AmpliChip CYP450 GeneChip: a new gene chip that allows rapid and accurate CYP2D6 genotyping.

Methods for Cytochrome P450-2D6 (CYP2D6) genotyping are often time-consuming and laborious, which can restrict their use in pretherapeutic screening programs. Gene chip technology could overcome this problem. The aim of this study was to evaluate CYP2D6 genotyping by a new improved gene chip compared to a PCR-RFLP method. AmpliChip CYP450 GeneChip(R) (AmpliChip) is a microarray hybridization method for genotyping CYP2D6 and CYP2C19. One hundred fifty-nine DNA samples were genotyped both by AmpliChip as well as by PCR-RFLP and, where applicable, by a SNaPshot technique which detects single nucleotide polymorphisms based on the single base extension principle. In 152 of the 159 samples, CYP2D6 genotypes determined with the AmpliChip were in accordance with the results of PCR-RFLP. All seven discrepant samples had gene duplications and were subjected to SNaPshot analysis. SNaPshot results concurred with those of the AmpliChip for six out of seven samples. In the one divergent result, DNA sequencing confirmed that the AmpliChip had assigned the correct genotype. In conclusion, AmpliChip is a highly reliable method for CYP2D6 genotyping that allows the correct determination of all relevant CYP2D6 alleles in one single run. It therefore represents a very efficient and fast method, offering new perspectives for the application of pharmacogenetics in clinical medicine.

Cytochrome P-450 CYP2D6↗

Automated cerebrospinal fluid cytology: limitations and reasonable applications.

OBJECTIVE: To evaluate the precision and clinical applicability of the Bayer ADVIA 120 cytometer (Bayer Healthcare, Fernwald, Germany) for cerebrospinal fluid (CSF) cell count and differentiation. STUDY DESIGN: One hundred six analyses of CSF from 98 patients by the ADVIA 120 were compared with routine cell count and microscopic differentiation. Correlation coefficients were calculated. RESULTS: In general, the total cell counts of both methods correlated well. The best correlations were seen at higher cell counts, > or = 100 cells per microliter with < 100 erythrocytes per microliter. The best correlations of cell differentiation were seen for lymphocytes and neutrophils, while the results for monocytes and eosinophils were less precise. In some cases, considerable differences between automated and microscopic cell counts and differentiation were seen that were relevant to clinical decision making. The detection of pathologic cell types, such as hemosiderophages, mitoses and neoplastic cells, was not provided by automated cytometry. CONCLUSION: When experienced personnel are not available, a preliminary cell count and differentiation between neutrophilic and lymphocytic reactions by automated cytometry may be valuable in allowing initial therapeutic decision making. Since the detection of pathologic cell types is not provided and the precision at low cell counts is only moderate, a personal microscopic evaluation of each sample is still indispensable to avoid misdiagnoses.

Cell Count↗

Multicenter evaluation of analytical performance of the Liaison troponin I assay.

OBJECTIVES: This study evaluated the analytical characteristics of the Liaison immunoassay for cardiac troponin I (cTnI). DESIGN AND METHODS: The protocol consisted of eight sections: evaluation of antibody specificity, linearity, detection limit and imprecision, method comparison, evaluation of endogenous interferents, anticoagulant interference, sample stability, and reference values. RESULTS: The assay equally measured free and complexed cTnI. The minimum detectable cTnI concentration was 0.021 microg/l. The cTnI concentration corresponding to a total CV of 10% was 0.056 microg/l. Linearity of response was demonstrated along the entire dynamic range of the assay. Assay interferences were minimal. cTnI concentrations in serum and heparinized plasma were significantly different. Values in EDTA plasma were on average approximately 5% higher than in matched serum, but this difference was not significant. The 99th percentile cTnI value in healthy subjects was 0.036 microg/l. CONCLUSIONS: Being sensitive, specific, and precise, the Liaison cTnI assay meets current requirements to aid in the diagnosis of myocardial necrosis.

Adult↗

Multicenter analytical performance evaluation of the Elecsys proBNP assay.

