PubMed Health⌕ Search

Biomedical subjects

Hiroshi Kumagai

Publications and source records attributed to Hiroshi Kumagai.

16 recordsLinked to original sources

An immune-associated mitochondrial DNA variant with sex differences reveals a putative novel microprotein called MASL.

The use of mitochondrial wide association studies (MiWAS) to link mitochondrial DNA variants (mtSNPs) to phenotypes of interest has uncovered important connections between mitochondrial genes and human health. The recent introduction of a re-annotated mitochondrial genome that accounts for small open reading frames (sORFs) with protein coding potential suggests the existence of mitochondrial-derived microproteins, many of which remain uncharacterized. Thus, considering the re-annotated mitochondrial genome when conducting genomic analyses such as MiWAS facilitates the mapping of mtSNPs back to microprotein-encoding sORFs and uncovers interactions between mitochondrial microproteins and biological systems. Here, we employ MiWAS of venous blood samples from the Health and Retirement Study (HRS) and identify a mtSNP associated with sex-specific changes to immune composition. After accounting for re-annotation, we map the identified mtSNP back to a sORF that encodes a novel microprotein, termed MASL (Mitochondrial Associated Small d-Loop peptide). Complementary phenome-wide association studies (PheWAS) in HRS and and UK Biobank confirm interactions between this mtSNP and immune phenotypes of interest, and our targeted RNA-Seq method (mitoSNP-seq) elucidates sex-differences in gene expression and functional pathways potentially altered by this mtSNP that may be relevant to the associated microprotein. Early characterization of the MASL microprotein shows sex-differences in circulating MASL levels in human plasma, and sex-specific interactions when comparing male and female mice treated with synthesized MASL. Together, the results of this study not only contribute to our understanding of mitochondrial dynamics in immunity, but also provide early characterization of a novel mitochondrial-derived microprotein with sex-specific modulatory effects.

Genomics↗

Genome-Wide Association Study on Muscle Stiffness Identified Novel Locus for Predisposition to Muscle Strain Injury.

PURPOSE: We aimed to screen the entire genome for genetic variants associated with passive muscle stiffness, which has been suggested as a risk factor for muscle strain injury. METHODS: This genome-wide association study (GWAS) on passive muscle stiffness included 350 physically active young Japanese individuals. Three hamstring constituents were measured using ultrasound shear wave elastography. Skeletal muscle transcriptomes were compared across the genotypes of GWAS-identified variants in 48 healthy Japanese individuals. Association between GWAS-identified variants and history of muscle strain injury was examined in 1428 Japanese athletes. RESULTS: Two loci on chromosome 11 demonstrated a genome-wide significant association with passive muscle stiffness of the biceps femoris long head (rs12807854 T/C: P = 5.19 × 10 -10 , rs78405694 T/C: P = 2.09 × 10 -8 ; linear regression analysis adjusted for sex, age, and stretching exercise habits). Skeletal muscle RNA sequencing revealed significantly elevated expression of extracellular matrix-related genes in muscles carrying stiffness-increasing alleles of these variants. Among athletes, rs12807854 T/C was significantly associated with a history of muscle strain injury ( P = 0.0254; logistic regression analysis adjusted for age, sex, competitive level, and main sport). Carriers of the C allele, associated with increased muscle stiffness, exhibited a heightened risk of muscle strain injury (odds ratio = 1.62; 95% confidence interval = 1.06-2.47 per C allele increase). By contrast, rs78405694 did not show a significant association with muscle strain injury in this population. CONCLUSIONS: A novel locus associated with passive muscle stiffness and muscle strain injury was identified. Elucidating the detailed mechanisms linking the identified locus to passive muscle stiffness may lead to the development of new strategies to prevent muscle strain injuries.

Humans↗

Fine frequency tuning in sum-frequency generation of continuous-wave single-frequency coherent light at 252 nm with dual-wavelength enhancement.

