PubMed Health⌕ Search

Biomedical subjects

Hiroko Satake

Publications and source records attributed to Hiroko Satake.

At least 19 recordsLinked to original sources

CT depiction of small arteries in the pancreatic head: assessment using coronal reformatted images with 16-channel multislice CT.

BACKGROUND: To assess the capabilities of 16-channel multislice CT in acquiring almost exclusively arterial-phase images of the pancreas and depicting small pancreatic arteries in coronal reformatted images. MATERIALS AND METHODS: In 45 consecutive patients, arterial-phase contrast enhancement was measured in the aorta and its branches, portal venous system, and pancreas. Coronal reformatted images of 1.2- or 1.3-mm slice thickness at 0.8- or 0.9-mm intervals were generated from axial images acquired with 0.5-mm collimation. Two radiologists evaluated the quality of imaging in the arterial phase and the visibility of the pancreatic arteries in coronal reformatted images. RESULTS: Mean enhancement in the aorta and its branches was greater than 300 HU, while that in the portal venous system and pancreas was less than 100 HU. The images were judged to be suitable for delineating the pancreatic arteries in all patients. The following arteries were visualized: anterior superior pancreaticoduodenal (39 patients), posterior superior pancreaticoduodenal (41), anterior inferior pancreaticoduodenal (39), posterior inferior pancreaticoduodenal (33), dorsal pancreatic (42), its right branch (34), and transverse pancreatic (37). CONCLUSION: Multislice CT can depict small pancreatic arteries using coronal reformatted images generated from almost exclusively arterial-phase axial images acquired with 0.5-mm collimation.

Adult↗

Diagnostic value of curved multiplanar reformatted images in multislice CT for the detection of resectable pancreatic ductal adenocarcinoma.

The purpose of this study was to assess the usefulness of curved multiplanar reformatted (MPR) images obtained by multislice CT for the depiction of the main pancreatic duct (MPD) and detection of resectable pancreatic ductal adenocarcinoma. This study included 28 patients with pancreatic carcinoma (size range 12-40 mm) and 22 without. Curved MPR images with 0.5-mm continuous slices were generated along the long axis of the pancreas from pancreatic-phase images with a 0.5- or 1-mm slice thickness. Seven blinded readers independently interpreted three sets of images (axial images, curved MPR images, and both axial and curved MPR images) in scrolling mode. The depiction of the MPD and the diagnostic performance for the detection of carcinoma were statistically compared among these images. MPR images were significantly superior to axial images in depicting the MPD, and the use of both axial and MPR images resulted in further significant improvements. For the detection of carcinoma, MPR images were equivalent to axial images, and the diagnostic performance was significantly improved by the use of both axial and MPR images. High-resolution curved MPR images can improve the depiction of the MPD and the diagnostic performance for the detection of carcinoma compared with axial images alone.

Adult↗

The effect of patient age on contrast enhancement during CT of the pancreatobiliary region.

OBJECTIVE: The objective of our study was to assess whether it is possible to reduce the dose and rate of contrast material injection in elderly patients in triple-phase contrast-enhanced CT of the pancreatobiliary region with an MDCT scanner. SUBJECTS AND METHODS: One hundred twelve patients were divided into three groups: contrast injection at 0.08 mL/kg body weight/s (an upper limit of 5 mL/s) over 30 seconds in patients 60 years old or younger (group 1, n = 49), the same contrast injection as group 1 in patients more than 60 years old (group 2, n = 32), and contrast injection at 0.07 mL/kg body weight/s (an upper limit of 4.5 mL/s) over 30 seconds in patients more than 60 years old (group 3, n = 31). Contrast enhancement in the aorta, portal venous system, pancreas, and liver was assessed quantitatively. Two radiologists blinded to the patients' clinical information and the injection protocol used to acquire the CT images graded the degree of contrast enhancement using a 5-point scoring system. The results for the different groups were statistically compared. RESULTS: Contrast enhancement in the main phases for all organs was significantly more intense in group 2 than in groups 1 and 3. Cases in which pancreatic enhancement in the pancreatic phase was graded as excessive were more frequently observed in group 2. No statistically significant differences were observed between groups 1 and 3 in either quantitative or visual assessment for enhancement of any organ in any phase. CONCLUSION: We recommend reducing the dose and rate of contrast material injection by at least 10% for elderly patients undergoing MDCT examination of the pancreatobiliary region.

