Short communication performance of octadecylsilylated monolithic silica capillary columns of 530 microm inner diameter in HPLC.

Monolithic silica capillary columns were successfully prepared in a fused silica capillary of 530 microm inner diameter and evaluated in HPLC after octadecylsilylation (ODS). Their efficiency and permeability were compared with those of columns pakked with 5-microm and 3-microm ODS-silica particles. The monolithic silica columns having different domain sizes (combined size of through-pore and skeleton) showed 2.5-4.0-times higher permeability (K= 5.2-8.4 x 10(-14) m2) than capillary columns packed with 3-mm particles, while giving similar column efficiency. The monolithic silica capillary columns gave a plate height of about 11-13 microm, or 11 200-13 400 theoretical plates/150 mm column length, in 80% methanol at a linear mobile phase velocity of 1.0 mm/s. The monolithic column having a smaller domain size showed higher column efficiency and higher pressure drop, although the monolithic column with a larger domain size showed better overall column performance, or smaller separation impedance (E value). The larger-diameter (530 microm id) monolithic silica capillary column afforded a good peak shape in gradient elution of proteins at a flow rate of up to 100 microL/min and an injection volume of up to 10 microL.

Journal Article↗

Silica monolithic membrane as separation medium. Summable property of different membranes for high-performance liquid chromatographic separation.

We studied an applicability of a silica monolithic membrane as separation medium for high-performance liquid chromatography (HPLC). We prepared porous monolithic silica membranes having a three-dimensional network structure to cut and shape into a membrane separation medium. We evaluated chromatographic properties of a variety of solutes using a column containing the membranes with HPLC to elucidate summable property of the membrane separation media. In addition, we made brief study on separation of HbA1c in whole blood with the stacked" membranes having different surface characteristics in one column, which is a membrane column. We confirmed that the membrane column was able to separate HbA1c from other matrix in whole blood to some extent, and it also had an excellent ability for hydrophobic and ion exchange adsorption.

Chromatography, High Pressure Liquid↗

Development of miniaturized multi-channel high-performance liquid chromatography for high-throughput analysis.

We have developed miniaturized multi-channel high-performance liquid chromatography (HPLC) system. With this system, we can simultaneously separate multiple samples, using a single high-pressure gradient pump, a chip-based sample injection unit, a monolithic silica capillary column array, and a multi-channel UV detection unit based on fiber optics. The injection unit has a simplified structure composed of brass housing and a quartz microchip having microchannels and access ports, which enable a direct injection of sample to multi-channel by commercial multichannel micropipette. Moreover, that possesses a function of microvalve, and on-chip definition of sample injection plugs achieved with a cross channel injection method, providing each column of monolithic silica capillary array. The substances in channels were simultaneously detected with UV having multiple cells. Standard samples were analyzed for characterizing newly developed system, and sharp peaks were obtained with reproducibility data of < 0.9% (R.S.D.). Analysis of tryptic digestion of casein was also employed. These results show that the novel multi-channel HPLC system has the benefits for the high-throughput analysis in the post-genomic analysis/combinatorial chemistry.

Chromatography, High Pressure Liquid↗

Development of a monolithic silica extraction tip for the analysis of proteins.

In proteomics, pre-treatment of sample is the most important procedure to remove the matrix for interfacing with mass spectrometry (MS). Additionally, for the samples with low concentration, the process of pre-concentration is required before MS analysis. We have newly developed solid-phase extraction (SPE) tool with pipette-tip shape for purification of bio-samples of various characteristics, utilizing monolithic silica gel as medium. The monolithic silica surface was modified with a C18 phase or coated with titania phase. A C18-bonded tip and a non-modified tip were used for sample concentration, desaltination and removal of detergents from sample. A titania-coated tip was also applied for purification and concentration of phosphorylated peptides. This novel pre-treatment method using monolithic silica extraction tip is much effective and suitable for protein analysis.

Chromatography, High Pressure Liquid↗

Microanalysis for MDR1 ATPase by high-performance liquid chromatography with a titanium dioxide column.