Fine frequency tuning of the deep-ultraviolet single-mode coherent light at 252 nm was conducted through the PID feedback system automatically by changing the temperature of a beta-BaB(2)O(4) (BBO) crystal in a doubly resonant external cavity for the sum-frequency mixing of 373 and 780 nm light. The temperature-dependent frequency tuning rate is 19.3 MHzK(-1), which is sufficiently fine to realize the laser cooling of neutral silicon atoms because the natural width of the laser cooling transition is 28.8 MHz.

Journal Article↗

Characterization of frequency-tripled nanosecond pulsed Ti:sapphire laser injection seeded by a frequency-scanning cw Ti:sapphire laser by use of optogalvanic spectroscopy of silicon atoms.

The performance of a narrow-linewidth nanosecond pulsed deep-UV coherent light source consisting of a frequency-tripled nanosecond pulsed Ti:sapphire laser injection seeded by a frequency-scanning cw Ti:sapphire laser has been characterized by using optogalvanic spectroscopy of silicon atoms as a diagnostic. The envelope of the optogalvanic spectrum indicates the pure Doppler broadening of silicon atoms, which was estimated to be as broad as 4 GHz, without the broadening effect from the laser linewidth itself.

Journal Article↗

Line scan diffusion tensor MRI at low magnetic field strength: feasibility study of cervical spondylotic myelopathy in an early clinical stage.

PURPOSE: To implement line scan diffusion tensor MR imaging (LSDTI) on a 0.2 Tesla MR imager, and investigate the findings in the spinal cord of patients with cervical spondylotic myelopathy in an early clinical stage. MATERIALS AND METHODS: Fourteen patients with clinical symptoms of cervical myelopathy underwent LSDTI. The signal-to-noise ratio (SNR) in the spinal cord and cerebrospinal fluid (CSF) was evaluated. The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) were measured. We classified the ROIs into two groups: 1) unaffected (no clinical symptoms and no abnormality on conventional images) and 2) affected (some clinical symptoms but no abnormal signal on conventional images). Three-dimensional (3D) fiber-tracking was also studied. RESULTS: The isotropic ADC values (10(-3)mm2/sec) were 1.28 +/- 0.11 in group 1 and 1.59 +/- 0.23 in group 2. The FAs were 0.55 +/- 0.07 in group 1, and 0.47 +/- 0.11 in group 2. The ADC value in group 2 increased (P < .001, Mann-Whitney U-test) and the FA in group 2 decreased (P = 0.24) on average, compared to those in group 1. 3D fiber-tracking was successful in 64% (9/14) of the cases. CONCLUSION: LSDT images at low field strength may be a sensitive method for elucidating the structural characteristics of spinal cord pathology in vivo. However, clinical correlation and a long-term follow-up study will be needed.

Adolescent↗

Line-scan diffusion tensor MR imaging at 0.2 T: feasibility study.

PURPOSE: To investigate and measure apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values using data obtained with line-scan diffusion-weighted imaging (DWI) of human brains on a 0.2 Tesla MR imager. MATERIALS AND METHODS: Diffusion-tensor imaging (DTI) was performed on eight healthy volunteers. The signal-to-noise ratios (SNRs) of white matter and cerebrospinal fluid were measured. ADC and FA were also measured from the data obtained from all subjects. Three-dimensional corticospinal fiber tracts were reconstructed from the DT images and a qualitative evaluation was done. RESULTS: The total scan time was 52 minutes 30 seconds for 18 slices with full-tensor images covering the whole brain. The ADCs and FAs show the appropriate values, in comparison with values obtained at high field strength in previous studies. Corticospinal fibers were demonstrated more clearly on images obtained at 0.2 T than at 1.5T. CONCLUSION: DTI at low field strength may be feasible for clinical use to estimate the white matter of brain with limited coverage, which often may be sufficient.

Adult↗

Efficient sum-frequency generation of continuous-wave single-frequency coherent light at 252 nm with dual wavelength enhancement.

