PubMed Health⌕ Search

Biomedical subjects

Hidetoshi Katori

Publications and source records attributed to Hidetoshi Katori.

6 recordsLinked to original sources

An optical lattice clock.

The precision measurement of time and frequency is a prerequisite not only for fundamental science but also for technologies that support broadband communication networks and navigation with global positioning systems (GPS). The SI second is currently realized by the microwave transition of Cs atoms with a fractional uncertainty of 10(-15) (ref. 1). Thanks to the optical frequency comb technique, which established a coherent link between optical and radio frequencies, optical clocks have attracted increasing interest as regards future atomic clocks with superior precision. To date, single trapped ions and ultracold neutral atoms in free fall have shown record high performance that is approaching that of the best Cs fountain clocks. Here we report a different approach, in which atoms trapped in an optical lattice serve as quantum references. The 'optical lattice clock' demonstrates a linewidth one order of magnitude narrower than that observed for neutral-atom optical clocks, and its stability is better than that of single-ion clocks. The transition frequency for the Sr lattice clock is 429,228,004,229,952(15) Hz, as determined by an optical frequency comb referenced to the SI second.

Journal Article↗

Lifetime measurement of the 3P2 metastable state of strontium atoms.

We have measured the lifetime of the 5s5p 3P2 metastable state of strontium atoms by magneto-optically trapping the decayed atoms to the ground state, which allowed sensitive detection of the rare decay events. We found that the blackbody radiation-induced decay was the dominant decay channel for the state at T=300 K. The lifetime was determined to be 520(+310)(-140) s in the limit of zero temperature, arguably the longest lifetime ever determined in a laboratory environment.

Journal Article↗

Spectroscopy of the 1S0-3P0 clock transition of 87Sr in an optical lattice.

We report on the spectroscopy of the 5s(2) 1S0(F=9/2)-->5s5p 3P0(F=9/2) clock transition of 87Sr atoms (natural linewidth of 1 mHz) trapped in a one-dimensional optical lattice. Recoilless transitions with a linewidth of 0.7 kHz as well as the vibrational structure of the lattice potential were observed. By investigating the wavelength dependence of the carrier linewidth, we determined the magic wavelength, where the light shift in the clock transition vanishes, to be 813.5+/-0.9 nm.

Journal Article↗

Ultrastable optical clock with neutral atoms in an engineered light shift trap.

An ultrastable optical clock based on neutral atoms trapped in an optical lattice is proposed. Complete control over the light shift is achieved by employing the 5s(2) 1S0-->5s5p 3P0 transition of 87Sr atoms as a "clock transition." Calculations of ac multipole polarizabilities and dipole hyperpolarizabilities for the clock transition indicate that the contribution of the higher-order light shifts can be reduced to less than 1 mHz, allowing for a projected accuracy of better than 10(-17).

Journal Article↗

Recoil-free spectroscopy of neutral Sr atoms in the Lamb-Dicke regime.

Recoil-free as well as Doppler-free spectroscopy was demonstrated on the 1S0-3P1 transition of Sr atoms confined in a one-dimensional optical lattice. By investigating the wavelength and polarization dependence of the ac Stark shift acting on the 1S0 and 3P1(m(J)=0) states, we determined the wavelength where the Stark shifts for both states coincide. This Stark-free optical lattice, allowing the purturbation-free spectroscopy of trapped atoms, may keep neutral-atom based optical standards competitive with single-ion standards.

Journal Article↗

Recoil-limited laser cooling of 87Sr atoms near the Fermi temperature.

A dynamic magneto-optical trap, which relies on the rapid randomization of population in Zeeman substates, has been demonstrated for fermionic strontium atoms on the 1S0-3P1 intercombination transition. The obtained sample, 1x10(6) atoms at a temperature of 2 microK in the trap, was further Doppler cooled and polarized in a far-off resonant optical lattice to achieve 2 times the Fermi temperature.

Journal Article↗