PubMed Health⌕ Search

Biomedical subjects

Henry W K Luk

Publications and source records attributed to Henry W K Luk.

5 recordsLinked to original sources

A preliminary report on patient acceptance of a novel intra-oral lubricating device for the management of radiotherapy-related xerostomia.

Management of radiotherapy-related xerostomia is difficult. Saliva substitutes are helpful but the effects are short-lived. The purpose of the study was to develop a prototype intra-oral lubricating device for the management of radiotherapy-related xerostomia and to evaluate patient acceptance. An intra-oral lubricating device was fabricated that incorporated a reservoir in the palatal vault and permitted slow release of saliva substitute by the patient. Preliminary clinical testing was done in five patients with radiotherapy-related xerostomia. A measure incorporating seven questions was used to explore patient acceptance. The device was simple to fabricate using materials available in a technical laboratory. All patients were able to wear the device for at least 4 h per day throughout the test period. The device was considered easy to use and clean. Some impairment of speech and chewing was noted although this appeared to be related to the bulkiness of the reservoir. General oral comfort was improved due to the lubricating effect. The bulk of the reservoir was reduced as a consequence of patient feedback. The design addressed key problems associated with previous lubricating systems. Patient reports on oral functioning with the device in situ provided pivotal information on the device's utility.

Cranial Irradiation↗

A double casting technique to minimize distortion when constructing fixed partial dentures on implants.

The casting of extensive implant superstructures that have a good passive fit may be technically demanding. A simple, 2-stage casting technique is presented that avoids common problems associated with the casting of large superstructures. The fabrication of a 7-unit metal-ceramic screw-retained fixed partial denture supported by 5 implants is used to illustrate this technique.

Dental Abutments↗

Precision surgical template for implant placement: a new systematic approach.

The importance of a precise surgical template for implant placement cannot be overstated. The radiographic template carries both clinical and radiographic information for the planning of fixture angulation and location. This article describes a systematic approach to the fabrication of a dual-purpose radiographic surgical template. The simple steps result in the accurate transfer of radiographic information to the surgical template with no need for complex equipment or maneuvers. key words: dental implants, implant placement, radiographic template, surgical template

Dental Implantation, Endosseous↗

Threshold contrast ratio and masking ability of porcelain veneers with high-density alumina cores.

PURPOSE: The purposes of this study were to: (1) investigate the correlation between the color difference of bilayer porcelain veneers over white and black backgrounds (deltaE1) and their opacity (contrast ratios); (2) determine whether there is a recommendable threshold contrast ratio above which the color difference is clinically acceptable (when deltaE < or = 5); and (3) compare the ability of porcelain veneers to mask a color change from white to black backgrounds (deltaE1) and their ability to mask a color change from white to clinically discolored teeth (deltaE2). MATERIALS AND METHODS: Forty-four maxillary anterior teeth of eight patients with severe tetracycline discoloration were prepared for bilayer porcelain veneers in shade A2 porcelain. The cores were 0.25 mm thick. The color (CIE L*a*b*) and reflectance (Y) of the midbuccal region of each veneer were measured over white and black backgrounds using a colorimeter under artificial daylight. The veneers were bonded to discolored teeth, and their color was measured after 1 week. RESULTS: The mean color difference deltaE1 was 10.6 (SD 2.6). The mean contrast ratio was 0.75 (SD 0.1). There was a close and statistically significant correlation between deltaE1 and contrast ratio. The determined threshold contrast ratio was 0.91. The mean color difference deltaE2 was 11.6 (SD 5.5). A paired t test showed no difference between deltaE1 and deltaE2. CONCLUSION: There was a significant correlation between the masking ability of veneers (deltaE1) and their opacity (contrast ratio). There was no significant difference in the ability of the porcelain veneers in masking a color change from white to black backgrounds compared to their ability to mask the color change from white to the discolored teeth.

Aluminum Oxide↗

Comparison of the retentive characteristics of cobalt-chromium and commercially pure titanium clasps using a novel method.

This study aimed to compare the retentive forces of cast cobalt-chromium (Co-Cr) and commercially pure titanium (cpTi) clasps. A clasp assembly comprising a pair of symmetrical clasps was made to fit the opposite halves of a hardened stainless-steel sphere. This twin clasp was designed to counterbalance the tipping forces when the clasp assembly was drawn from the sphere. A total of 120 clasp assemblies were fabricated in cast Co-Cr and cpTi and placed at undercut depths of 0.25 mm, 0.50 mm, and 0.75 mm (n = 20 for each). For Co-Cr clasps, the retentive forces at these undercuts depths were 2.34 +/- 0.23 N, 4.65 +/- 0.35 N, and 7.56 +/- 0.50 N, respectively. The corresponding retentive forces for cpTi clasps were 1.24 +/- 0.13 N, 2.34 +/- 0.23 N, and 3.70 +/- 0.27 N. The retentive force of cpTi clasps was approximately half that of Co-Cr clasps for the same undercut depth.

Chromium Alloys↗