PubMed Health⌕ Search

Biomedical subjects

Hideaki Hisamoto

Publications and source records attributed to Hideaki Hisamoto.

At least 19 recordsLinked to original sources

Capillary-assembled microchip as an on-line deproteinization device for capillary electrophoresis.

A capillary-assembled microchip (CAs-CHIP), prepared by simply embedding square capillaries in a lattice polydimethylsiloxane (PDMS) channel plate with the same channel dimensions as the outer dimensions of the square capillaries, has been used as a diffusion-based pretreatment attachment in capillary electrophoresis (CE). Because the CAs-CHIPs employ square-section channels, diffusion-based separation of small molecules from sample solutions containing proteins is possible by using the multilayer flow formed in the square section channel. When a solution containing high-molecular-weight and low-molecular-weight species makes contact with a buffer solution, the low-molecular-weight species, which have larger diffusion coefficients than the high-molecular-weight species, can be collected in a buffer-solution phase. The collected solution containing the low-molecular-weight species is introduced into the separation capillary to be analyzed by CE. This type of system can be used for CE analysis in which pretreatment is required to remove proteins. In this work a fluorescently labeled protein and rhodamine-based molecules were chosen as model species and a feasibility study was performed.

Journal Article↗

Measurement of monomolecular binding constants of neutral phenols into the beta-cyclodextrin by continuous frontal analysis in capillary and microchip electrophoresis via a competitive assay.

Measurement of binding constant by chip electrophoresis is a very promising technique for the high throughput screening of non-covalent interactions. Among the different electrophoretic methods available that yield the binding parameters, continuous frontal analysis is the most appropriate for a transposition from capillary electrophoresis (CE) to microchip electrophoresis. Implementation of this methodology in microchip was exemplified by the measurement of inclusion constants of 2-naphtalenesulfonate and neutral phenols (phenol, 4-chlorophenol and 4-nitrophenol) into beta-cyclodextrin by competitive assays. The issue of competitor choice is discussed in relation to its appropriateness for proper monitoring of the interaction.

Electrophoresis, Capillary↗

Integration of valving and sensing on a capillary-assembled microchip.

A simple integration of both flow control valves and a reaction-based sensing function on a single microchip was performed by using capillary-assembled microchip (CAs-CHIP: Hisamoto, H.; Nakashima, Y.; Kitamura, C.; Funano, S.-i.; Yasuoka, M.; Morishima, K.; Kikutani, Y.; Kitamori, T.; Terabe, S. Anal. Chem. 2004, 76, 3222-3228.). In contrast to the previously reported on-chip valving systems, where the simple valving functions were integrated, our system can integrate not only valving function but also many other chemical functions to perform a complex chemical operation on a single microchip. Here, an enzymatic reaction-based readout system is employed as an example. A square capillary immobilizing N-isopropylacrylamide polymer monolith (referred to as "valving capillary") is used as a thermoresponsive "valving part" and the immobilizing enzyme-modified glycidyl methacrylate polymer monolith (referred to as "sensing capillary") is used as a "sensing part" of the CAs-CHIP. These capillaries are embedded into a lattice microchannel network fabricated on poly(dimethylsiloxane), which has the same channel dimensions as the outer dimensions of the square capillaries. After bonding, a small Peltier device (2 mm x 2 mm) for temperature control is placed on the embedded valving capillaries to control fluid flow. Using this for heating or cooling, fast operation times of 1.4 and 3.2 s for opening and closing valves, respectively, are successfully achieved. Finally, two valving capillaries are independently controlled to trap sample solution within a bypass channel, where the enzyme-immobilized capillary is embedded, and then enzymatic reaction-based sensing of chemical species is performed as an example. The fundamental characteristics of the valve-integrated microchip are fully investigated, and an application to the analysis of an enzyme substrate by using two independent valving capillaries and a sensing capillary is demonstrated.

Journal Article↗

Microfluidic chip toward cellular ATP and ATP-conjugated metabolic analysis with bioluminescence detection.

