Preclinical development of SMA artificial anal sphincters.

This article presents some progress in the development for preclinical trials of an artificial anal sphincter using shape memory alloys. The novel device has been proposed and developed by the author's group at Tohoku University. It has two dominant features different from other systems, which are either clinically available or still under development. One is that a solid driving element, a combination of shape memory alloy (SMA) ribbons and silicone elastomer sheets with a layered structure, is adopted for the opening and closing functions of the artificial sphincter. The other is a sandwich mechanism for the closing of bowel to reduce the risk of buckling induced ischemia which has been reported in hydraulically driven artificial sphincters with a radial squeezing mechanism. The device has fewer parts inside the body and therefore be implanted more easily. A new design eliminating the risk of heat burns enables long-term implantation and brings the device closer to practical use. Functionality and safety of the device have been proved in three-month animal experiments.

Alloys↗

Development of the pulsation device for rotary blood pumps.

A rotary blood pump (RP) is desirable as a small ventricular assist device (VAD). However, an RP is nonpulsatile. We tried to develop a device that attaches a pulse to the RP. We also tried to develop a pulse-generating equipment that was not air-pressure driven. The ball screw motor was considered a candidate. The application of a small-sized shape memory alloy was also attempted. An electrohydraulic system was adopted, and actuator power was connected to the diaphragm. The diaphragm was placed on the outer side of the ventricle. Most RPs that have been developed all over the world drain blood from the ventricle. The wave of a pulse should be generated if a pulse is added by the drawn part. The output assistance from the outer side of the ventricle was attempted in animal experiments, and the device operated effectively. This device can be used during implantable operation of RP. This may serve as an effective device in patients experiencing problems in peripheral circulation and in the function of internal organs.

Animals↗

Addition of rhythm to non-pulsatile circulation.

The development of a rotary blood pump (RP) is desirable as it can be used as a small ventricular assistance device (VAD). However, a RP does not generate any pulse. It may be physiologically better for the patient if the RP could generate a pulse. We have attempted to develop a device that produces a pulse in the RP. Intra-aortic balloon pumping (IABP) is effective in producing a pulse. However, the IABP cannot be implanted inside the body. Therefore, an attempt was made to develop pulse-generating equipment that was not driven by air pressure. The ball screw motor was considered as a possible candidate. In the future, we plan to apply small shape memory alloys. An electrohydraulic system was adopted, and actuator power output was connected to the diaphragm. The diaphragm was placed outside the ventricle. Most RPs developed throughout the world drain blood from the ventricle. The pulse wave should be generated if a pulse is added by the part from which blood is being drawn. In this study, animal experiments were conducted and the output assistance was tested from outside the ventricle. The device operated effectively in the animal experiment. The RP can easily be equipped with this device at the time of performing the implant operation. For a patient with problems of peripheral circulation and the internal organ function, it may prove to be an effective device.

Animal Experimentation↗

Development of an implantable undulation type ventricular assist device for control of organ circulation.

It is well known that a rotary blood pump (RP) is effective as a small ventricular assist device (VAD). It might be still more effective if pulsation was available. The undulation pump (UP), which is a type of small RP, can also produce pulsation. In Japan, a development project for an implantable type UP ventricular assist device (UPVAD) is now advanced. Six universities and some companies together have been in charge of the development project for 5 years. In this study, the influence which the UP under development has on circulation in internal organs was investigated. Goats with the same weight as an average Asian person were used for the experiment. The left chest cavity was opened after resection of the fourth rib and the heart was approached. A cannula was inserted in the left ventricle from the apex. An outflow cannula was inserted into the left descending aorta. Heart muscle was excised using a newly developed puncher. The UPVAD was implanted using a left-heart bypass system. The myocardial blood flow, carotid arterial blood flow, and the kidney blood flow were recorded together with an electrocardiogram, blood pressure, and the flow rate. In these animal experiments, the blood circulation dynamic state was stabilized and sufficient support of the left heart was observed. Myocardial blood flow, carotid arterial flow, and a kidney blood flow increase resulting from UPVAD support was observed. Often the problem of multiple organ failure is important at the time of clinical application of a ventricular assist device. Assisting circulation to internal organs is important for prevention of multiple organ failure. It was concluded that the UPVAD might be useful for prevention of multiple organ failure.

