Quantitative mapping of basal and vasareactive cerebral blood flow using split-dose 123I-iodoamphetamine and single photon emission computed tomography.

A new method has been developed for diffusible tracers, to quantify CBF at rest and after pharmacological stress from a single session of dynamic scans with dual bolus administration of a radiotracer. The calculation process consisted of three steps, including the procedures of incorporating background radioactivity contaminated from the previous scan. Feasibility of this approach was tested on clinical SPECT studies on 16 subjects. Two sequential SPECT scans, 30 min apart, were carried out on each subject, after each of two split-dose administrations of 111 MBq IMP. Of these, 11 subjects received acetazolamide at 10 min before the second IMP injection. Additional PET scans were also carried out on 6 subjects on a separate day, at rest and after acetazolamide administration. The other 5 subjects were scanned only at rest during the whole study period. Quantitative CBF obtained by this method was in a good agreement with those determined with PET (y(ml/100 g/min)=1.07x(ml/100 g/min)-1.14, r=0.94). Vasareactivity was approximately 40% over the whole cerebral area on healthy controls, which was consistent with a literature value. Reproducibility of CBF determined in the rest-rest study was 1.5+/-5.7%. Noise enhancement of CBF images, particularly the second CBF, was reduced, providing reasonable image quality. Repeat assessment of quantitative CBF from a single session of scans with split-dose IMP is accurate, and may be applied to clinical research for assessing vascular reactivity in patients with chronic cerebral vascular disease.

Aged↗

Estimation of oxygen metabolism in a rat model of permanent ischemia using positron emission tomography with injectable15O-O2.

The threshold of cerebral blood flow (CBF) into infarction in rats has been indicated to be similar to that in patients. However, CBF does not reflect metabolic function, and so estimations of oxygen metabolism have been required. Here, we estimated changes in oxygen metabolism after occluding the right middle cerebral artery (MCA) in rats using an injectable (15)O-O(2) we developed. A decrease in CBF (left: 0.67+/-0.22 mL/min/g, right: 0.44+/-0.17 mL/min/g, P<0.05) and compensatory increase in the oxygen extraction fraction (OEF) (left: 0.42+/-0.13, right: 0.50+/-0.19, P<0.05) were observed at 1-h after occlusion. In contrast, a marked decrease in CBF and the cerebral metabolic rate for oxygen and a collapse of the compensatory OEF mechanism were found at 24 h after occlusion. Injectable (15)O-O(2) could be used to reliably estimate oxygen metabolism in an infarction rat model with positron emission tomography.

Animals↗

Gene transfer of hepatocyte growth factor gene improves learning and memory in the chronic stage of cerebral infarction.

There is no specific treatment to improve the functional recovery in the chronic stage of ischemic stroke. To provide the new therapeutic options, we examined the effect of overexpression of hepatocyte growth factor (HGF) in the chronic stage of cerebral infarction by transferring the HGF gene into the brain using hemagglutinating virus of Japan envelope vector. Sixty rats were exposed to permanent middle cerebral artery occlusion (day 1). Based on the sensorimotor deficits at day 7, the rats were divided equally into control vector or HGF-treated rats. At day 56, rats transfected with the HGF gene showed a significant recovery of learning and memory in Morris water maze tests (control vector 50+/-4 s; HGF 33+/-5 s; P<0.05) and passive avoidance task (control vector 132.4+/-37.5 s; HGF 214.8+/-26.5 s; P<0.05). Although the total volume of cerebral infarction was not related to the outcome, immunohistochemical analysis for Cdc42 and synaptophysin in the peri-infarct region revealed that HGF enhanced the neurite extension and increased synapses. Immunohistochemistry for glial fibriary acidic protein revealed that the formation of glial scar was also prevented by HGF gene treatment. Additionally, the number of the arteries was increased in the HGF group at day 56. These data demonstrated that HGF has a pivotal role for the functional recovery after cerebral infarction through neuritogenesis, improved microcirculation, and the prevention of gliosis. Our results also provide evidence for the feasibility of gene therapy in the chronic stage of cerebral infarction.

