Heart failure hospitalization is more common in pacemaker patients with sinus node dysfunction and a prolonged paced QRS duration.

OBJECTIVES: The purpose of this study was to determine whether a prolonged paced QRS duration increases the risk of cardiac dysfunction. BACKGROUND: Right ventricular apical pacing mimics left bundle branch block, results in a prolonged QRS duration of variable duration, and causes ventricular desynchronization. METHODS: In the Mode Selection Trial (MOST), QRS duration was measured in patients who had at least one paced ventricular complex recorded on 12-lead ECG within 3 months of enrollment (early) and after 9 months (late). Clinical endpoints including heart failure hospitalization, mortality, and atrial fibrillation were analyzed. A total of 1,026 patients were included in the analysis. Median age was 75 years (25th, 75th percentiles = 69, 80) and median ejection fraction prior to implant was 55% (45, 60). The cumulative percent ventricular pacing (DDDR and VVIR) was 81% over a median follow-up of 33 months. During period, 123 patients had heart failure hospitalization, 197 died, and 261 patients had atrial fibrillation. RESULTS: Cox proportional hazards models demonstrated that paced QRS duration was a strong predictor of heart failure hospitalization (hazard ratio 1.15; 95% confidence interval 1.07,1.23) for each 10-ms increase in paced QRS duration (P = .001). The increased risk was unaffected by adjustment for other known predictors of heart failure hospitalization in the study. Paced QRS duration was not significant for mortality (P = .41) or atrial fibrillation (P = .20) when baseline QRS duration and other predictors were included. CONCLUSIONS: Paced QRS duration is a significant, independent predictor of heart failure hospitalization in patients with sinus node dysfunction. A very long paced QRS duration is associated with increased heart failure hospitalization.

Aged↗

Clinical and quality of life comparison of accelerometer, piezoelectric crystal, and blended sensors in DDDR-paced patients with sinus node dysfunction in the mode selection trial (MOST).

INTRODUCTION: Permanent pacemakers are capable of increasing heart rate in response to physical activity by a variety of sensors including accelerometers, piezoelectric crystals, or blended sensors. The impact of these different physiologic sensors on cardiovascular events and quality of life is not known. METHODS: Of 2,010 patients randomized in the Mode Selection Trial, 1,245 patients were selected with the most commonly used pacemakers with these three sensors. Clinical characteristics and quality of life were compared between groups at baseline, 3 months, and then yearly. RESULTS: There were 449 patients with an accelerometer sensor device, 682 with a piezoelectric sensor, and 114 with a blended sensor. The groups were similar in terms of age (mean 74 years), gender, and cardiac risk factors but differences existed in weight, heart rate, mitral regurgitation, revascularization history, and drug therapy. The median ventricular pacing frequency was 80% (25th, 75th percentiles 42, 97). After a median follow-up of 33.1 months, the risk of death, heart failure hospitalization, atrial fibrillation, and the combined endpoint of mortality and stroke was not significantly different between the sensor types, after adjustment for baseline differences. Quality of life analyses demonstrated that patients with blended sensors had significantly worse (P < 0.01) physical function than did patients with the other two sensor systems. Moreover, patients receiving blended sensors had the poorest absolute scores, without reaching statistical significance, on 9 of 13 quality of life measures after adjusting for differences in the groups. CONCLUSION: We found no significant differences among the three most utilized sensors in clinical endpoints. Those patients who received blended sensors had worse physical function quality of life scores. However, clinical selection of the most sophisticated sensor for the most ill patients cannot be excluded as an explanation of these results.

Aged↗

Window to the heart: the value of a native and paced QRS duration. Current perspective and review.

Given the technological advances and reliance upon expensive testing for guiding therapy, it is surprising how an inexpensive, low tech electrocardiogram can provide a wealth of information pertaining to the underlying cardiovascular status of a patient. In this article we review the changes in hemodynamics, prognosis and guidance of therapeutic options associated with a prolonged QRS duration.

Bundle-Branch Block↗

High defibrillation thresholds in transvenous biphasic implantable defibrillators: clinical predictors and prognostic implications.

The aim of this study was to identify clinical characteristics that distinguish patients with high DFTs and assess the prognostic implication. DFTs testing is a lengthy, potentially painful, and a hazardous process. Little information is available concerning the identification of patients with high DFT who undergo ICD surgery with transvenous leads and biphasic energy. This study analyzed 968 patients from two separate clinical studies who received a Medtronic cardioverter defibrillator from January 1995 through November 1999 and who had DFT testing measured by a binary search protocol. Compared to 865 patients with low defibrillation thresholds (< 18 J), the 103 patients with high thresholds (> or = 18 J) had a lower LVEF (34 +/- 16.7 vs 38.3 +/- 16.2%, P = 0.01), a worse NYHA functional class (23% Class I, 43% Class II, 29% Class III, 5% Class IV vs. 27% Class I, 55% Class II, 17% Class III, 1% Class IV, P < 0.0001), had bypass surgery less often (10.7 vs 27.5%, P < 0.0001), used amiodarone within the past 6 weeks (42.7 vs 27.2%, P = 0.002), and had a history of ventricular fibrillation more often (44.7 vs 33.1%, P = 0.02). Information concerning the number of shocks delivered was available in 345 (35%) patients; 23 were in the high DFT group and 322 were in the low DFT group. Twelve (52%) of the 23 patients in the high DFT arm received 3.6 +/- 2.7 shocks (median 2.5) and 106 (33%) of the 322 patients with low DFT received 4.9 +/- 9.5 shocks (median 2). After 6 months the mortality rate of patients with high thresholds was 11.7 vs 7.8% in patients with low thresholds (P = 0.118). Using a multivariate logistic regression model the significant predictors of death were older age, higher NYHA class, lower LVEF, amiodarone use, had a presenting arrhythmia of ventricular fibrillation and CHF but not initial high defibrillation thresholds. The study found that (1) 11% of patients have high DFTs, (2) clinical characteristics that identify high defibrillation thresholds are NYHA Class III, IV, low ejection fraction, no previous history of bypass surgery, prior amiodarone use preoperatively, and presenting with ventricular fibrillation, and (3) while high DFTs were associated with a more ill patient population, there was no difference in survival in a 6-month follow-up. Patients with a predicted low DFTs may be eligible for abbreviated ICD testing while high risk patients require formal testing.

Case-Control Studies↗