MDR1 is clinically important because it is involved in multidrug resistance of cancer cells and affects the pharmacokinetics of various drugs. Because MDR1 harnesses adenosine 5'-triphosphate (ATP) hydrolysis for transporting drugs, examining the effect on ATPase activity is imperative for understanding the interactions between drugs and MDR1. However, conventional assay systems for ATPase activity are not sensitive enough for screening drugs using purified MDR1. Here we report a novel method to measure ATPase activity of MDR1 using high-performance liquid chromatography equipped with a titanium dioxide column. The amount of adenosine 5'-diphosphate (ADP) produced by the ATPase reaction was determined within 2 min with a titanium dioxide column (4.6 mm ID x 100 mm). The relationship between ADP amount and chromatogram peak area was linear from 5 pmol to 10 nmol. This method made it possible to reduce the amount of purified MDR1 required for a reaction to 0.5 ng, about 1/20th of the conventional colorimetric inorganic phosphate detection assay. This method is sensitive enough to detect any subtle changes in ATPase activity of MDR1 induced by drugs and can be applied to measure ATPase activity of any protein.

ATP Binding Cassette Transporter, Subfamily B, Mem↗

Simple and comprehensive two-dimensional reversed-phase HPLC using monolithic silica columns.

Simple and comprehensive two-dimensional (2D)-HPLC was studied in a reversed-phase mode using monolithic silica columns for second-dimension (2nd-D) separation. Every fraction from the first column, 15 cm long (4.6-mm i.d.), packed with fluoroalkylsilyl-bonded (FR) silica particles, was subjected to the separation in the 2nd-D using one or two octadecylsilylated (C(18)) monolithic silica columns (4.6-mm i.d., 3 cm). Monolithic silica columns in the 2nd-D were eluted at a flow rate of up to 10 mL/min with separation time of 30 s that meets the fractionation every 15-30 s at the first dimension (1st-D) operated at a flow rate of 0.4-0.8 mL/min. Three cases were studied. (1) In the simplest scheme of 2D-HPLC, effluent of the 1st-D was directly loaded into an injector loop of 2nd-D HPLC for 28 s, and 2 s was allowed for injection. (2) Two six-port valves each having a sample loop were used to hold the effluent of the 1st-D alternately for 30 s for one 2nd-D column to effect comprehensive 2D-HPLC without the loss of 1st-D effluent. (3) Two monolithic silica columns were used for 2nd-D by using a switching valve and two sets of 2nd-D chromatographs separating each fraction of the 1st-D effluent with the two 2nd-D columns alternately. In this case, two columns of the same stationary phase (C(18)) or different phases, C(18) and (pentabromobenzyloxy)propylsilyl-bonded (PBB), could be employed at the 2nd-D, although the latter needed two complementary runs. The systems produced peak capacity of approximately 1000 in approximately 60 min in cases 1 and 2 and in approximately 30 min in case 3. The three stationary phases, FR, C(18), and PBB, showed widely different selectivity from each other, making 2D separations possible. The simple and comprehensive 2D-HPLC utilizes the stability and high efficiency at high linear velocities of monolithic silica columns.

Journal Article↗

Simple 2D-HPLC using a monolithic silica column for peptide separation.

Separation of peptides by fast and simple two-dimensional (2D)-HPLC was studied using a monolithic silica column as a second-dimension (2nd-D) column. Every fraction from the first column, 5 cm long (2.1 mm ID) packed with polymer-based cation exchange beads, was subjected to separation in the 2nd-D using an octadecylsilylated (C18) monolithic sillica column (4.6 mm ID, 2.5 cm). A capillary-type monolithic silica C18column (0.1 mm ID, 10 cm) was also employed as a 2nd-D column with split flow/injection. Effluentof the first dimension (1st-D) was directly loaded into an injector loop of 2nd-D HPLC. UV and MS detection were successfully carried out at high linear velocity of mobile phase at 2nd-D using flow splitting for the 4.6 mm ID 2nd-D column, or with directconnection of the capillary column to the MS interface. Two-minute fractionation inthe 1st-D, 118-second loading, and 2-second injection by the 2nd-D injector, allowed one minute for gradient separation in the 2nd-D, resulting in a maximum peak capacity of about 700 within 40 min. The use of a capillary column in solvent consumption and better MS detectability compared to a larger-sized column. This kind of fast and simple 2D-HPLC utilizing monolithic silica columns will be useful for the separation of complex mixtures in a short time.

Animals↗

Polydimethylsiloxane connection for quartz microchips in a high-pressure system.

An interconnecting technique, the "PDMS connection method", for quartz microchips in a high-pressure system is presented. The connection between quartz microchips is an essential technology for modular microfluidic devices, such as microchip-HPLC. PDMS was applied to the seal material, being spread on the seal side of the chips, and set into the metal housing. The characteristics of the PDMS connection method concerning pressure resistance and the extension of the peak were examined. The experimental results showed a good seal at 5 MPa, which seem to be sufficient for realizing microchip-HPLC utilizing a monolithic silica capillary column as a separation medium. The influence of the extra column effect on chromatographic separation was almost the same as in the case using a commercial union fitting. In addition, the PDMS connection enabled the detachability of chip-based modules with user-friendliness. Our experimental findings suggest that the novel PDMS connection method can possibly be applied as a generic technology in high-pressure microTAS.

