferrin saturation <10%) and anemia (hemoglobin <11 g/dL). RESULTS: Of 202 infants enrolled, 23 (11.4%) had iron deficiency and 6 (3%) had iron deficiency and anemia. Iron-deficient and non-iron-deficient infants had significantly different values for all measured hematological and biochemical markers for iron deficiency. Optimal CHr cutoff for detecting iron deficiency was 27.5 pg (sensitivity, 83% and specificity, 72%); a hemoglobin level of less than 11 g/dL resulted in a sensitivity of 26% and a specificity of 95%. Reticulocyte hemoglobin content was more accurate overall than hemoglobin was for detecting iron deficiency (area under the receiver operating characteristic curve, 0.85 vs 0.73; P = .007). A CHr of less than 27.5 pg without anemia at initial screening was associated with subsequent anemia when screened again in the second year of life (risk ratio, 9.1; 95% confidence interval, 1.04-78.9; P = .01). CONCLUSIONS: A CHr of less than 27.5 pg is a more accurate hematological indicator of iron deficiency compared with hemoglobin of less than 11 g/dL in these healthy 9- to 12-month-old infants. Further studies are warranted to determine whether CHr should be the preferred screening tool in the early detection of iron deficiency in infants.

Anemia, Iron-Deficiency↗

Effect of monophosphoryl lipid A (MPL) on T-helper cells when administered as an adjuvant with pneumocococcal-CRM197 conjugate vaccine in healthy toddlers.

As new vaccines are developed, novel adjuvants may play an important role in eliciting an effective immune response. We evaluated the safety and adjuvant properties of monophosphoryl lipid A (MPL in 129 healthy toddlers immunized with two doses of nine-valent pneumococcal-CRM(197) protein conjugate vaccine (PCV9) combined with 10, 25, or 50 micro g of MPL with or without alum (AlPO(4)). Vaccine-specific humoral and cell-mediated responses were examined following the second dose of study vaccine. All doses of MPL were well-tolerated and a dose-dependent effect of MPL on specific cellular responses was observed. The 10 micro g MPL dose significantly enhanced CRM(197)-specific T-cell proliferation (P=0.02) and interferon-gamma (INF-gamma) production (P=0.009) compared to responses of controls who received PCV9 with AlPO(4). In contrast, CRM(197)-specific T-cell proliferation and interferon-gamma production of the 50 micro g MPL/AlPO(4) group were decreased when compared to controls although these differences did not reach statistical significance. IL-5 and IL-13 responses after immunization showed a similar pattern with increased production in the 10 micro g MPL group and decreased production in the 50 micro g MPL/AlPO(4) group compared to controls. There were no differences in serum IgG antibody concentrations to the nine vaccine pneumococcal capsular polysaccharides and carrier protein between the MPL-containing and control vaccine groups. These findings demonstrate a dose-dependent effect of MPL on T-helper cell type 1 (TH-1) responses to the carrier protein and also suggest an effect on T-helper cell type 2 (TH-2) responses.

Adjuvants, Immunologic↗