Adult↗

Assessment of anomalous pancreaticobiliary ductal junction with high-resolution multiplanar reformatted images in MDCT.

OBJECTIVE: The objective of our study was to assess the capabilities of MDCT for the diagnosis of an anomalous pancreaticobiliary ductal junction using high-resolution multiplanar reformatted (multiplanar reconstruction) images. MATERIALS AND METHODS: This study included nine patients with and 54 without an anomalous pancreaticobiliary ductal junction confirmed on direct cholangiopancreatography. Multiplanar reconstruction images with 0.5-mm continuous slices were generated from isotropic or nearly isotropic pancreatic phase images. By mainly interpreting the multiplanar reconstruction images using the Scrolling mode, two blinded reviewers independently determined whether the confluence of the pancreatic and biliary ducts joined in the pancreatic parenchyma (in other words, outside the duodenal wall). The results were correlated with the findings of direct cholangiopancreatography. The diagnostic capabilities of CT for revealing associated pancreatobiliary diseases were assessed in patients with this anomaly. RESULTS: Interobserver agreement in the classification of the duct confluence was high (kappa = 0.804). The duct confluence was identified in all patients except four without an anomalous pancreaticobiliary ductal junction. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of CT for diagnosing an anomalous pancreaticobiliary ductal junction were 100% (9 of 9 patients), 87% (47 of 54 patients), 89% (56 of 63 patients), 75% (9 of 12 patients), and 100% (47 of 47 patients) in the final decisions, respectively. CT showed all associated pancreatobiliary diseases except bile duct stones in two patients. CONCLUSION: MDCT enabled the diagnosis of an anomalous pancreaticobiliary ductal junction by showing whether the pancreatic and biliary ducts join within the pancreatic parenchyma on high-resolution multiplanar reconstruction images.

Adult↗

Non-palpable and non-invasive ductal carcinoma with bloody nipple discharge successfully resected after cancer spread was accurately diagnosed with three-dimensional computed tomography and galactography.

A case of ductal carcinoma in situ (DCIS) that was treated by partial mastectomy is reported. The operation was performed after accurate estimation of cancer spread by three-dimensional computed tomography (3D-CT). The patient was a 39-year-old woman without a palpable lump who had a bloody nipple discharge. Ultrasonography showed distended mammary ducts with intraductal components. Fine needle aspiration cytology revealed ductal carcinoma. Galactography showed two subsegmental ducts and peripheral branches in the upper-inner quadrant of the right breast. 3D-CT depicted a well enhanced segmental-clumped lesion including two subsegments of a duct lobular system shown in galactograms. DCIS was diagnosed and partial mastectomy following the video assisted thoracoscopic surgery (VATS) marker insertion was performed, after cancer spread was accurately diagnosed by 3D-CT guidance. DCIS resected by minimally sufficient partial mastectomy with negative surgical margins was diagnosed histopathologically.

Adult↗

Application of subsecond rotation scan to helical CT for lung cancer screening.

