PubMed Health⌕ Search

Biomedical subjects

Hiroko Ohta

Publications and source records attributed to Hiroko Ohta.

3 recordsLinked to original sources

Electrochemical probe for on-chip type flow immunoassay: immunoglobulin G labeled with ferrocenecarboaldehyde.

Labeling of ferrocenecarboaldehyde (Fc-CHO) to immunoglobulin G (IgG) via formation of Schiff-base and its reduction was investigated for construction of an electrochemical probe for miniaturized amperometric flow immunoassay. Approximately eight molecules of Fc-CHO were labeled to IgG and the reversible redox property of ferrocene was observed. Labeling efficiency improved by over three times as compared to the conventional method using ferrocenemonocarboxylic acid (Fc-COOH). Also, binding affinity of IgG labeled with Fc-CHO to its antigen, IgE, was investigated by enzyme-linked immunosorbent assay (ELISA) and surface plasmon resonance assay. IgG labeled with Fc-CHO that retained eight ferrocene moiety showed sufficient binding affinity to its antigen and the current response obtained in the flow electrochemical detection system increased by 14-fold as compared with IgG labeled with Fc-COOH when applying the potential of 390 mV vs. Ag/AgCl. The minimum detectable concentration of IgG labeled with Fc-CHO was 0.06 microM. IgG labeled with Fc-CHO demonstrate biochemical and electrochemical properties that are useful for electrochemical immunosensors.

Animals↗

Capturing of acidic macromolecules from biological samples using a temperature-responsive polymer modified with poly-l-lysine.

We synthesized a temperature-responsive polymer, N-(isopropylacrylamide)-methacrylic acid copolymer, to which poly-l-lysine was introduced. The synthesized polymer as well as the parent polymer showed reversible soluble-insoluble changes in response to temperature changes across the lower critical solution temperature at 32 degree C in an aqueous solution. We found that the polymer efficiently captured acidic bio-macromolecules such as RNA, glycosaminoglycans and mucin-type glycoproteins in biological samples, and the captured molecules were recovered using aqueous NaCl solutions at high concentration. The target acidic molecules thus obtained will be employed for further studies such as structural analysis after brief desalting procedure. The proposed method does not require any chromatographic separations, but only needs a small volume of an aqueous salt solution for releasing captured molecules. Overall procedures are quite easy and simple, and are completed at least within 1 h. We show a few examples for capturing RNA and glycosaminoglycans from cultured cells using the polymer.

Acrylamides↗

Microfabricated on-chip-type electrochemical flow immunoassay system for the detection of histamine released in whole blood samples.

This paper describes an on-chip-type electrochemical flow immunoassay system with a multichanneled matrix column. The multichanneled matrix column was functionally coated with cation-exchange resin and used for separation of proteins. Antihistamine immunoglobulin G (IgG) antibody conjugated with ferrocenemonocarboxylic acid (Fc) was also prepared and used as a novel analytical reagent. Antibody-antigen complexes were separated from free Fc-conjugated IgG antibody (Fc-IgG) on the basis of differences in isoelectric point (pI) using the multichanneled matrix column coated with cation-exchange resin. The assay yields a good relationship between current and histamine concentration in the range of 200-2000 ng/mL. This simple technique enables the assay of histamine released in whole blood within 2 min. Furthermore, a good correlation was found between the response of the electrochemical immunoassay described in this paper and the conventional RIA (radioimmunoassay). This on-chip-type electrochemical flow immunoassay requires only minute quantities of whole blood samples and generates highly reproducible results.

Electrochemistry↗