The purpose of this multicenter study was to evaluate the technical performance of the automated Elecsys proBNP (brain natriuretic peptide) assay, which is indicated as an aid in the diagnosis of individuals suspected of having congestive heart failure. The Elecsys proBNP assay is an electrochemiluminescent immunoassay employing two polyclonal NT-proBNP-specific antibodies in a sandwich test format. The study was performed on the three Elecsys analyzers (E 1010, E 2010, and E 170) at eight different sites world-wide. Within- and total precision were < or = 3%, with total precision slightly higher on the Elecsys E 170 instrument with multiple modules. Reproducibility among sites and platforms was < 5%. Precision at particularly low NT-proBNP concentrations was assessed down to approximately 25 pg/ml with CVs of 12.6% at 29.2 pg/ml and 9.6% at 38.5 pg/ml for the Elecsys 1010/2010 and E 170, respectively. Linearity was evaluated up to 25,000 pg/ml with a sample-based non-linear response observed with recoveries of < 90% for proBNP concentrations < 10,000 pg/ml. Slopes ranged between 0.92 and 1.02 and intercepts from -5.3 to 10.4 pg/ml (r > or = 0.998) among the three types of analyzers. Slopes were 4.95 and 4.53 in comparison to the Biosite Triage and Shionogi BNP assays. There was no assay interference, and no effect of barrier gels, tube composition, or freeze-thaw. NT-proBNP concentrations in EDTA plasma were up to 10% lower than in serum or heparinized plasma and the analyte was stable at 4 degrees C for up to 72 hours (the maximum time tested). There was no circadian rhythm in normal subjects or congestive heart failure patients and there was no effect of drawing position. In summary, the Elecsys proBNP assay exhibits good technical performance and is suitable for use in routine clinical laboratories to aid in the diagnosis of congestive heart failure.

Evaluation Studies as Topic↗

Multicentre performance evaluation of the E170 module for modular analytics.

The E170 module was evaluated at 13 sites in an international multicentre study. The objective of the study was to assess the analytical performance of 49 analytes, and to collect feedback on the system's reliability and practicability. The typical, within-run coefficients of variation (CVs) for most of the quantitative assays ranged between 1 and 2% while a range of 2-4% was achieved with the infectious disease methods. Total precision CVs were found to be within the manufacturer's expected performance ranges, demonstrating good concordance of the system's measuring channels and a high reproducibility during the 2-4-week trial period. The functional sensitivity of 11 selected assays met the clinical requirements (e.g., thyreotroponin (TSH) 0.008 mU/l, troponin T 0.02 microg/l, total prostate-specific antigen (PSA) 0.03 microg/l). The E170 showed no drift during an 8-hour period and no relevant reagent carryover. Accuracy was confirmed by ring trial experiments and method comparisons vs. Elecsys 2010. The reliability and practicability of the system's hardware and software met with, or even exceeded, the evaluator's requirements. Workflow studies showed that E170 can cover the combined workload of various routine analysers in a variety of laboratory environment. Throughput and sample processing time requirements were achieved while personnel 'hands-on-time' could be reduced.

Calibration↗

Technical performance and diagnostic utility of the new Elecsys neuron-specific enolase enzyme immunoassay.

This international multicenter study was designed to evaluate the technical performance of the new double-monoclonal, single-step Elecsys neuron-specific enolase (NSE) enzyme immunoassay (EIA) and to assess its utility as a sensitive and specific test for the diagnosis of small-cell lung cancer (SCLC). Intra- and interassay coefficients of variation, determined in five control or serum specimens in six laboratories, ranged from 0.7 to 5.3 (inter-laboratory median: 1.3%) and from 1.3 to 8.5 (inter-laboratory median: 3.4%), respectively. Laboratory-to-laboratory comparability was excellent with respect to recovery and inter-assay coefficients of variation. The test was linear between 0.0 and 320 ng/ml (highest measured concentration). There was a significant correlation between NSE concentrations measured using the Elecsys NSE and the established Cobas Core NSE EIA II in all subjects (n = 723) and in patients with lung cancer (n = 333). However, NSE concentrations were systematically lower (approximately 9%) with the Elecsys NSE than with the comparison test. Based on a specificity of 95% in comparison with the group suffering from benign lung diseases (n = 183), the cut-off value for the discrimination between malignant and benign conditions was set at 21.6 ng/ml. NSE was raised in 73.4% of SCLC patients (n = 188) and was significantly higher (p < 0.01) in extensive (87.8%) as opposed to limited disease (56.7%). NSE was also elevated in 16.0% of the cases with non-small cell lung cancer (NSCLC, n = 374). It is concluded that the Elecsys NSE EIA is a reliable and accurate diagnostic procedure for the measurement of NSE in serum samples. The special merits of this new assay are the wide measuring range (according to manufacturer's declaration up to 370 ng/ml) and a short incubation time of 18 min.

Adenocarcinoma↗