PubMed Health⌕ Search

Biomedical subjects

Hideaki Kumahara

Publications and source records attributed to Hideaki Kumahara.

3 recordsLinked to original sources

The use of uniaxial accelerometry for the assessment of physical-activity-related energy expenditure: a validation study against whole-body indirect calorimetry.

Assessing the total energy expenditure (TEE) and the levels of physical activity in free-living conditions with non-invasive techniques remains a challenge. The purpose of the present study was to investigate the accuracy of a new uniaxial accelerometer for assessing TEE and physical-activity-related energy expenditure (PAEE) over a 24 h period in a respiratory chamber, and to establish activity levels based on the accelerometry ranges corresponding to the operationally defined metabolic equivalent (MET) categories. In study 1, measurement of the 24 h energy expenditure of seventy-nine Japanese subjects (40 (SD 12) years old) was performed in a large respiratory chamber. During the measurements, the subjects wore a uniaxial accelerometer (Lifecorder; Suzuken Co. Ltd, Nagoya, Japan) on their belt. Two moderate walking exercises of 30 min each were performed on a horizontal treadmill. In study 2, ten male subjects walked at six different speeds and ran at three different speeds on a treadmill for 4 min, with the same accelerometer. O2 consumption was measured during the last minute of each stage and was expressed in MET. The measured TEE was 8447 (SD 1337) kJ/d. The accelerometer significantly underestimated TEE and PAEE (91.9 (SD 5.4) and 92.7 (SD 17.8) % chamber value respectively); however, there was a significant correlation between the two values (r 0.928 and 0.564 respectively; P<0.001). There was a strong correlation between the activity levels and the measured MET while walking (r(2) 0.93; P<0.001). Although TEE and PAEE were systematically underestimated during the 24 h period, the accelerometer assessed energy expenditure well during both the exercise period and the non-structured activities. Individual calibration factors may help to improve the accuracy of TEE estimation, but the average calibration factor for the group is probably sufficient for epidemiological research. This method is also important for assessing the diurnal profile of physical activity.

Acceleration↗

The difference between the basal metabolic rate and the sleeping metabolic rate in Japanese.

Previous studies have demonstrated the difference between the basal metabolic rate (BMR) and the sleeping metabolic rate (SMR): however, the difference in the Japanese population has not yet been explored. This study examined the relationship between the BMR and SMR in ninety-four healthy Japanese subjects (37 males and 57 females, 39 +/- 12 y of age and 22.0 +/- 7.4% body fat) in a respiratory chamber. The SMR was significantly lower than the BMR (1416 +/- 245 vs. 1492 +/- 256 kcal/d): however, there was a highly significant correlation between the two (r = 0.867; p < 0.001). The ratio of SMR/BMR largely varied among individuals (0.95 +/-0.08, 8.4% of the coefficient of variation). The ratio was significantly lower in males than in females (0.93 +/- 0.10 vs. 0.97 +/- 0.06, p < 0.05). None of the anthropometric measures (age, weight, body mass index, body surface area or percent body fat) correlated with the ratio. These results showed that SMR was 95%, of BMR on average in a healthy Japanese group. However, when applied over a longer time period (24 h or more), the difference tends to become negligible for most analyses in a group. Although the difference between SMR and BMR will induce a 5% gap of physical activity level defined as the total energy expenditure divided by the BMR or SMR, this factor seems to have little practical importance in epidemiological research.

Adult↗