Highly efficient frequency conversions were conducted to obtain deep-ultraviolet single-mode coherent light by use of two-stage external cavities. A power of 154 mW at approximately 252 nm was obtained with a conversion efficiency of more than 8% by doubly resonant sum-frequency mixing of 373-nm light from the first-stage conversion and 780-nm light from a single-mode Ti:sapphire laser. The output performance of the deep-ultraviolet light source is sufficient for use in the laser cooling of neutral silicon atoms.

Journal Article↗

SEM and TEM analysis of water degradation of human dentinal collagen.

Recently several long-term studies have reported evidence of the hydrolytic degradation of collagen fibrils based on fractured surface observations after bond testing. Those studies suggested that one cause of the decline in the bond strength was the degradation of the collagen fibrils within the bonds. However, one concern has been raised that the dentinal collagen fibrils may be stable in water that does not contain oral bacteria or enzymes. Therefore, the present study aimed to clarify the micromorphological change in naked collagen fibrils after 500 days of water storage. To prepare exposed collagen fibrils, sectioned and polished human dentin surfaces were acid conditioned for 15 s with the use of two commercially available acid conditioners: All-Etch (10% phosphoric acid) and Uni-Etch (32% phosphoric acid) (Bisco, Inc.). Those specimens were stored in distilled water at 37 degrees C for 1 day (control) for 500 days. After the storage periods, the samples were examined with the use of SEM and TEM. Under SEM and TEM examination, micromorphological alterations (disarrangement of collagen web, widening the interfibrillar space, and the thinning diameter of collagen fibrils) were found in the specimens after 500 days in water.

Acid Etching, Dental↗

T1-weighted fluid-attenuated inversion recovery at low field strength: a viable alternative for T1-weighted intracranial imaging.

BACKGROUND AND PURPOSE: T1-weighted spin-echo imaging has been widely used to study anatomic detail and abnormalities of the brain; however, the image contrast of this technique is often poor, especially at low field strengths. We tested a new pulse sequence, T1-weighted fluid-attenuated inversion recovery (FLAIR), which provides good contrast between lesions, surrounding edematous tissue, and normal parenchyma at low field strengths and at acquisition times comparable to those of T1-weighted spin-echo imaging. METHODS: Thirteen patients with brain lesions underwent T1-weighted spin-echo and T1-weighted FLAIR imaging during the same imaging session. T1-weighted spin-echo and T1-weighted FLAIR images were compared on the basis of four quantitative (lesion-white matter [WM] contrast-to-noise ratio [CNR], lesion-CSF CNR, gray matter-WM CNR, and WM-CSF CNR) and three qualitative criteria (conspicuousness of lesions, image artifacts, and overall image contrast). RESULTS: CNRs obtained with T1-weighted FLAIR were comparable but statistically superior to those obtained with T1-weighted spin-echo imaging. In general, T1-weighted FLAIR and T1-weighted spin-echo imaging produced comparable image artifacts. Conspicuousness of lesions and the overall image contrast were judged to be superior on T1-weighted FLAIR images. CONCLUSION: T1-weighted FLAIR imaging may be a valuable alternative to conventional T1-weighted imaging, because the former technique offers superior image contrast at low field strengths and comparable acquisition times.

Adult↗

High-power regime of femtosecond-laser pulse propagation in silica: multiple-cone formation.

We present a numerical study of the (2+1)-dimensional propagation dynamics of femtosecond-laser pulses in silica. In particular, considered are pulses, whose power is tens to hundreds of times higher than the threshold for self-focusing. We solve the axially symmetric, extended, nonlinear Schrödinger equation for the laser electric field, including group velocity dispersion, Kerr nonlinearity, plasma formation and defocusing, self-steepening, and space-time focusing. Our simulation results reveal that the high-power pulses are split spatially, as well as temporally, several times into multiple cones during its propagation. This new structure is formed as a result of the interplay of strong Kerr self-focusing and plasma defocusing. The number of cones and their angle with respect to the propagation axis increase with incident pulse energy. The uncertainty, which may be contained in the evaluation of plasma response and band-to-band transition rate, and the pulse disturbance by modulation instability are also analyzed. Although these influence the details of the pulse propagation, they do not affect the essence of our results: the multiple-cone formation.