Animals↗

Widespread decrease of nicotinic acetylcholine receptors in Parkinson's disease.

OBJECTIVE: Nicotinic acetylcholine receptors have close interactions with the dopaminergic system and play critical roles in cognitive function. The purpose of this study was to compare these receptors between living PD patients and healthy subjects. METHODS: Nicotinic acetylcholine receptors were imaged in 10 nondemented Parkinson's disease patients and 15 age-matched healthy subjects using a single-photon emission computed tomography ligand [(123)I]5-iodo-3-[2(S)-2-azetidinylmethoxy]pyridine. Using an arterial input function, we measured the total distribution volume (V; specific plus nondisplaceable), as well as the delivery (K(1)). RESULTS: Parkinson's disease showed a widespread significant decrease (approximately 10%) of V in both cortical and subcortical regions without a significant change in K(1). INTERPRETATION: These results indicate the importance of extending the study to demented patients.

Aged↗

Use of a compact pixellated gamma camera for small animal pinhole SPECT imaging.

OBJECTIVES: Pinhole SPECT which permits in vivo high resolution 3D imaging of physiological functions in small animals facilitates objective assessment of pharmaceutical development and regenerative therapy in pre-clinical trials. For handiness and mobility, the miniature size of the SPECT system is useful. We developed a small animal SPECT system based on a compact high-resolution gamma camera fitted to a pinhole collimator and an object-rotating unit. This study was aimed at evaluating the basic performance of the detection system and the feasibility of small animal SPECT imaging. METHODS: The gamma camera consists of a 22 x 22 pixellated scintillator array of 1.8 mm x 1.8 mm x 5 mm NaI(Tl crystals with 0.2-mm gap between the crystals coupled to a 2" flat panel position-sensitive photomultiplier tube (Hamamatsu H8500) with 64 channels. The active imaging region of the camera was 43.8 mm x 43.8 mm. Data acquisition is controlled by a personal computer (Microsoft Windows) through the camera controller. Projection data over 360 degrees for SPECT images are obtained by synchronizing with the rotating unit. The knife-edge pinhole collimators made of tungsten are attached on the camera and have 0.5-mm and 1.0-mm apertures. The basic performance of the detection system was evaluated with 99mTc and 201Tl solutions. Energy resolution, system spatial resolution and linearity of count rate were measured. Rat myocardial perfusion SPECT scans were sequentially performed following intravenous injection of 201TlCl. Projection data were reconstructed using a previously validated pinhole 3D-OSEM method. RESULTS: The energy resolution at 140 keV was 14.8% using a point source. The system spatial resolutions were 2.8-mm FWHM and 2.5-mm FWHM for 99mTc and 201Tl line sources, respectively, at 30-mm source distance (magnification factor of 1.3) using a 1.0-mm pinhole. The linearity between the activity and count rate was good up to 10 kcps. In a rat study, the left ventricular walls were clearly visible in all scans. CONCLUSIONS: We developed a compact SPECT system using compact gamma camera for small animals and evaluated basic physical performances. The present system may be of use for quantitation of biological functions such as myocardial blood flow in small animals.

Animals↗

Performance of list mode data acquisition with ECAT EXACT HR and ECAT EXACT HR+ positron emission scanners.

