PubMed Health⌕ Search

Biomedical subjects

Hideo Tashiro

Publications and source records attributed to Hideo Tashiro.

9 recordsLinked to original sources

Intravascular Raman spectroscopic catheter for molecular diagnosis of atherosclerotic coronary disease.

An intravascular catheter for Raman spectroscopic detection and analysis of coronary atherosclerotic disease has been developed. The catheter, having an outer diameter of 2 mm, consisted of a side-view-type micro-Raman probe, an imaging fiber bundle, a working channel (injection drain), and a balloon. By inflating the balloon, the probe was brought close to the inner wall of a modeled blood flow system and detected a phantom target buried in the wall. Results obtained demonstrate the possibility of using the spectroscopic catheter for molecular diagnosis of coronary lesions.

Animals↗

Automatic continuous scanning and random-access switching of mid-infrared waves generated by difference-frequency mixing.

We report the rapid tuning of mid-infrared waves beyond 5 microm emitted in difference-frequency mixing with an electronically tuned dual-wavelength Ti:Al2O3 laser used as a pumping source. Simultaneous rapid tuning of the dual wavelengths, which satisfy phase matching in AgGaS2, allows rapid random access switching and continuous tuning of mid-infrared wavelengths. In random-access switching, the mid-infrared wavelength is tuned every pulse shot at a repetition rate of 1 kHz. Mid-infrared wavelengths continuously tuned from 5.2 to 7.2 microm, from 7.0 to 9.1 microm, and from 8.9 to 12.0 microm are achieved at phase-matched angles of 55 degrees, 50 degrees, and 45 degrees, respectively.

Journal Article↗

Fluorescence-suppressed Raman technique for quantitative analysis of protein solution using a micro-Raman probe, the shifted excitation method, and partial least squares regression analysis.

A practical Raman analyzing technique with suppression of the strong fluorescent background in order to obtain quantitative information is proposed in the present study. The technique is based on the shifted excitation method and partial least squares regression (PLSR) analysis. The Raman system consists of a single Raman spectrometer, a background-free electrically tunable Ti:Sapphire laser (BF-ETL), and a micro-Raman probe (MRP). The system allows one to obtain reliable shifted excitation Raman spectra with a simple operation. The PLSR analysis successfully provides quantitative information from the obtained spectra with the suppression of random noise including photon shot noise. The present study demonstrates that the technique is effective for extracting quantitative information concealed behind a fluorescent background that is more than 200 times stronger than the Raman signal.

Animals↗

Flexural rigidity of individual microtubules measured by a buckling force with optical traps.

We used direct buckling force measurements with optical traps to determine the flexural rigidity of individual microtubules bound to polystyrene beads. To optimize the accuracy of the measurement, we used two optical traps and antibody-coated beads to manipulate each microtubule. We then applied a new analytical model assuming nonaxial buckling. Paclitaxel-stabilized microtubules were polymerized from purified tubulin, and the average microtubule rigidity was calculated as 2.0 x 10(-24) Nm2 using this novel microtubule buckling system. This value was not dependent on microtubule length. We also measured the rigidity of paclitaxel-free microtubules, and obtained the value of 7.9 x 10(-24) Nm2, which is nearly four times that measured for paclitaxel-stabilized microtubules.

Animals↗

Raman probe using a single hollow waveguide.

A simple Raman probe was realized using a single flexible hollow waveguide (HW). A HW coated with a silver film, which had reasonable transmission and little optical background noise, was used as a bidirectional transmission fiber for both the excitation and collection of Raman scattered light. The HW itself generated no Raman scattering or fluorescence noise during transmission. A complex filtering system at the end of the waveguide was thus unnecessary. In addition, the measured Raman spectra showed better signal-to-noise ratios than a conventional Raman fiber probe. The HW's suitability as a Raman fiber probe was also demonstrated.

Equipment Design↗

Micro-optical fiber probe for use in an intravascular Raman endoscope.

We believe that we have developed the narrowest optical-fiber Raman probe ever reported, 600 microm in total diameter, that can be inserted into coronary arteries. The selection of suitable optical fibers, filters, and a processing method is discussed. Custom-made filters attached to the front end of a probe eliminate the background Raman signals of the optical fiber itself. The experimental evaluation of various optical fibers is carried out for the selection of suitable fibers. Measurement of the Raman spectra of an atherosclerotic lesion of a rabbit artery in vitro demonstrates the excellent performance of the micro-Raman probe.

Angioscopes↗

Monitoring synaptogenesis in the developing mouse cerebellum with an original oligonucleotide microarray.

Use of DNA microarrays in neuroscience have been limited to rough screening purposes, mainly because the reliability and sensitivity of available arrays are not high enough. Because only a few hundred to one thousand genes are usually found to change expression levels in most experiments, we attempted to develop a more quantitative array by the following strategies: 1) limit the genes to those relevant to the experimental system, 2) design oligonucleotide probes of specified molecular properties so that more stringent hybridization conditions can be employed, 3) place six spots per probe on one slide and use multiple normalization genes, and 4) use a new type of gold-coated slide with higher S/N ratio. Genes involved in the construction and functioning of the synapse were selected from the literature as well as experimentally by comparing cerebella from hypothyroid and control mice at postnatal day 15 (P15). Although the number of genes covered was not yet large (172 genes), the custom array "Synaptoarray" thus constructed was capable of detecting +/-20% difference in gene expression ratios. Analysis of the postnatal development of the mouse cerebellum by using Synaptoarray demonstrated a general expression pattern with a peak at P7, followed by a decline at P15 and a partial recovery after P21. P10 clearly marked the end of the initial growth stage and a major transcriptional turning point in this system. This result suggests that such a custom array should be useful in monitoring perturbations to the normal developmental program.

Animals↗

Excitation wavelength dependent surface-enhanced Raman spectra of a dipping film of azobenzene-containing long-chain fatty acid on a silver mirror.

Surface-enhanced Raman scattering (SERS) of dipping films of azobenzene-containing long-chain fatty acids, nAmH (n=8, 12, m=3, 5), on silver mirrors measured with a wide range of excitation wavelengths in the 457.9-1064 nm region is reported. The obtained Raman spectra show great SERS effect even with the 1064 nm excitation, and the excitation with 457.9, 476.5, and 488.0 nm gives surface-enhanced resonance Raman scattering (SERRS) due to the resonance effect of the symmetry-forbidden n-pi* transition of the azo group. Of particular note in the present study is that the SERS spectra with the excitation in the 532-1064 nm region yield Raman bands whose frequencies are almost identical to those bands in Raman spectra of nAmH in solid state while the SERRS spectra with the excitation in the 457.9-514.5 nm region show not only a set of bands which correspond to those of nAmH in the solid state but also a set of bands whose frequencies show a significant shift from those of the bands of nAmH in the solid state. These observations lead us to conclude that there are two kinds of molecular aggregates in the dipping films of azobenzene-containing long-chain fatty acid in which azobenzene moieties are condensed to form small bundles.

Azo Compounds↗