Journal Article↗

Optimal inversion time for acquiring flow-sensitive alternating inversion recovery images to quantify regional cerebral blood flow.

The purpose of this study was to correlate regional cerebral blood flow (rCBF) measured by I-123-IMP and flow-sensitive alternating inversion recovery (FAIR) studies with different inversion time (TI) values to find out the optimum TI that gives comparable rCBF and images on FAIR study. Nine patients with symptoms and signs of internal carotid or major cerebral arterial stenosis were enrolled in this study. Both I-123-IMP single photon emission computed tomography (SPECT) and FAIR images were acquired in all patients. Single-slice FAIR images (with different TI values) were acquired using a 1.5-T MRI unit. The rCBF was calculated from all I-123-IMP and FAIR images. Receiver operating characteristics (ROC) analysis was performed to detect hypoperfused segments on FAIR images. The rCBF calculated from FAIR and I-123-IMP studies were compared and correlated with each other. The ROC analysis showed no significant differences among the readers or TI values, but a trend of higher sensitivity, specificity, and accuracy was observed with TI of 1400 ms. The rCBF values of FAIR and I-123-IMP studies significantly correlated with each other. The FAIR images with TI value of 1400 ms gave more comparable CBF. A TI value of 1400 ms might be optimum for 1.5-T MR strength to get high quality FAIR images and comparable CBF.

Aged↗

Ferumoxides-enhanced double-echo T2-weighted MR imaging in differentiating metastases from nonsolid benign lesions of the liver.

PURPOSE: To investigate whether ferumoxides-enhanced double-echo T2-weighted magnetic resonance (MR) imaging alone can allow differentiation of metastases from benign lesions in the noncirrhotic liver. MATERIALS AND METHODS: At retrospective review of files and images, 60 lesions (22 metastases, 20 hemangiomas, and 18 cysts) were identified in 42 patients. All fast spin-echo T2-weighted MR images obtained before and after administration of ferumoxides with short (80-90 msec) and long (180-250 msec) echo times (TEs) were acquired with a 1.5-T system. Differences in lesion-to-liver signal intensity ratio between images obtained with long and short TEs were calculated. Data from all 60 lesions were entered into a receiver operating characteristic analysis. Three independent readers scored their observations of each lesion with a confidence level of 1-5. The diagnostic accuracy of each analysis method was determined by calculating the area under each reader-specific receiver operating characteristic curve. Interobserver agreement was calculated with the use of chance-corrected kappa statistics. Relative sensitivity, specificity, and accuracy of characterizing benign lesions with each method were calculated. RESULTS: Markedly low signal intensity and lesion-to-liver ratio on ferumoxides-enhanced images were observed with hemangioma. The difference of lesion-to-liver ratio between long and short TEs on ferumoxides-enhanced images was significantly different from that of unenhanced images and that of metastases or cysts. Interobserver agreement was good to excellent. Ferumoxides-enhanced images (with short and long TEs) showed significantly higher diagnostic accuracy than that of unenhanced images (with short or short and long TEs). Ferumoxides-enhanced images showed similar sensitivity, specificity, and accuracy when all images were reviewed together. CONCLUSION: Ferumoxides-enhanced T2-weighted MR images appear useful in differentiating metastases from benign (nonsolid) lesions in the liver.

Adult↗

Quantitative measurement of regional cerebral blood flow with flow-sensitive alternating inversion recovery imaging: comparison with [iodine 123]-iodoamphetamin single photon emission CT.