Recently, list mode (event-by-event) data acquisition with positron emission tomography (PET) has been widely noticed because list mode acquisition is superior to conventional frame mode data acquisition in terms of (1) higher efficiency of data storage, (2) higher temporal resolution, and (3) higher flexibility of data manipulation. The aim of this study is to investigate the performance of list mode data acquisition with ECAT EXACT HR and HR+ PET scanners (CTI PET Systems) and its feasibility in clinical applications. A cylindrical phantom (16 cm in diameter and length) filled with a 11C solution for the HR and a 15O solution for the HR+ was scanned several times by varying the radioactivity concentration with the list mode and frame mode acquisitions. The scans were also carried out with a septa (2D mode) and without a septa (3D mode) in order to evaluate the effect of the interplane septa on the quality of the list mode data. The acquired list mode data were sorted into a sinogram and reconstructed using a filtered back-projection algorithm. The count rate performance of the list mode data was comparable to that of the frame mode data. However, the list mode acquisition could not be performed when the radioactivity concentration in the field-of-view was high (exceeding 24 kBq/ml for the 3D mode) due to a lack of sufficient transfer speed for sending data from the memory to hard disk. In order to estimate the pixel noise in a reconstructed image, ten replicated data sets were generated from one list mode data. The reconstructed images with the 3D mode had a signal-to-noise ratio that was more than 60% better than that of the image with the 2D mode. The file size of the generated list mode data was also evaluated. In the case of ECAT EXACT HR+ with the 3D list mode, the list mode data with a generated file size of 2.31 Mbytes/ s were generated for 37 MBq injections. Our results suggest that careful attention must be paid to the protocol of the list mode data acquisition in order to obtain the highest performance of the PET scanner.

Algorithms↗

System design and development of a pinhole SPECT system for quantitative functional imaging of small animals.

Recently, small animal imaging by pinhole SPECT has been widely investigated by several researchers. We developed a pinhole SPECT system specially designed for small animal imaging. The system consists of a rotation unit for a small animal and a SPECT camera attached with a pinhole collimator. In order to acquire complete data of the projections, the system has two orbits with angles of 90 degrees and 45 degrees with respect to the object. In this system, the position of the SPECT camera is kept fixed, and the animal is rotated in order to avoid misalignment of the center of rotation (COR). We implemented a three dimensional OSEM algorithm for the reconstruction of data acquired by the system from both the orbitals. A point source experiment revealed no significant COR misalignment using the proposed system. Experiments with a line phantom clearly indicated that our system succeeded in minimizing the misalignment of the COR. We performed a study with a rat and 99mTc-HMDP, an agent for bone scan, and demonstrated a dramatic improvement in the spatial resolution and uniformity achieved by our system in comparison with the conventional Feldkamp algorithm with one set of orbital data.

Animals↗

Comparison of multi-ray and point-spread function based resolution recovery methods in pinhole SPECT reconstruction.

BACKGROUND AND OBJECTIVES: Statistical reconstruction methods allow resolution recovery in tomographic reconstruction. Even though resolution recovery has the potential to improve overall image quality, pinhole SPECT images are still often reconstructed using simplified models of the acquisition geometry in order to reduce reconstruction time. This paper investigates the benefits of two resolution recovery methods, multi-ray and point-spread function based, in pinhole SPECT by comparing them to uncorrected reconstruction. METHODS: Resolution recovery was incorporated into ordered subsets expectation maximization reconstruction algorithm. The first of the correction methods used a simple but very fast multiple projection ray approach, whereas the second, much slower, method modelled the acquisition geometry more accurately using the analytical point-spread function of the pinhole collimator. Line source, Jaszczak and contrast phantom studies were performed and used for comparison. RESULTS: Resolution recovery improved resolution, contrast and visual quality of the images when compared to reconstructions without it. The method based on the point-spread function performed slightly better, but was almost 50 times slower than the much simpler multi-ray approach. CONCLUSION: The multiple projection ray approach is a promising method for very fast and easy resolution recovery in pinhole SPECT. It has a profound effect on image quality and can markedly improve the resolution-sensitivity trade-off.

Algorithms↗

The association between the Val158Met polymorphism of the catechol-O-methyl transferase gene and morphological abnormalities of the brain in chronic schizophrenia.