In this article, a microfluidic platform integrating capillary electrophoresis and bioluminescence (BL) detection that was fabricated in poly(dimethylsiloxane) (PDMS) with lab-on-a-chip technology was demonstrated for cellular metabolic analyses. A microchannels network, "cross combining with Y", was designed to perform on-chip sample preparation, separation, and BL detection of ATP and ATP-conjugated metabolites, using firefly luciferin-luciferase BL system. A dynamic modification of the channel wall of PDMS proved to be crucial to reverse the direction of electroosmotic flow (EOF), which was uniquely achieved by a prewash cycle with a cationic surfactant didodecyldimethylammonium bromide. The influences of surfactant on the EOF and BL reaction were also investigated. Quantitative analyses revealed a dynamic linear range over 2 orders of magnitude for ATP, with a detection limit down to submicromolar (midattomole). The method was validated by measuring cellular ATP of E. coli. with direct on-chip cell lysis. Further work was emphasized on ATP-conjugated metabolite analysis, using galactose as an example. Assays of galactose in human urine samples confirmed the reliability of the protocol, which revealed good prospect of this platform for ATP-conjugated submetabolomic profiling.

Adenosine Triphosphate↗

Capillary-assembled microchip for universal integration of various chemical functions onto a single microfluidic device.

A novel concept for assembling various chemical functions onto a single microfluidic device is proposed. The concept, called a capillary-assembled microchip, involves embedding chemically functionalized capillaries into a lattice microchannel network fabricated on poly(dimethylsiloxane) (PDMS). The network has the same channel dimensions as the outer dimensions of the capillaries. In this paper, we focus on square capillaries to be embedded into a PDMS microchannel network having a square cross section. The combination of hard glass square capillary and soft square PDMS channel allows successful fabrication of a microfluidic device without any solution leakage, and which can use diffusion-based two-solution mixing. Two different types of chemically modified capillaries, an ion-sensing capillary and a pH-sensing capillary, are prepared by coating a hydrophobic plasticized poly(vinyl chloride) membrane and a hydrophilic poly(ethyleneglycol) membrane containing functional molecules onto the inner surface of capillaries. Then, they are cut into appropriate lengths and arranged on a single microchip to prepare a dual-analyte sensing system. The concept proposed here offers advantages inherent to using a planar microfluidic device and of chemical functionality of immobilized molecules. Therefore, we expect to fabricate various types of chemically functionalized microfluidic devices soon.

Journal Article↗

Micro wet analysis system using multi-phase laminar flows in three-dimensional microchannel network.

A three-dimensional microchannel network with two-level crossings of channels was constructed in a glass microchip by sandwiching an insulating glass plate between two glass plates with microchannels followed by thermal bonding. Pressure-driven stable multi-phase laminar flows inside the three-dimensional channel network were realized by balancing flow rates of syringe pumps. Micro unit operations for mixing, reaction, solvent extraction, and detection were properly arranged in the multi-phase laminar flows, so that four parallel analyses, comprising twenty unit operations in total, could be integrated onto a single chip. Two chelating reagents and two sample solutions containing heavy metal ions (Fe(ii) or Co(ii)) were mixed and reacted in four different combinations using the three-dimensional channel network. After chelating reactions were completed, post processing (solvent extraction or addition of acid) was applied to each solution stream to remove the interferences of coexisting metal ions. Finally, target metal complexes were detected using a thermal lens microscope (TLM). Integrity of the micro system was confirmed by qualitative analysis of Fe(ii) and Co(ii). This is the first example of continuous flow chemical processing utilizing multi-phase laminar flow realized in a three-dimensional channel network.

Glass↗

Characterization of molecular transport in poly(dimethylsiloxane) microchannels for electrophoresis fabricated with synchrotron radiation-lithography and UV-photolithography.

In the present paper, a study was undertaken of molecular transport in ploy(dimethylsiloxane) microchannels that were fabricated by ultraviolet (UV)-photolithography and synchrotron radiation (SR)-lithography characterized and compared for microchip capillary electrophoresis by evaluating in-channel molecular dispersion. A fluorescent tag, sulforhodamine B was used as the probing molecule. It was found that microchannels made by SR-lithography fabrication were superior to those made by UV-photolithography fabrication in terms of molecular transport performance. A deep insight into surface conditions characterized by scanning electron microscopy suggested it was related to the difference in surface roughness. Chromatographic retention in electropherograms further supported such a conclusion, which depended on the phase ratio of the channel surface. The results revealed for PDMS microchannels in this work were in good agreement with the phenomenon found for glass microchannels in the literature.

Dimethylpolysiloxanes↗

Subsecond separation of cellular flavin coenzymes by microchip capillary electrophoresis with laser-induced fluorescence detection.

