PubMed Health⌕ Search

Biomedical subjects

Henry W Glindmeyer

Publications and source records attributed to Henry W Glindmeyer.

4 recordsLinked to original sources

Case definitions for chronic obstructive pulmonary disease.

The objective of this study was to evaluate the definitions for classification of chronic obstructive pulmonary disease (COPD) recommended by the American Thoracic Society (ATS) and the Global Initiative for Chronic Obstructive Lung Disease (GOLD). Using data from the U.S. population-based third National Health and Nutrition Examination Survey (NHANES III), we compared the number of individuals in the U.S. population who met definitions of airflow obstruction based on the fixed ratio of FEV /FVC < 0.70 criterion and on the ATS lower 95% confidence limit (lower limits of normal LLN) criterion. Further, we evaluated the definitions in the context of physician-diagnosed obstructive airways diseases and respiratory symptoms. In comparison to the FEV1/FVC < LLN and FEV1 < 100% predicted definition, the fixed ratio-based definition for mild COPD underestimates airflow obstruction by 29% in 20-49-year-olds and overestimates it by 58% in 50-80-year-olds. In comparison to the FEV1/FVC < LLN and FEV1 < LLN definition, the fixed ratio-based definition for moderate COPD underestimates airflow obstruction by 31% in 20-49-year-olds and overestimates it by 37% in 50-80 year olds. Based on our estimation, approximately 0.9 million (26%) of symptomatic individuals out of the 3.6 million U.S. adults aged 20-49 years who have airflow obstruction (FEV1/FVC < LLN and FEV1 < LLN definition) may have undiagnosed respiratory disease. In conclusion, using the FEV1/FVC < 0.70 criterion will substantially under-diagnose airway obstruction in younger individuals and substantially over-diagnose COPD in older individuals.

Adult↗

Longitudinal limits of normal decline in lung function in an individual.

OBJECTIVES: The objectives of this study were to propose a method of calculating longitudinal limits of normal decline (LND) in forced expiratory volume in 1 second to identify individuals with an excessive decline in lung function and to compare the method with other published LND methods. METHODS: We used longitudinal data from 11 workplace-based spirometric monitoring programs conducted from 1987 to 2001 on 12,729 workers to evaluate effectiveness of each LND method in identifying a "true" excessive decline in forced expiratory volume in 1 second defined using two criteria: slope >60 mL/year or >90 mL/year estimated over 5 or more years of follow up. RESULTS: In comparison to the LND proposed by the American College of Occupational and Environmental Medicine, the proposed method had 5.0 to 2.7 times higher sensitivity over years 1 through 5 for the >60-mL/yr criterion. CONCLUSIONS: The proposed LND method was more effective than the other methods for identifying excessive declines.

Adult↗

On-filter determination of collected wood dust by diffuse reflectance infrared Fourier-transform spectroscopy (DRIFTS).

A new analytical technique based on DRIFTS spectroscopy has been developed for the specific and sensitive determination of size-fractionated wood dust from 37 mm glass fiber filter samples collected with the Respicon sampler. A translational diffuse reflectance apparatus was modified to accept filter samples by incorporating a special filter holder in the sample stage and a clockwork motor to drive the translational stage during infrared scanning, thus providing an average analysis across the filter face. Filter samples were pre-treated with ethyl acetate to uniformly redeposit dust onto the filter and extract potential chemical interferences. Two absorbance maxima (1251 and 1291 cm(-1)), corresponding to the cellulose content of the wood, were suitable for quantitation of wood dust. Analysis of seven species of wood at 1291 cm(-1) showed an equivalent quantitative response for all species except maple. The response at 1251 cm(-1) was more variable across species but more sensitive for the softwoods. There was a statistically significant effect of particle size on the analytical response, so that analytical standards should be matched to the samples in terms of particle size distribution. Analytical limit of detection was approximately 0.08 mg of wood dust per sample with overall precision of about 6%. Comparison of DRIFTS and gravimetric analyses of 51 pure wood dust samples ranging from about 0.2 to 2 mg yielded a slope of 1.08 and r2 equal to 0.9. Other particulate contaminants common in the industrial wood processing industry showed little or no interference with the determination of wood dust by this method.

Air Pollutants, Occupational↗

Spray-painting and chronic airways obstruction.

BACKGROUND: The aim was to investigate the respiratory response of HDI-based paint aerosol within the context of the protection afforded by current exposure guidelines. METHODS: A cross-sectional study of 240 painters spraying polyurethane enamels was undertaken at four aircraft maintenance plants. Questionnaire and spirometric data were related to gravimetric measures of cumulative total and respirable paint aerosol (TPA and RPA) and estimated isocyanate in total and respirable aerosols (TIA and RIA). RESULTS: Average cumulative exposures in mg/m(3)-years +/- SD were 159.0 +/- 115.2 TPA, 19.1 +/- 13.8 RPA, 15.8 +/- 11.5 TIA, and 1.9 +/- 1.4 RIA. After adjusting for smoking and asthma symptoms, higher exposures were associated with statistically significant reduction in expiratory flowrates. Significant smoking-related reductions were also observed, without exposure interactions. CONCLUSIONS: These results suggest important respiratory effects from exposures to spray paint aerosols at levels generally in compliance with existing standards for otherwise unregulated particulates and for the isocyanate component of the paint.

Adult↗