The catechol-O-methyl transferase (COMT) gene is considered to be a promising schizophrenia susceptibility gene. A common functional polymorphism (Val158Met) in the COMT gene affects dopamine regulation in the prefrontal cortex (PFC). Recent studies suggest that this polymorphism contributes to poor prefrontal functions, particularly working memory, in both normal individuals and patients with schizophrenia. However, possible morphological changes underlying such functional impairments remain to be clarified. The aim of this study was to examine whether the Val158Met polymorphism of the COMT gene has an impact on brain morphology in normal individuals and patients with schizophrenia. The Val158Met COMT genotype was obtained for 76 healthy controls and 47 schizophrenics. The diagnostic effects, the effects of COMT genotype and the genotype-diagnosis interaction on brain morphology were evaluated by using a voxel-by-voxel statistical analysis for high-resolution MRI, a tensor-based morphometry. Patients with schizophrenia demonstrated a significant reduction of volumes in the limbic and paralimbic systems, neocortical areas and the subcortical regions. Individuals homozygous for the Val-COMT allele demonstrated significant reduction of volumes in the left anterior cingulate cortex (ACC) and the right middle temporal gyrus (MTG) compared to Met-COMT carriers. Significant genotype-diagnosis interaction effects on brain morphology were noted in the left ACC, the left parahippocampal gyrus and the left amygdala-uncus. No significant genotype effects or genotype-diagnosis interaction effects on morphology in the dorsolateral PFC (DLPFC) were found. In the control group, no significant genotype effects on brain morphology were found. Schizophrenics homozygous for the Val-COMT showed a significant reduction of volumes in the bilateral ACC, left amygdala-uncus, right MTG and left thalamus compared to Met-COMT schizophrenics. Our findings suggest that the Val158Met polymorphism of the COMT gene might contribute to morphological abnormalities in schizophrenia.

Adult↗

Development of a practical image-based scatter correction method for brain perfusion SPECT: comparison with the TEW method.

PURPOSE: An image-based scatter correction (IBSC) method was developed to convert scatter-uncorrected into scatter-corrected SPECT images. The purpose of this study was to validate this method by means of phantom simulations and human studies with 99mTc-labeled tracers, based on comparison with the conventional triple energy window (TEW) method. METHODS: The IBSC method corrects scatter on the reconstructed image I(mub)AC with Chang's attenuation correction factor. The scatter component image is estimated by convolving I(mub)AC with a scatter function followed by multiplication with an image-based scatter fraction function. The IBSC method was evaluated with Monte Carlo simulations and 99mTc-ethyl cysteinate dimer SPECT human brain perfusion studies obtained from five volunteers. The image counts and contrast of the scatter-corrected images obtained by the IBSC and TEW methods were compared. RESULTS: Using data obtained from the simulations, the image counts and contrast of the scatter-corrected images obtained by the IBSC and TEW methods were found to be nearly identical for both gray and white matter. In human brain images, no significant differences in image contrast were observed between the IBSC and TEW methods. CONCLUSION: The IBSC method is a simple scatter correction technique feasible for use in clinical routine.

Algorithms↗

Understanding of cerebral energy metabolism by dynamic living brain slice imaging system with [18F]FDG.

Recently, lactate has been receiving great attention as an energy substrate in the brain. In this study, the role of lactate was evaluated by "bioradiography" system with 2-deoxy-2-[(18)F]fluoro-d-glucose ([(18)F]FDG), which is a positron emitting radiotracer for glucose uptake quantification. "Bioradiography" is the dynamic living tissue slice imaging system for positron-emitter labeled compounds. We investigated the brain energy metabolism under resting state and neural activated conditions induced by KCl addition. The monocarboxylate transporter inhibitor, alpha-cyano-4-hydroxycinnamate (4-CIN), had no effect on [(18)F]FDG uptake rate in rat brain slices before KCl addition. On the other hand, addition of 4-CIN induced larger [(18)F]FDG uptake rates under the activated condition in comparison with the control condition. Because neurons cannot utilize lactate under the 4-CIN loaded conditions, this indicates that activated neurons consume lactate as an energy substrate. The lactate concentration in the incubation medium was increased with KCl treatment in both groups and the extent was slightly greater in 4-CIN group. These results suggested that: (1) the brain mainly uses glucose, not lactate, as an energy substrate in resting state; (2) when neuron is stimulated, excess amounts of lactate might be produced in astrocytes and the lactate is mobilized as an energy substrate.