PURPOSE: To clarify whether the benefit of a reduced effective scan width obtained using a smaller pitch outweighs the disadvantage of increased noise in the application of a subsecond helical CT to mass screenings for lung cancer. MATERIALS AND METHODS: Twenty-two helical CT scans of the lung were obtained in 11 healthy subjects using the following parameters: 1) scan 1 was performed at 120 kVp, 50 mA, 10-mm collimation, 1-second/rotation, helical pitch of 2.0; and 2) scan 2 was performed at 120 kVp, 50 mA, 10-mm collimation, 0.75-second/rotation, helical pitch of 1.5. Computer-generated nodules measuring 10 mm and 6 mm in diameter showing ground-glass opacity were superimposed on these images. The detectability of each nodule was evaluated by six blinded readers using ROC analysis. RESULTS: Detectability of the 6-mm nodules was significantly higher in scan 2 than in scan 1. Detectability of the 10-mm nodules was not significantly different between scans 1 and 2. CONCLUSION: The use of a smaller pitch by employing a subsecond rotation scan in a helical CT for lung cancer screenings improves the detection of small lesions without increasing either the scanning time or radiation dose.

Adult↗

Intra- and interobserver agreement and performance score of breast phantom image interpretation: influence of ambient room lighting levels.

The influence of ambient room lighting conditions on soft-copy breast phantom image interpretation was evaluated by comparing cathode ray tube (CRT) monitors with liquid crystal displays (LCDs). Nine observers were asked to use a three-point scale to rate the visibility of various phantom objects (masses, specks, and fibers) displayed on a 21-inch CRT (2,560 x 2,048) and a 21-inch LCD (2,560 x 2,048) under three different levels of ambient lighting (20, 100 and 420 lux at the display center). Each phantom image was interpreted twice, and the reproducibility of judgment and inter-observer agreement was evaluated using kappa statistics. Except for the "mass" score, the LCD score showed a significantly higher value (p<0.05) compared with that of CRT. Nevertheless, no significant differences were found among the three lighting levels. Furthermore, intra- and inter-observer agreement in judgments showed no effects of room illumination. Although the breast phantom objects were better visualized on LCDs than on CRT monitors, room illumination did not affect the performance score of soft-copy reading.

Breast Neoplasms↗

Branch duct-type intraductal papillary mucinous tumor: diagnostic value of multiplanar reformatted images in multislice CT.

The object of this study was to evaluate the usefulness of high-resolution multiplanar reformatted (MPR) images obtained by multislice CT in demonstrating connection between pancreatic cystic lesions and the main pancreatic duct. The study included 27 lesions with connection to the main pancreatic duct and 12 lesions without. All but one of the former lesions were branch duct-type intraductal papillary mucinous tumors (IPMTs). Oblique and curved MPR images with 0.5 mm continuous slices were generated from pancreatic-phase axial images reconstructed with 0.5 mm or 1 mm thickness at 0.5 mm intervals over a 260 mm field of view. The diagnostic capabilities for demonstrating connection with the main pancreatic duct were compared among axial images, MPR images, and both axial and MPR images in combination using the Brier score. The diagnosis in MPR images for demonstrating connection was more certain than that in axial images (P<0.05). Compared with MPR images alone, the use of both axial and MPR images resulted in further improvements in diagnostic performance, although the difference was not statistically significant. The use of high-resolution MPR images significantly improves diagnostic performance for demonstrating connection between pancreatic cystic lesions and the main pancreatic duct, which is useful for the diagnosis of branch duct-type IPMT.

Adenocarcinoma, Mucinous↗

Multiphase contrast-enhanced CT of the liver with a multislice CT scanner: effects of iodine concentration and delivery rate.

PURPOSE: To determine whether or not high-concentration contrast material is useful in multiphase contrast-enhanced CT of the liver with a multislice CT scanner. MATERIALS AND METHODS: One hundred twenty-four examinations, in which first- and second-pass acquisitions (double arterial phase imaging) were performed during a single breath-hold followed by third-pass acquisition, were randomized into three protocols: contrast injection at 0.07 mL/kg body weight/sec over 30 sec at an iodine concentration of 300 mgI/mL in group 1, contrast injection at 0.06 mL/kg body weight/sec over 30 sec at an iodine concentration of 350 mgI/mL in group 2, and contrast injection at 0.07 mL/kg body weight/sec over 25.7 sec at an iodine concentration of 350 mgI/mL in group 3. Each group received an equivalent iodine dose per kg body weight (2.1 mL/kg of contrast material of 300 mgI/mL). Contrast enhancement in each acquisition was measured in the aorta, portal vein, and liver. RESULTS: No statistically significant differences were seen between groups 1 and 2 in any enhancement in any acquisition. In group 3, aortic enhancement in the first-pass acquisition was significantly more intense than in groups 1 and 2, while portal venous enhancement and hepatic enhancement were equivalent. CONCLUSION: Shortening the injection duration for a given iodine dose with high-concentration contrast material (group 3) can achieve improved arterial enhancement on arterial phase images.

