PubMed Health⌕ Search

Biomedical subjects

Hideyuki Takada

Publications and source records attributed to Hideyuki Takada.

6 recordsLinked to original sources

Ultralow-jitter passive timing stabilization of a mode-locked Er-doped fiber laser by injection of an optical pulse train.

The pulse timing of a mode-locked Er-doped fiber laser was stabilized to a reference pulse train from a Cr:forsterite mode-locked laser by all-optical passive synchronization scheme. The reference pulses were injected into a ring cavity of the fiber laser by using a 1.3-1.5 mum wavelength-division multiplexer. The spectral shift induced by cross-phase modulation between copropagating two-color pulses realizes self-synchronization due to intracavity group-delay dispersion. The rms integration of timing jitter between the fiber laser pulse and the reference pulse was 3.7 fs in a Fourier frequency range from 1 Hz to 100 kHz.

Journal Article↗

High-repetition-rate 12 fs pulse amplification by a Ti:sapphire regenerative amplifier system.

We demonstrate the direct generation of 12 fs pulses from a Ti:sapphire regenerative amplifier system at a 1 kHz repetition rate utilizing properly designed broadband components for chirped-pulse amplification. Optimized designs of a regenerative amplifier with a multilayer gain-narrowing compensator and an adaptive dispersion compensator with a spatial light modulator contribute to the shorter pulse amplification.

Journal Article↗

Long-term optical phase locking between femtosecond Ti:sapphire and Cr:forsterite lasers.

Long-term optical phase-coherent two-color femtosecond pulses were generated by use of passively timing-synchronized Ti:sapphire and Cr:forsterite lasers. The relative carrier-envelope phase relation was fixed by an active feedback loop. The accumulated phase noise from 10 mHz to 1 MHz of the locked beat note was 0.43 rad, showing tight phase locking. The optical frequency fluctuation between two femtosecond combs was submillihertz, with a 1 s averaged counter measurement over 3400 s, leading to a long-term femtosecond frequency-comb connection.

Journal Article↗

100-attosecond timing jitter between two-color mode-locked lasers by active-passive hybrid synchronization.

We have demonstrated a reduction of the timing jitter between passively synchronized Ti:sapphire and Cr:forsterite mode-locked lasers into a 100-attosecond (as) regime by suppressing slow fluctuations with the use of active slow-bandwidth extracavity feedback. This active-passive hybrid synchronization scheme permits the achievement of timing jitters of 98 +/- 18 as at a bandwidth of 100 kHz and of 126 +/- 20 as at a bandwidth of 1 MHz for as long as 100 s.

Journal Article↗

Broad-spectrum frequency comb generation and carrier-envelope offset frequency measurement by second-harmonic generation of a mode-locked fiber laser.

A frequency comb spanning more than one octave has been achieved by injecting the second-harmonic generation (780 nm) of a mode-locked fiber laser (1.56 microm) into a photonic crystal fiber. We propose and realize a novel interferometric scheme for observing the carrier-envelope offset frequency of the frequency comb. Frequency noise has been observed on the measured carrier-envelope offset frequency, which has been confirmed to be generated in the photonic crystal fiber by comparing the measured beat frequencies between cw lasers and frequency combs before and after the photonic crystal fiber. The mode-locked fiber laser is considered to be an important candidate for the light source used in realizing a compact optical frequency measurement system including applications in the telecommunication bands.

Journal Article↗

Optical phase locking among femtosecond subharmonic pulses.

We stabilized the relative carrier-envelope phase slip among the pump pulse and its subharmonic signal and idler pulses in a femtosecond optical parametric oscillator, resulting in long-term phasecoherence among the pulses. The stabilized beat signal corresponding to the relative carrier-envelope phase slip among subharmonic pulses had an accumulated phase error of 0.24 rad in the 1-mHz-1-MHz region. The fluctuation of the beat frequency measured by a 1-s-averaged counter was less than 1 mHz in a 1480-s measurement.

Journal Article↗