Animals↗

Rapid quantitative measurement of CMRO(2) and CBF by dual administration of (15)O-labeled oxygen and water during a single PET scan-a validation study and error analysis in anesthetized monkeys.

Cerebral blood flow (CBF) and rate of oxygen metabolism (CMRO(2)) may be quantified using positron emission tomography (PET) with (15)O-tracers, but the conventional three-step technique requires a relatively long study period, attributed to the need for separate acquisition for each of (15)O(2), H(2)(15)O, and C(15)O tracers, which makes the multiple measurements at different physiologic conditions difficult. In this study, we present a novel, faster technique that provides a pixel-by-pixel calculation of CBF and CMRO(2) from a single PET acquisition with a sequential administration of (15)O(2) and H(2)(15)O. Experiments were performed on six anesthetized monkeys to validate this technique. The global CBF, oxygen extraction fraction (OEF), and CMRO(2) obtained by the present technique at rest were not significantly different from those obtained with three-step method. The global OEF (gOEF) also agreed with that determined by simultaneous arterio-sinus blood sampling (gOEF(A-V)) for a physiologically wide range when changing the arterial PaCO(2) (gOEF=1.03gOEF(A-V)+0.01, P<0.001). The regional values, as well as the image quality were identical between the present technique and three-step method for CBF, OEF, and CMRO(2). In addition, a simulation study showed that error sensitivity of the present technique to delay or dispersion of the input function, and the error in the partition coefficient was equivalent to that observed for three-step method. Error sensitivity to cerebral blood volume (CBV) was also identical to that in the three-step and reasonably small, suggesting that a single CBV assessment is sufficient for repeated measures of CBF/CMRO(2). These results show that this fast technique has an ability for accurate assessment of CBF/CMRO(2) and also allows multiple assessment at different physiologic conditions.

Algorithms↗

Parametric imaging of myocardial blood flow with 15O-water and PET using the basis function method.

UNLABELLED: Regional myocardial blood flow (MBF) can be measured with 15O-water and PET using the 1-tissue-compartment model with perfusable tissue fraction, which provides an MBF value that is free from the partial-volume effect. Studies with 15O-water have several advantages, such as the ability to repeat a scan. However, because of the short scanning time and the small distribution volume of 15O-water in the myocardium, the image quality of 15O-water is limited, impeding the computation of MBF and perfusable tissue fraction at the voxel level. We implemented the basis function method for generating parametric images of MBF, perfusable tissue fraction, and arterial blood volume (Va) with 15O-water and PET. The basis function method linearizes the solution of the 1-tissue-compartment model, which results in a computationally much faster method than the conventional nonlinear least-squares fitting method in estimating the parameters. METHODS: To validate the basis function method, we performed a series of PET studies on miniature pigs (n = 7). After acquisition of the transmission scan for attenuation correction and the 15O-CO scan for obtaining the blood-pool image, repeated PET scans with 15O-water were obtained with varying doses of adenosine or CGS-21680 (selective adenosine A(2a) receptor agonist). MBF, perfusable tissue fraction, and Va values of the myocardial region for each scan were computed using the basis function method and the nonlinear least-squares method, and the parameters estimated by the 2 methods were compared. RESULTS: MBF images generated by the basis function method demonstrated an increase in blood flow after administration of adenosine or CGS-21680. The MBF values estimated by the basis function method and by the nonlinear least-squares method correlated strongly. CONCLUSION: The basis function method produces parametric images of MBF, perfusable tissue fraction, and Va with 15O-water and PET. These images will be useful in detecting regional myocardial perfusion abnormalities.

Algorithms↗

Development of a hyperpolarized 129Xe system on 3T for the rat lungs.