Adult↗

Three-phase CT examination of the pancreatobiliary region using multislice CT with 1-mm collimation.

PURPOSE: To evaluate the degree of contrast enhancement and accuracy of imaging of the circulatory phase in the first-pass, second-pass, and third-pass acquisitions in the pancreato-biliary region with 1-mm collimation obtained by multislice computed tomography (CT). MATERIALS AND METHODS: In 53 patients, two sequential acquisitions from the porta hepatis to the pancreas were performed during a single breath-hold, followed by a third-pass acquisition including the liver beginning 15 sec after the second-pass acquisition. Contrast enhancement in each acquisition was measured in the aorta, portal vein and its branches, and pancreas. Four experienced radiologists graded using four-point scoring whether or not each acquisition was appropriate for imaging of the arterial phase, pancreatic phase, and portal venous phase. RESULTS: Aortic enhancement was highest at the beginning of the second-pass acquisition. The portal and splenic veins and pancreas showed maximum enhancement in the second-pass acquisition, while the superior mesenteric vein showed maximum enhancement in the third-pass acquisition. In the visual assessment, significantly higher grades were achieved in the first-pass, second-pass, and third-pass acquisitions with regard to imaging of the arterial phase, pancreatic phase, and portal venous phase, respectively. CONCLUSION: Multislice CT permits the acquisition of three distinct circulatory phases (arterial, pancreatic, and portal venous phases) in the pancreatobiliary region with 1-mm collimation.

Adult↗

Late-arterial and portal-venous phase imaging of the liver with a multislice CT scanner in patients without circulatory disturbances: automatic bolus tracking or empirical scan delay?

The value of automatic bolus tracking in late-arterial and portal-venous phase imaging of the liver with a multislice CT scanner as compared with fixed time-delay examination in patients without circulatory disturbances is evaluated. For the evaluation of known or suspected liver disease, 98 multiphase contrast-enhanced CT examinations including double late-arterial phase imaging were randomized into either scanning with a scan delay of 30 s from the beginning of contrast material injection or scanning with automatic bolus tracking. Contrast material was injected at 0.07 ml/kg body weight/s over 30 s. Contrast enhancement in each acquisition was measured in the aorta, portal vein, liver, pancreas and hepatocellular carcinomas. The density difference between hepatocellular carcinomas and the hepatic parenchyma was calculated. The mean time to the first-pass acquisition as determined by automatic bolus tracking was 29.6 s. No statistically significant difference was observed between the two groups either in any enhancement in any acquisition or in the lesion-to-liver density difference. The use of automatic bolus tracking in late-arterial and portal-venous phase hepatic CT does not significantly improve the degree of contrast enhancement in the aorta, portal vein, liver and pancreas or lesion-to-liver conspicuity in patients without circulatory disturbances.

Adult↗

Multiphase contrast-enhanced CT of the liver with a multislice CT scanner.

