PubMed Health⌕ Search

Biomedical subjects

Hironobu Morisaka

Publications and source records attributed to Hironobu Morisaka.

4 recordsLinked to original sources

Two-dimensional HPLC on-line analysis of phosphopeptides using titania and monolithic columns.

Conventional and comprehensive two-dimensional (2D) HPLC systems using the combination of titania and monolithic columns were established for the on-line analysis of phosphopeptides. Compared with immobilized metal affinity chromatography of a general method for the analysis of phosphopeptides, the use of titania columns in the analysis permits the specific isolation of phosphopeptides in a higher yield. Using the current 2D HPLC systems, phosphopeptides were specifically isolated from nonphosphorylated peptides by the first-dimension titania column, followed by the high-speed separation of the phosphopeptides by the second-dimension monolithic column. Proteolytic digests of beta-casein were analyzed within 30 min using the comprehensive 2D HPLC system; all phosphopeptides from beta-casein could be efficiently isolated and identified by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. The comprehensive 2D HPLC system coupled with mass spectrometry will be useful for high-throughput and on-line phosphoproteome analyses.

Caseins↗

Enhanced sequence coverage in tryptic fragment analysis by two-dimensional HPLC/MS using a monolithic silica capillary column.

The HPLC/MS system, in which a monolithic silica capillary column is directly connected to an electronspray-ionization mass spectrometer, showed superior performance at high mobile phase linear velocity. A two-dimensional (2D) HPLC/MS system was established, using an ion-exchange particle-packed capillary column at the first dimension and a monolithic silica capillary column at the second dimension. In an analysis of tryptic fragments from bovine serum albumin, an 81% sequence coverage, obtained by the 2D-HPLC/MS system, increased by 23% as compared to a 1D-HPLC/MS system. This 2D-HPLC/MS system using a monolithic silica capillary column should be useful for enhancing sequence coverage of tryptic fragments in proteomics.

Amino Acid Sequence↗

Simple 2D-HPLC using a monolithic silica column for peptide separation.

Separation of peptides by fast and simple two-dimensional (2D)-HPLC was studied using a monolithic silica column as a second-dimension (2nd-D) column. Every fraction from the first column, 5 cm long (2.1 mm ID) packed with polymer-based cation exchange beads, was subjected to separation in the 2nd-D using an octadecylsilylated (C18) monolithic sillica column (4.6 mm ID, 2.5 cm). A capillary-type monolithic silica C18column (0.1 mm ID, 10 cm) was also employed as a 2nd-D column with split flow/injection. Effluentof the first dimension (1st-D) was directly loaded into an injector loop of 2nd-D HPLC. UV and MS detection were successfully carried out at high linear velocity of mobile phase at 2nd-D using flow splitting for the 4.6 mm ID 2nd-D column, or with directconnection of the capillary column to the MS interface. Two-minute fractionation inthe 1st-D, 118-second loading, and 2-second injection by the 2nd-D injector, allowed one minute for gradient separation in the 2nd-D, resulting in a maximum peak capacity of about 700 within 40 min. The use of a capillary column in solvent consumption and better MS detectability compared to a larger-sized column. This kind of fast and simple 2D-HPLC utilizing monolithic silica columns will be useful for the separation of complex mixtures in a short time.

Animals↗

How to utilize the true performance of monolithic silica columns.

Ways of utilizing the true separation efficiency of monolithic silica (MS) columns were studied. The true performance of MS columns, both regular-sized (rod-type clad with PEEK resin, 4.6 mm ID, 10 cm) and capillary sized (in 100 or 200 microm ID fused silica capillary, 25-140 cm) was evaluated by calculating the contribution of extra-column effects. HETP values of 7-9 microm were observed for solutes having retention factors (kvalues) of up to 4 for rod columns and up to 15 for a capillary column. The high permeability of MS columns allowed the use of long columns, with several connected together in the case of rod columns. Narrow-bore connectors gave good results. Peak variance caused by a column connector ranges from 50 to 70% of that caused by one rod-type column for up to three connectors or four columns in 80% methanol, but the addition of a 4th or 5th connector to add a 5th and 6th column, respectively, caused a much greater increase in peak variance, especially for long-retained solutes, which is greater than the variance caused by one rod column. Rod columns seem to show slightly lower efficiency at a pressure higher than 10 MPa or so. The use of acetonitrile-water as a mobile phase better preserved the ability of individual rod columns to generate up to 100,000 theoretical plates with 14 columns connected. Methods for eliminating extra-column effects in micro-HPLC were also studied. Split injection and on-column detection resulted in optimum performance. A long MS capillary measuring 140 cm produced 160,000 theoretical plates. The column efficiency of a capillary column was not affected by the pressure, showing advantages over the rod columns that exhibited peak broadening caused by connectors and pressure.

Chromatography, High Pressure Liquid↗