MRI (magnetic resonance imaging) with 129Xe has gained much attention as a diagnostic methodology because of its affinity for lipids and possible polarization. The quantitative estimation of net detectability and stability of hyperpolarized 129Xe in the dissolved phase in vivo is valuable to the development of clinical applications. The goal of this study was to develop a stable hyperpolarized 129Xe experimental 3T system to statistically analyze the dissolved-phase 129Xe signal in the rat lungs. The polarization of 129Xe with buffer gases at the optical pumping cell was measured under adiabatic fast passage against the temperature of an oven and laser absorption at the cell. The gases were insufflated into the lungs of Sprague-Dawley rats (n = 15, 400-550 g) through an endotracheal tube under spontaneous respiration. Frequency-selective spectroscopy was performed for the gas phase and dissolved phase. We analyzed the 129Xe signal in the dissolved phase to measure the chemical shift, T2*, delay and its ratio in a rat lungs on 3T. The polarizer was able to produce polarized gas (1.1+/-0.47%, 120 cm3) hundreds of times with the laser absorption ratio (25%) kept constant at the cell. The optimal buffer gas ratio of 25-50% rendered the maximum signal in the dissolved phase. Two dominant peaks of 211.8+/-0.9 and 201.1+/-0.6 ppm were observed with a delay of 0.4+/-0.9 and 0.9+/-1.0 s from the gas phase spectra. The ratios of their average signal to that of the gas phase were 5.6+/-5.2% and 4.4+/-4.7%, respectively. The T2* of the air space in the lungs was 2.5+/-0.5 ms, which was 3.8 times shorter than that in a syringe. We developed a hyperpolarized 129Xe experimental system using a 3T MRI scanner that yields sufficient volume and polarization and quantitatively analyzed the dissolved-phase 129Xe signal in the rat lungs.

Administration, Inhalation↗

A new reconstruction strategy for image improvement in pinhole SPECT.

Pinhole single-photon emission computed tomography (SPECT) is able to provide information on the biodistribution of several radioligands in small laboratory animals, but has limitations associated with non-uniform spatial resolution or axial blurring. We have hypothesised that this blurring is due to incompleteness of the projection data acquired by a single circular pinhole orbit, and have evaluated a new strategy for accurate image reconstruction with better spatial resolution uniformity. A pinhole SPECT system using two circular orbits and a dedicated three-dimensional ordered subsets expectation maximisation (3D-OSEM) reconstruction method were developed. In this system, not the camera but the object rotates, and the two orbits are at 90 degrees and 45 degrees relative to the object's axis. This system satisfies Tuy's condition, and is thus able to provide complete data for 3D pinhole SPECT reconstruction within the whole field of view (FOV). To evaluate this system, a series of experiments was carried out using a multiple-disk phantom filled with 99mTc solution. The feasibility of the proposed method for small animal imaging was tested with a mouse bone study using 99mTc-hydroxymethylene diphosphonate. Feldkamp's filtered back-projection (FBP) method and the 3D-OSEM method were applied to these data sets, and the visual and statistical properties were examined. Axial blurring, which was still visible at the edge of the FOV even after applying the conventional 3D-OSEM instead of FBP for single-orbit data, was not visible after application of 3D-OSEM using two-orbit data. 3D-OSEM using two-orbit data dramatically reduced the resolution non-uniformity and statistical noise, and also demonstrated considerably better image quality in the mouse scan. This system may be of use in quantitative assessment of bio-physiological functions in small animals.

Algorithms↗

Endogenous dopamine release induced by repetitive transcranial magnetic stimulation over the primary motor cortex: an [11C]raclopride positron emission tomography study in anesthetized macaque monkeys.