Animals↗

Component engineering for an implantable system.

Component engineering is important for the development of implantable-type rotary blood pumps (RP). The authors are conducting elementary development of an implantable artificial heart. A sensor system detects information in the living body. An automatic control system performs the drive control. Energy is provided by a transcutaneous energy transmission system (TETS). Various artificial hearts are being created. Miniaturization resulting from an increase in operating frequency is planned. A vibrating flow pump (VFP) has a reduced size of pumping chamber because of the high-speed reciprocating movement. Undulation pump ventricular assist devices (UPVAD) are small, lightweight rotary pumps. VFPs are useful in the medical treatment of multiple organ failure (MOF). UPVADs are planned to be permanent-use RPs. The purposes of these two artificial hearts differ, although they have a common component. The authors are developing TETS by using amorphous fibers, making efficient power transmission possible. Control information input from a micro or nano sensor is realized. A control algorithm has been developed and baroreflex control has been successful. Artificial heart development, fully exploiting component engineering, continues.

Animals↗

Artificial myocardium with an artificial baroreflex system using nano technology.

Where is the place which should be helped in a patient with congestive heart failure? The answer may be contraction of the heart. At Tohoku University, development research of "the artificial myocardium" has been conducted, using a ball screw type electromagnetic motor. Furthermore, super-miniaturization is being attempted at present. Thus, a system with shape memory alloy is being developed. The cooling speed problem was solved by the application of the Peltier element. A drive at a speed equal to that of a heartbeat was realized by the application of this system. At present, a ventricular assist device is used for patients waiting for a heart transplant in Japan. An air driven type system disturbs a patient's QOL remarkably because it is connected to the drive device. With our concept, energy is provided by using the electromagnetic force from outside of the body by the use of transcutaneous energy transmission system. Magnetic shielding by amorphous fibers was used at Tohoku University to improve the total efficiency. A natural heart can alter the cardiac output corresponding to the demand. Artificial internal organs must participate in the system of the living body, too. Tohoku University has developed a resistance based artificial heart control algorithm, which simulated a baroreflex system to cope with every demand. Nano level sensing equipment is now under development at Tohoku University. At present, development is being conducted aiming at an "intelligent artificial myocardium".

Baroreflex↗

Recent progress in artificial organ research at Tohoku University.

Tohoku University has developed various artificial organs over the last 30 years. Pneumatic driven ventricular assist devices with a silicone ball valve have been designed by the flow visualization method, and clinical trials have been performed in Tohoku University Hospital. On the basis of these developments, a pneumatic driven total artificial heart has been developed and an animal experimental evaluation was conducted. The development of artificial organs in Tohoku University has now progressed to the totally implantable type using the transcutaneous energy transmission system with amorphous fibers for magnetic shielding. Examples of implantable systems include a vibrating flow pump for ventricular assist device, an artificial myocardium by the use of shape memory alloy with Peltier elements, and an artificial sphincter for patients with a stoma. An automatic control system for artificial organs had been developed for the ventricular assist devices including a rotary blood pump to avoid suction and to maintain left and right heart balance. Based upon the technology of automatic control algorithm, a new diagnostic tool for evaluating autonomic nerve function has been developed as a branch of artificial organ research and this new machine has been tested in Tohoku University Hospital. Tohoku University is following a variety of approaches aimed at innovation in artificial organs and medical engineering fields.

Academic Medical Centers↗

Functional evaluation of an artificial anal sphincter using shape memory alloys.

This article describes an implantable artificial anal sphincter using shape memory alloys and its in vivo assessment in porcine models. The new design was developed as a low invasive prosthesis with a simple structure to solve the problem of severe fecal incontinence in patients with hypoplastic sphincters or without anal sphincters and especially for ostomates. The artificial anal sphincter consists of two shape memory alloy (SMA) plates as the main functional parts to perform two basic functions when the SMA artificial sphincter is fitted around intestines (i.e., an occlusion at body temperature and an opening function on heating). Our previous assessments with short-term animal experiments revealed promising properties with the occlusion function of the device, although some complications, such as overpressure induced ischemia, heat burn, and infections, remained. This article addresses the concerns related to the practical use of the device, the power supplement to drive the actuator, and overheating protection of the device inside bodies. Results of chronic animal experiments of up to 4 weeks suggested great potential for the improved device.

Alloys↗