In this article, it was demonstrated that a subsecond separation of cellular metabolites such as riboflavin (RF), flavin mononucleotide (FMN), and flavin-adenine dinucleotide (FAD) was achieved using microchip capillary electrophoresis with laser-induced fluorescence detection. The influences of crucial parameters that governed analysis time (e.g., channel length and electric field for separation) and separation resolution (e.g., sample size) were investigated, both in theoretical aspects and experimental practice. Quantitative analyses were performed that exhibited linear dynamic range of two orders of magnitude, with calculated detection limits of 34, 201, and 127 nM for RF, FAD, and FMN, respectively. To test the validity of the method, it was successfully applied to characterize several recombinant flavin-binding domains in a human neuronal nitric oxide synthase.

Coenzymes↗

Phase-transfer alkylation reactions using microreactors.

Phase-transfer alkylation in a microreactor proceeds smoothly, and the reaction has been found to be more efficient than that in a round-bottomed flask with vigorous stirring; we have observed by an optical microscope study that an interfacial area provided by organic and aqueous phases is more extended in a microreactor.

Journal Article↗

Microchip-based chemical and biochemical analysis systems.

This review focuses on chemical and biochemical analysis systems using pressure-driven microfluidic devices or microchips. Liquid microspace in a microchip has several characteristic features, for example, short diffusion distances, high specific interfacial area and small heat capacity. These characteristics are the key to controlling micro unit operations and constructing new integrated chemical systems. By combining multiphase laminar flow and the micro unit operations, such as mixing, reaction, extraction and separation, continuous flow chemical processing systems are realized in the microchip format. By applying these concepts, several different analysis systems were successfully integrated on a microchip. In this paper, we introduce the microchip-based chemical systems for wet analysis of cobalt ion, multi-ion sensors, immunoassay, and cellular analysis.

Animals↗

Chemicofunctional membrane for integrated chemical processes on a microchip.

Here we report a design and synthesis of a chemically functional polymer membrane by an interfacial polycondensation reaction and multilayer flow inside a microchannel. Single and parallel dual-membrane structures are successfully prepared by using organic/aqueous two-layer flow and organic/aqueous/organic three-layer flow inside the microchannel followed by an interfacial polycondensation reaction. By using the inner-channel membrane, permeation of ammonia species through the inner-channel membrane is successfully achieved. Furthermore, horseradish peroxidase is immobilized on one side of the membrane surface to integrate the chemical transform function onto the inner-channel membrane. Here substrate permeation through the membrane and subsequent chemical transformation at the membrane surface are realized. The polymer membrane prepared inside the microchannel has an important role in ensuring stable contact of different phases such as gas/liquid or liquid/ liquid and the permeation of chemical species through the membrane. Furthermore, membrane surface modification chemistry allows chemical transformation of permeated chemical species. These methods are expected to lead to development of complicated and sophisticated chemical systems involving membrane permeation and chemical reactions.

Journal Article↗

Chemical processing on microchips for analysis, synthesis, and bioassay.

This review describes our recent research on miniaturization of chemical systems. We have developed a miniaturization methodology based on pressure-driven multiphase laminar flow and a highly sensitive detection tool, the thermal lens microscope. Some representative applications of the methodology in the fields of analysis, synthesis, and bioassay are described.

Microscopy↗

An interface chip connection between capillary electrophoresis and thermal lens microscope.

A thermal lens microscope (TLM) detection of capillary electrophoresis (CE) utilizing microchip technology was developed. Fused-silica capillaries with an inner diameter of 50 microm were directly connected to a microchannel in a microchip. The detection limit by TLM was estimated as 2.8 x 10(-7) absorbance by measuring pure water. The detection limit of derivatized amino acids determined by CE-TLM was estimated as 2.4 x 10(-8) M, which was 100 times lower than that of conventional absorbance detection.

Amino Acids↗

Integration of chemical and biochemical analysis systems into a glass microchip.

This review focuses on the integration of chemical and biochemical analysis systems into glass microchips for general use. By combining multiphase laminar flow driven by pressure and micro unit operations, such as mixing, reaction, extraction and separation, continuous-flow chemical processing systems can be realized in the microchip format, while the application of electrophoresis-based chip technology is limited. The performances of several analysis systems were greatly improved by microchip integration because of some characteristics of microspace, i.e., a large specific interface area, a short molecular diffusion time, a small heat capacity and so on. By applying these concepts, several different analysis systems, i.e., wet analysis of cobalt ion, multi-ion sensor, immunoassay, and cellular analysis, were successfully integrated on a microchip. These microchip technologies are promising for meeting the future demands of high-throughput chemical processing.