BACKGROUND: Repetitive transcranial magnetic stimulation (rTMS) has been used as a treatment for neuropsychiatric disorders such as depression and Parkinson's disease (PD). Despite the growing interest in therapeutic application of rTMS, precise mechanisms of its action remain unknown. With respect to PD, activation of the mesostriatal dopaminergic pathway is likely to be a candidate mechanism underlying the therapeutic effects; however, modulating effects of rTMS over the primary motor cortex (M1) on the dopaminergic system have not been studied. METHODS: We used [11C]raclopride positron emission tomography to measure changes of extracellular dopamine concentration after 5Hz rTMS over the M1 in eight anesthetized monkeys. RESULTS: rTMS over the right M1 induced a reduction of [11C]raclopride binding potential (BP) in the bilateral ventral striatum, including the nucleus accumbens, and a significant increase of BP in the right putamen; no significant BP reduction was found in the dorsal striatum. These data indicate that rTMS over the motor cortex induces a release of endogenous dopamine in the ventral striatum. CONCLUSIONS: Our results suggest that therapeutic mechanisms of rTMS may be explained in part by an activation of the mesolimbic dopaminergic pathway, which plays critical roles in rewards, reinforcement, and incentive motivation.

Animals↗

Effect of scatter correction on the compartmental measurement of striatal and extrastriatal dopamine D2 receptors using [123I]epidepride SPET.

Prior studies with anthropomorphic phantoms and single, static in vivo brain images have demonstrated that scatter correction significantly improves the accuracy of regional quantitation of single-photon emission tomography (SPET) brain images. Since the regional distribution of activity changes following a bolus injection of a typical neuroreceptor ligand, we examined the effect of scatter correction on the compartmental modeling of serial dynamic images of striatal and extrastriatal dopamine D(2) receptors using [(123)I]epidepride. Eight healthy human subjects [age 30+/-8 (range 22-46) years] participated in a study with a bolus injection of 373+/-12 (354-389) MBq [(123)I]epidepride and data acquisition over a period of 14 h. A transmission scan was obtained in each study for attenuation and scatter correction. Distribution volumes were calculated by means of compartmental nonlinear least-squares analysis using metabolite-corrected arterial input function and brain data processed with scatter correction using narrow-beam geometry micro (SC) and without scatter correction using broad-beam micro (NoSC). Effects of SC were markedly different among brain regions. SC increased activities in the putamen and thalamus after 1-1.5 h while it decreased activity during the entire experiment in the temporal cortex and cerebellum. Compared with NoSC, SC significantly increased specific distribution volume in the putamen (58%, P=0.0001) and thalamus (23%, P=0.0297). Compared with NoSC, SC made regional distribution of the specific distribution volume closer to that of [(18)F]fallypride. It is concluded that SC is required for accurate quantification of distribution volumes of receptor ligands in SPET studies.

Adult↗

Long-term effect of motor cortical repetitive transcranial magnetic stimulation [correction].

Repetitive transcranial magnetic stimulation (rTMS) recently has been assessed as a noninvasive treatment modality for movement and psychiatric disorders, whereas the mechanism underlying the therapeutic effects is not fully understood. Studies in rodents showed lasting functional changes in some selected regions, such as limbic-associated structures, but unfocused brain stimulation did not clarify the regional effects. To address the topographical and temporal profiles of the effects on glucose metabolism in primate brain, we performed rTMS and repeated (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) before, during, and up to 16 days after rTMS in anesthetized cynomologous monkeys. We delivered a total of 2,000 pulses of 5 Hz-rTMS over the right precentral gyrus using a small-sized eight-figured coil that induced a localized electrical field. Voxel-based analysis in a standard space of the macaque brain showed statistically robust changes in FDG uptake: a decrease in the motor/premotor cortices and an increase in the limbic-associated areas involving the anterior/posterior cingulate, and orbitofrontal cortices. Interestingly, these uptake changes continued for at least 8 days and the magnitude of the lasting effects in the limbic-related areas was negatively correlated across subjects with those in the motor/premotor cortices. The results demonstrate that motor rTMS has a long-term lasting effect on motor-related regions and distant limbic-related areas via functional connections.

Animals↗