Our objective was to assess the effects of the injection rate of contrast material and of a 5% dextrose flush on enhancement in multiphase hepatic CT using a multislice CT scanner. Most patients had chronic hepatitis and/or liver cirrhosis. One hundred eighty examinations, in which two sequential acquisitions were performed during a single breath-hold followed by third- and fourth-pass acquisitions, were randomized into four protocols: contrast injection at 0.1 ml/kg body weight s(-1) over 21 s without and with a 30-ml flush in groups 1 and 2, respectively, and contrast injection at 0.07 ml/kg body weight s(-1) over 30 s without and with a flush in groups 3 and 4, respectively. Contrast enhancement in each acquisition was measured in the aorta, portal vein, and liver. The visualization of hepatic arterial branches was scored by visual assessment. The highest aortic enhancement was observed in the first-pass acquisition in all groups. At the higher injection rate (groups 1 and 2), aortic enhancement in the first-pass acquisition was significantly more intense, whereas portal venous and hepatic enhancement was significantly less intense. The use of a flush considerably improved aortic enhancement at the beginning of the second-pass acquisition. In the visual assessment of hepatic arterial branches, the protocols with the higher injection rate received significantly higher grades. Multislice CT permits the entire liver to be imaged during an almost exclusively arterial phase by shortening the injection duration for a given volume of contrast material.

Adult↗

Assessment of the pancreatic and intrapancreatic bile ducts using 0.5-mm collimation and multiplanar reformatted images in multislice CT.

Our objective was to evaluate the ability of multiplanar reformatted (MPR) images combined with 0.5-mm axial images to depict the pancreatic and intrapancreatic bile ducts and compare the results with those of 0.5-mm axial, 2-mm axial, and 6-mm axial images alone. Seventy-seven patients without obstruction of the main pancreatic ducts (MPD) underwent dual-phase helical scanning of the pancreas using multislice computed tomography (MSCT). The MPR images were generated from 0.5-mm-thick images. Visualization of the pancreatic and intrapancreatic bile ducts and their confluence was graded on a four-point scale by a consensus of two radiologists. The results for 0.5-mm axial images in early-phase CT, 2-mm axial images in early-phase CT, MPR images combined with 0.5-mm axial images in early-phase CT, and 6-mm axial images in late-phase CT were then compared. The relationships of the focal pancreatic lesions with the pancreatic ducts were analyzed. The MPR images combined with 0.5-mm axial images were significantly superior to the other three types of images for the visualization of the pancreatic and intrapancreatic bile ducts and their confluence (p<0.01). The depiction rate of the MPD using MPR images combined with 0.5-mm axial images was 94, 94, 95, and 75%, respectively in the head, neck, body, and tail of the pancreas. Accessory pancreatic ducts, intrapancreatic bile ducts, and duct confluence were depicted in 48, 99, and 92%, respectively. In comparison with evaluation based on axial images alone, the use of MPR images more clearly demonstrated the relationship between the lesions and the pancreatic ducts in 14 of 19 lesions. The MPR images combined with 0.5-mm axial images improve the CT depiction of the pancreatic and intrapancreatic bile ducts in comparison with 0.5-mm axial, 2-mm axial, and 6-mm axial images alone.

Adult↗

Interobserver agreement and performance score comparison in quality control using a breast phantom: screen-film mammography vs computed radiography.

Our objective was to evaluate interobserver agreement and to compare the performance score in quality control of screen-film mammography and computed radiography (CR) using a breast phantom. Eleven radiologists interpreted a breast phantom image (CIRS model X) by four viewing methods: (a) original screen-film; (b) soft-copy reading of the digitized film image; (c) hard-copy reading of CR using an imaging plate; and (d) soft-copy reading of CR. For the soft-copy reading, a 17-in. CRT monitor (1024x1536x8 bits) was used. The phantom image was evaluated using a scoring system outlined in the instruction manual, and observers judged each object using a three-point rating scale: (a) clearly seen; (b) barely seen; and (c) not seen. For statistical analysis, the kappa statistic was employed. For "mass" depiction, interobserver agreement using CR was significantly lower than when using screen-film ( p<0.05). There was no significant difference in the kappa value for detecting "microcalcification"; however, the performance score of "microcalcification" on CR hard-copy was significantly lower than on the other three viewing methods ( p<0.05). Viewing methods (film or CR, soft-copy or hard-copy) could affect how the phantom image is judged. Paying special attention to viewing conditions is recommended for quality control of CR mammograms.

