PubMed Health⌕ Search

Biomedical subjects

Hiroyuki Kabasawa

Publications and source records attributed to Hiroyuki Kabasawa.

20 records · Page 2Linked to original sources

Periodically rotated overlapping parallel lines with enhanced reconstruction-based diffusion tensor imaging. Comparison with echo planar imaging-based diffusion tensor imaging.

OBJECTIVE: To evaluate diffusion tensor imaging (DTI) based on periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) compared with DTI based on single-shot echo planar imaging (EPI). METHODS: Diffusion tensor data were acquired with PROPELLER (PROPELLER-DTI, 3 NEX), EPI (EPI-DTI2, 16 NEX) with the same acquisition time (11.4 minutes) and with EPI (EPI-DTI1, number of excitations = 4) with a shorter acquisition time (2.8 minutes). Regions of interest were set in the genu and splenium of the corpus callosum, as determined on T2-weighted fast spin echo images and fractional anisotropy (FA) maps, separately. Two neuroradiologists visually evaluated image distortion and quality in the supra- and infratentorial structures. RESULTS: In the genu, standard deviation determined by respective FA maps was decreased in order of PROPELLER-DTI, EPI-DTI1, and EPI-DTI2. Both EPI-DTI sequences were quantitatively superior in the splenium, but PROPELLER-DTI was less distorted. CONCLUSION: Periodically rotated overlapping parallel lines with enhanced reconstruction-DTI could become a complementary tool when qualitatively evaluating seriously distorted structures.

Adult↗

Two-dimensional magnetic resonance digital subtraction angiography using array spatial sensitivity encoding techniques in the assessment of intracranial hemodynamics.

OBJECTIVE: Array spatial sensitivity encoding techniques (ASSET) were employed to improve the temporal resolution of two-dimensional (2D) thick-slice contrast-enhanced magnetic resonance digital subtraction angiography (MRDSA). METHODS: 2D MRDSA using ASSET was performed in 28 patients via fast spoiled gradient-echo sequence (TR/TE 5.4/1.5 ms; FA 60; FOV 24x24 cm; matrix size 256x256; slicethickness 50-70 mm), followed by a bolus injection of gadolinium chelate and subsequent saline flush, for 40 seconds on a sagittal plane. Images were evaluated for visualization of normal intracranial vessels and brain lesions utilizing a three-point scale; additionally, in 10 of the 28 patients, results were compared with those of conventional 2D MRDSA. RESULTS: 2D MRDSA using ASSET, which improved temporal resolution from 1.45 to 0.77 seconds, displayed image quality comparable to that of conventional 2D MRDSA. Moreover, this technique afforded superior detectability with respect to early venous filling in patients with arteriovenous malformations (AVMs). CONCLUSION: ASSET improves the temporal resolution of 2D MRDSA without compromising spatial resolution.

Brain Neoplasms↗