Journal Article↗

Monolithic silica column for in-tube solid-phase microextraction coupled to high-performance liquid chromatography.

In-tube solid-phase microextraction (SPME) has successfully been coupled to capillary LC, and further an automated in-tube SPME system has been developed using a commercially available HPLC auto-sampler. However, an open tubular capillary column with a thick film of polymer (stationary phase) is unfavorable because the ratio of the surface area of coating layer contacted with sample solution to the volume of the capillary column is insufficient for mass transfer. A highly efficient SPME column is. therefore, required. We introduced a C18-bonded monolithic capillary column that was used for in-tube SPME. The column consisted of continuous porous silica having a double-pore structure. Both the through-pore and the meso-pore were optimized for in-tube SPME, and the optimized capillary column was connected to an HPLC injection valve for characterization. The results demonstrated that the pre-concentration efficiency is excellent compared with the conventional in-tube SPME. The novel method for both introduction and concentration of the samples was effective. satisfactory and suitable for use in the SPME medium.

Chromatography, High Pressure Liquid↗

Monolithic silica columns for high-efficiency chromatographic separations.

Studies on the structural and chromatographic properties of monolithic silica columns were reviewed. Monolithic silica columns prepared from tetraalkoxysilane by a sol-gel method showed high efficiency and high permeability on the basis of the small-sized silica skeletons, large-sized through-pores, and resulting through-pore size/skeleton size ratios much larger than those found in a particle-packed column.

Chromatography, Liquid↗

Monolithic silica columns with various skeleton sizes and through-pore sizes for capillary liquid chromatography.

Reduction of through-pore size and skeleton size of a monolithic silica column was attempted to provide high separation efficiency in a short time. Monolithic silica columns were prepared to have various sizes of skeletons (approximately 1-2 microm) and through-pores (approximately 2-8 microm) in a fused-silica capillary (50-200 microm I.D.). The columns were evaluated in HPLC after derivatization to C18 phase. It was possible to prepare monolithic silica structures in capillaries of up to 200 microm I.D. from a mixture of tetramethoxysilane and methyltrimethoxysilane. As expected, a monolithic silica column with smaller domain size showed higher column efficiency and higher pressure drop. High external porosity (> 80%) and large through-pores resulted in high permeability (K = 8 x 10(-14) -1.3 x 10(-12) m2) that was 2-30 times higher than that of a column packed with 5-mirom silica particles. The monolithic silica columns prepared in capillaries produced a plate height of about 8-12 microm with an 80% aqueous acetonitrile mobile phase at a linear velocity of 1 mm/s. Separation impedance, E, was found to be as low as 100 under optimum conditions, a value about an order of magnitude lower than reported for conventional columns packed with 5-microm particles. Although a column with smaller domain size generally resulted in higher separation impedance and the lower total performance, the monolithic silica columns showed performance beyond the limit of conventional particle-packed columns under pressure-driven conditions.

Chromatography, Liquid↗

Monolithic silica columns for high-efficiency separations by high-performance liquid chromatography.

Generation of a large number of theoretical plates was attempted by capillary HPLC. Monolithic silica columns having small skeletons (ca. 2 microm) and large through-pores (ca. 8 microm) were prepared by a sol-gel method in a fused-silica capillary (50 microm I.D.), and derivatized to C18 phase by on-column reaction. High external porosity (>80%) and large through-pores resulted in high permeability (K= 1.2 x 10(-2) m2). The monolithic silica column in the capillary produced a plate height of about 12 microm in 80% acetonitrile at a linear velocity of 1 mm/s. Separation impedance, E value, was found to be as low as 200, that was about an order of magnitude lower than reported values for conventional columns packed with 5 microm particles. Reproducibility of preparation within +/- 15% was obtained for column efficiency and for pressure drop. It was possible to generate 100,000 plates by using a 130-cm column at very low pressure (<7 kg/cm2). A considerable decrease in column efficiency was observed at high linear velocity, and for solutes with large retention factors due to the slow mobile-phase mass transfer in the large through-pores. The monolithic silica columns, however, showed performance beyond the limit of conventional particle-packed columns in HPLC under favorable conditions.

Chromatography, High Pressure Liquid↗