Female↗

The role of contrast-enhanced MR mammography for determining candidates for breast conservation surgery.

PURPOSE: The aim of this study was to assess the impact of preoperative magnetic resonance mammography (MRM) on the surgical determination of breast conservation treatment for breast cancer patients. METHODS: From September 1997 to March 2000, 57 consecutive breast conservation treatment candidates were prospectively evaluated with conventional imaging studies (mammography and ultrasonography) and preoperative MRM. RESULTS: In 47 of 54 (87% ) breast cancer patients breast conservation surgery (BCS) was indicated on the basis of mammography (MMG) and ultrasonography (US). However in 40 of the 54 (74% ) patients BCS was indicated on the basis of MRM. Thirty-eight of the 40 patients ultimately underwent BCS and only 1 showed a positive margin. There were 7 patients whose MRM findings suggested that more aggressive treatment than BCS was needed but for whom US/MMG suggested that BCS was appropriate. Five of the 7 patients underwent mastectomy rather than BCS based on the MRM findings, which were justified by post-surgical histological findings. Of the 2 remaining patients who underwent BCS, one had a positive histological margin and one had recurrence, both of which resulted in salvage mastectomy. CONCLUSION: Our study suggests that high resolution preoperative MRM provides more accurate information compared with US and MMG for selecting candidates for BCS. Using MRM as a routine staging tool may reduce unnecessary repeated excisions. A larger study will be required to confirm these findings and to define the patients most likely to benefit from breast MR imaging.

Adult↗

Lung: feasibility of a method for changing tube current during low-dose helical CT.

A method for changing the tube current during helical scanning was applied to low-dose computed tomography (CT) in the lung. The changing method resulted in significant equalization of image noise in various lung sections compared with that at scanning with constant tube current. Detectability of nodules was equivalent between 60 mA and the changing method, whereas degradation occurred at 20 mA. This method seems feasible for the low-dose CT of lung cancer screening.

Humans↗

Solitary pulmonary nodules: optimal slice thickness of high-resolution CT in differentiating malignant from benign.

The purpose of this study was to determine an optimal slice thickness that was efficient in differentiating malignant from benign solitary pulmonary nodules (SPNs) on high-resolution computed tomography (HRCT) images. For a total of 92 SPNs, four radiologist indicated their confidence level for the malignant or benign SPN on the CT images presented in 1-, 3-, and 5-mm slice thickness. HRCT could be used to differentiate more accurately the malignant nodules from the benign ones using 1-mm-thick sections than 3- or 5-mm-thick sections.

Adult↗

Diagnostic value of multislice computed tomography for pancreas divisum: assessment with oblique coronal reconstruction images.

OBJECTIVES: To assess the capabilities of high-resolution oblique coronal reconstruction images obtained by multislice computed tomography (CT) in diagnosing pancreas divisum. METHODS: This study included 11 patients with and 53 without pancreas divisum confirmed by direct cholangiopancreatography. Two blinded readers retrospectively interpreted oblique coronal reconstruction images with 0.5-mm continuous slices generated from isotropic or nearly isotropic pancreatic phase images with the scrolling mode and assessed the continuity of the ventral pancreatic duct, dorsal pancreatic duct, and main pancreatic duct in the body. The results were correlated with the findings of direct cholangiopancreatography. Other abnormal findings of the pancreatobiliary region on CT were also recorded in patients with pancreas divisum. RESULTS: The sensitivity and specificity of CT for diagnosing pancreas divisum were 100% and 89%, respectively. Computed tomography demonstrated all associated pancreatobiliary diseases. CONCLUSION: High-resolution oblique coronal reconstruction images allow us to make a diagnosis of pancreas divisum by depicting the continuity of the pancreatic ducts.

Adult↗