BACKGROUND AND PURPOSE: Flow-sensitive alternating inversion recovery (FAIR) MR imaging is a technique for depicting cerebral perfusion without contrast enhancement. Our purpose was to determine whether quantification at FAIR imaging can be used to assess regional cerebral blood flow (rCBF) in a manner similar to [iodine 123]-iodoamphetamin ((123)I-IMP) single photon emission CT (SPECT). METHODS: Nine patients with internal carotid or major cerebral arterial stenosis underwent (123)I-IMP SPECT and FAIR imaging (single section, different TIs, 1.5 T) at rest and after acetazolamide (Diamox) stress. FAIR and (123)I-IMP rCBF values were compared and correlated. Receiver operating characteristic analysis was conducted to detect hypoperfused segments on FAIR images. RESULTS: rCBF values of normally perfused segments were 41.53 and 51.91 mL/100 g/min for pre- and post-acetazolamide (123)I-IMP studies, respectively. Corresponding values for pre- and post-acetazolamide FAIR images, respectively, were 46.64 and 59.60 mL/100 g/min with a TI of 1200 milliseconds and 53.23 and 68.17 mL/100 g/min with a TI of 1400 milliseconds. (123)I-IMP and FAIR results were significantly correlated, with both pre- and post-acetazolamide images. Sensitivity (86%) in detecting hypoperfused segments was significantly higher with post-acetazolamide images (TI, 1400 milliseconds), and specificity (82-85%) and accuracy (80-82%) were higher with all pre- and post-acetazolamide images (all TIs). CONCLUSIONS: The significant correlation, high specificity and accuracy in detecting hypoperfused segments, similar increases in flow on both post-acetazolamide images, and absence of the need for contrast enhancement suggest that FAIR imaging, like nuclear medicine study, is complementary to routine MR imaging in the assessment of cerebral perfusion.

Acetazolamide↗

[Line scan diffusion weighted imaging (LSDI) on 0.2 Tesla MRI of the normal cervical cord in vivo: preliminary study].

Diffusion weighted imaging(DWI) has been widely performed in the brain. However, DWI of the spinal cord is rarely performed because of technical and physiologic problems. Line scan diffusion weighted imaging(LSDI) is spin-echo based and relatively insensitive to susceptibility artifacts. We calculated the apparent diffusion coefficient(ADC) values of the normal cervical spinal cord by LSDI on a 0.2 Tesla MR imager and compared the ADC values with those from 1.5 Tesla MRI previously reported in the literature. The ADC values were adequate, and LSDI on 0.2 Tesla MRI is expected to become a useful tool for clinical application.

Adult↗

MR-guided intravascular catheter manipulation: feasibility of both active and passive tracking in experimental study and initial clinical applications.

PURPOSE: To evaluate clinically the feasibility and usefulness of MR-guided intravascular procedures with either active or passive tracking. METHODS: With an active MR tacking system and a 0.2 Tesla open MR imager, real-time and biplane displays of positions of a receive-only coil at the tip of catheters were obtained. For passive tracking, 4 Fr catheters with suitable susceptibility for passive tracking were used. Passive tracking with a 1.5 Tesla MR imager could be performed with parameters of TR 15-50 msec, TE 2.2-2.7 msec, and FA 30 degrees. The temperature of each tracking catheter was monitored in vitro. Clinical trials were performed on six patients (three each). The catheter was introduced to the superior mesenteric artery (SMA) under MR guidance by active or passive tracking to perform MR imaging during arterial portography. RESULTS: The temperature increased minimally. In humans, the SMA and celiac artery could be easily introduced on active tracking. MR-guided manipulation of catheters by active or passive tracking in the model and in dogs' vessels was very successful. Introduction of the catheter into the SMA was successful in two cases of active tracking and in all cases of passive tracking. CONCLUSION: The MR-guided intravascular manipulation of catheters by active or passive tracking may be a clinically feasible method.

Catheterization, Peripheral↗