PubMed Health⌕ Search

Biomedical subjects

Hiroko Okazaki

Publications and source records attributed to Hiroko Okazaki.

4 recordsLinked to original sources

Investigation of misfiled cases in the PACS environment and a solution to prevent filing errors for chest radiographs.

RATIONALE AND OBJECTIVE: The aim of the study was to survey misfiled cases in a picture archiving and communication system environment at two hospitals and to demonstrate the potential usefulness of an automated patient recognition method for posteroanterior chest radiographs based on a template-matching technique designed to prevent filing errors. MATERIALS AND METHODS: We surveyed misfiled cases obtained from different modalities in one hospital for 25 months, and misfiled cases of chest radiographs in another hospital for 17 months. For investigating the usefulness of an automated patient recognition and identification method for chest radiographs, a prospective study has been completed in clinical settings at the latter hospital. RESULTS: The total numbers of misfiled cases for different modalities in one hospital and for chest radiographs in another hospital were 327 and 22, respectively. The misfiled cases in the two hospitals were mainly the result of human errors (eg, incorrect manual entries of patient information, incorrect usage of identification cards in which an identification card for the previous patient was used for the next patient's image acquisition). The prospective study indicated the usefulness of the computerized method for discovering misfiled cases with a high performance (ie, an 86.4% correct warning rate for different patients and 1.5% incorrect warning rate for the same patients). CONCLUSION: We confirmed the occurrence of misfiled cases in the two hospitals. The automated patient recognition and identification method for chest radiographs would be useful in preventing wrong images from being stored in the picture archiving and communication system environment.

Database Management Systems↗

Improved detection of lung cancer arising in diffuse lung diseases on chest radiographs using temporal subtraction.

RATIONALE AND OBJECTIVES: The purpose of this study was to evaluate the usefulness of temporal subtraction for the detection of lung cancer arising in pneumoconiosis, idiopathic pulmonary fibrosis, and pulmonary emphysema. MATERIALS AND METHODS: Fifteen cases of lung cancer arising in diffuse lung diseases, including three cases of pneumoconiosis, six of idiopathic pulmonary fibrosis, and six of pulmonary emphysema, were evaluated. Pathologic proof was obtained by surgery or transbronchial lung biopsy. The average interval between previous and current radiographs was 356 days (range, 31-947 days). All chest radiographs were obtained with a computed radiography system, and temporal subtraction images were produced by subtracting of a previous image from a current one with a nonlinear image-warping technique. The effect of the temporal subtraction image was evaluated by observer performance study with receiver operating characteristic analysis. RESULTS: The average observer performance with temporal subtraction was significantly improved (Az = 0.935) compared with that without temporal subtraction (Az = 0.857, P < .0001). CONCLUSION: The temporal subtraction technique is useful for the detection of lung cancer arising in pneumoconiosis, idiopathic pulmonary fibrosis, and pulmonary emphysema.

Adenocarcinoma↗

[Effect of tonometry on a glaucoma population study].

PURPOSE: The purpose of this study was to evaluate the influence of tonometry in detecting the occurrence of glaucoma. METHODS: The subjects, 845 out of 3,488 residents aged 40 years or older, were examined according to standard protocols, including tonometry, slit lamp examination, fundus photography, and automatic perimetry as a recall examination. The intraocular pressure in each subject was measured by both Goldmann applanation tonometer(GAT) and noncontact tonometer CT-70 (NCT). RESULTS: The mean +/- standard deviation intraocular pressure measured by GAT was 15.52 +/- 2.57 mmHg, and 15.03 +/- 2.90 mmHg by NCT. There was a statistically significant correlation(p < 0.0001). The difference between pairs of measurements by GAT and NCT was 0.50 +/- 1.93 mmHg. There was no influence of tonometry in detecting the incidence of glaucoma, which was 4.14%; primary open-angle glaucoma 0.59%, normal tension glaucoma 2.6%, primary angle-closure glaucoma 0.47%, and other types of glaucoma 0.48%. The detection of ocular hypertension was different, and was 2.13% with GAT and 2.72% with NCT. CONCLUSION: In our study, the influence of tonometry in detecting the incidence of glaucoma was very small. A noncontact tonometer is considered to be useful for glaucoma population study.

Adult↗