PubMed Health⌕ Search

Biomedical subjects

Hiromichi Yoshida

Publications and source records attributed to Hiromichi Yoshida.

4 recordsLinked to original sources

A flexible and wearable glucose sensor based on functional polymers with soft-MEMS techniques.

A novel biosensor for glucose measurement using functional polymers was fabricated and tested. The biosensor utilizes the physical and chemical functions of hydrophobic polydimethyl siloxane (PDMS) and hydrophilic 2-methacryloyloxyethyl phosphorylcholine (MPC) copolymerized with dodecyl methacrylate (DMA). The glucose sensor was constructed by immobilizing glucose oxidase (GOD) onto a flexible hydrogen peroxide electrode (Pt working electrode and Ag/AgCl counter/reference electrode). The electrodes were fabricated using microelectromechanical systems (MEMS) techniques onto those functional polymers. The sensor showed novel functions of flexibility and it was stretchable so that the sensor could normally work when it was released after expanding to 120% longer than that of normal length. Also, basic characteristics of the sensor were evaluated. The output current of the hydrogen peroxide electrode was linearly related to the hydrogen peroxide concentration in a range of 0.20-2.50 mmol/l, with a correlation coefficient of 0.998. GOD was then immobilized onto the surface of the sensor using MPC polymer. In this case, the current output of the glucose sensor related to the glucose level over a range of 0.06-2.00 mmol/l, with a correlation coefficient of 0.997. The calibration range includes the reported concentration of tear glucose in normal human subject (0.14 mmol/l).

Blood Glucose Self-Monitoring↗

Determination of optical isomers for left-handed or right-handed chiral double-wall carbon nanotubes.

The handedness relationship between adjacent layers in nested double-wall carbon nanotubes (DWNTs) has been investigated for the first time. Our high-resolution electron microscopy analysis on a series of specimen tilts can successfully tell the handedness of each constituent nanotube in a DWNT, and therefore the chiral indices (n, m) including their optical isomers [(n, m) or (m, n)] of inner and outer nanotubes can be uniquely determined. It is shown that right-handed and left-handed nanotubes are equally distributed for both the inner and outer nanotubes in the examined specimens and a preferable handedness relationship between the adjacent layers in DWNT may exist.

Journal Article↗

The role of self-report questionnaire in the screening of postnatal depression- a community sample survey in central Tokyo.

BACKGROUND: Numerous studies have shown that health care professionals often experience difficulty in detecting postnatal depression. In Japan, where mental illness has traditionally been stigmatized, detection seems even more difficult. This study investigates the prevalence of postnatal depression in the community and its relation to screening methodology. METHODS: The Edinburgh Postnatal Depression Scale (EPDS) was distributed at community health centers in a district in central Tokyo. The results from both non-identifiable questionnaires and identifiable questionnaires were compared. Screening by EPDS and clinical judgment by community nurses were compared. RESULTS: Making the questionnaire identifiable did not change the score distribution pattern. Among mothers with 3- to 4-month-old babies in the community, 13.9% scored high (9 or above) on EPDS. In 51.1% of high scorers,nurses did not detect postnatal depression. Clinically, postnatal depression can be easily missed in the community health-check setting especially when there was hitherto no report of obstetric abnormality during pregnancy or delivery. CONCLUSION: The prevalence of high scorers is comparable to those reported in other countries. The use of the questionnaire was helpful in drawing the attention of mothers and health care professionals to issues of mental health.

Adult↗

Imidapril-induced eosinophilic pleurisy. Case report and review of the literature.

We describe an unusual case of a patient with eosinophilic pleurisy associated with long-term administration of imidapril, an angiotensin-converting enzyme inhibitor (ACEI). An 81-year-old woman who had been given imidapril for the treatment of essential hypertension was admitted to our hospital for investigation of persistent low-grade fever, dry cough and difficulty in breathing. Left-sided eosinophilic pleurisy was diagnosed based on eosinophilic pleural effusion and peripheral eosinophilia. Soon after administration of imidapril was discontinued, her clinical symptoms subsided, and there was improvement in both diagnostic imaging and laboratory findings. So far, to our knowledge, this is the first reported case in which ACEI induced eosinophilic pleurisy.

Aged↗