Biosensing Techniques↗

Glass microchip with three-dimensional microchannel network for 2 x 2 parallel synthesis.

An integrated multireactor system for 2 x 2 parallel organic synthesis has been developed on a single glass microchip. Three-dimensional channel circuits in the chip were fabricated by laminating three glass plate layers. The fabrication method is a straightforward extension of the conventional one, and topological equivalence for any three-dimensional circuits can be constructed easily with it. 2 x 2 phase-transfer amide formation reactions, which constitute a simple model for combinatorial synthesis, were successfully carried out on the microchip, and the integrity of the three-dimensional circuits was confirmed. Combinatorial chemistry with multi-microreactors, in conjunction with a high-throughput screening method based on micro-TAS technologies, is expected to provide an efficient tool for drug discovery.

Journal Article↗

Pile-up glass microreactor.

We made a 'pile-up' microreactor in which ten levels of microchannel circuits were integrated to form a single glass entity. Solutions were distributed to each layer via cylindrical holes with a diameter much larger than that of the microchannel. Fabrication of the pile-up reactor was completed using only conventional photolithography, wet etching and thermal bonding techniques, and no special facilities or instruments were required. An amide formation reaction between amine in aqueous solution and acid chloride in organic solution was carried out using the pile-up reactor. The yield of the amide formation reaction is dependent on the size of the specific surface area between the two solutions, and the small space inside the microchannels is good for acquiring a large specific surface area without any stirring processes. The maximum throughput for the ten-layered pile-up reactor was ten times larger than that of a single-layered one, yet the reaction yield was still high. Productivity of the pile-up reactor for the reaction was as high as on a gram per hour scale. This value suggests that many conventional plants producing fine chemicals can be replaced by microreactors through the numbering-up technology.

Journal Article↗

Three-layer flow membrane system on a microchip for investigation of molecular transport.

A stable three-layer flow system, water/organic solvent/water, has been successfully applied for the first time in a microchannel to get rapid transport through an organic liquid membrane. In the continuous laminar flow region, the analyte (methyl red) was rapidly extracted across the microchannel from the donor to the acceptor phase through the organic solvent phase (cyclohexane). Thermal lens microscopy was used to monitor the process. The thickness of the organic phase, sandwiched by the two aqueous phases, was approximately 64 microm, and it was considered as a thin liquid organic membrane. Permeability studies showed the effects of molecular diffusion, layer thickness, and organic solvent-water partition coefficient on the molecular transport. In the microchip, complete equilibration was achieved in several seconds, in contrast to a conventionally used apparatus, where it takes tens of minutes. The thickness of the organic and aqueous boundary layers was defined as equal to the microchannel dimensions, and the organic solvent-water partition coefficient was determined on a microchip using the liquid/liquid extraction system. Experimental data on molecular transport across the organic membrane were in agreement with the calculated permeability based on the three-compartment water/organic solvent/water model. This kind of experiment can be performed only in a microspace, and the system can be considered as a potential biological membrane for future in vitro study of drug transport.

Azo Compounds↗

Stabilization of liquid interface and control of two-phase confluence and separation in glass microchips by utilizing octadecylsilane modification of microchannels.

We demonstrated a liquid/liquid and a gas/liquid two-phase crossing flow in glass microchips. A 250-microm-wide microchannel for aqueous-phase flow was fabricated on a top glass plate. Then, as a way to utilize the surface energy difference for stable phase confluence and separation, a 250-microm-wide microchannel for organic-phase (or gas-phase) flow was fabricated on a bottom glass plate and the wall was chemically modified by octadecylsilane (ODS) group. The top and bottom plates were sealed only by pressure. A microchannel pattern was designed so that the two phases made contact at the crossing point of the straight microchannels. The crossing point was observed with an optical microscope. Results showed that the ODS modification of the microchannel wall clearly improved stability of the interface between the two fluids. Pressure difference between fluids was measured and the interface of water and nitrobenzene was stable for the pressure difference from +300 Pa to -200 Pa. The pressure drop in a countercurrent flow configuration was also estimated, and the pressure difference required to realize the counter current flow was less than the allowable pressure range. Finally, we discussed the advantages of utilizing this approach.

Journal Article↗