10 recordsLinked to original sources

Outbreaks of multidrug-resistant Pseudomonas aeruginosa in community hospitals in Japan.

We previously reported an outbreak in a neurosurgery ward of catheter-associated urinary tract infection with multidrug-resistant (MDR) Pseudomonas aeruginosa strain IMCJ2.S1, carrying the 6'-N-aminoglycoside acetyltransferase gene [aac(6')-Iae]. For further epidemiologic studies, 214 clinical isolates of MDR P. aeruginosa showing resistance to imipenem (MIC >or= 16 microg/ml), amikacin (MIC >or= 64 microg/ml), and ciprofloxacin (MIC >or= 4 microg/ml) were collected from 13 hospitals in the same prefecture in Japan. We also collected 70 clinical isolates of P. aeruginosa that were sensitive to one or more of these antibiotics and compared their characteristics with those of the MDR P. aeruginosa isolates. Of the 214 MDR P. aeruginosa isolates, 212 (99%) were serotype O11. We developed a loop-mediated isothermal amplification (LAMP) assay and a slide agglutination test for detection of the aac(6')-Iae gene and the AAC(6')-Iae protein, respectively. Of the 212 MDR P. aeruginosa isolates, 212 (100%) and 207 (98%) were positive in the LAMP assay and in the agglutination test, respectively. Mutations of gyrA and parC genes resulting in amino acid substitutions were detected in 213 of the 214 MDR P. aeruginosa isolates (99%). Of the 214 MDR P. aeruginosa isolates, 212 showed pulsed-field gel electrophoresis patterns with >or=70% similarity to that of IMCJ2.S1 and 83 showed a pattern identical to that of IMCJ2.S1, indicating that clonal expansion of MDR P. aeruginosa occurred in community hospitals in this area. The methods developed in this study to detect aac(6')-Iae were rapid and effective in diagnosing infections caused by various MDR P. aeruginosa clones.

Acetyltransferases↗

Evaluation of the BD Phoenix SMIC/ID, a new streptococci identification and antimicrobial susceptibility panel, for potential routine use in a university-based clinical microbiology laboratory.

We evaluated the new BD Phoenix automated microbiology system (Becton Dickinson Diagnostic Systems, Sparks, MD) SMIC/ID-4 panel for routine identification (ID) and antimicrobial susceptibility testing (AST) of streptococci in a university-based laboratory. Clinical isolates of Streptococcus pneumoniae (n = 92), Streptococcus pyogenes (n = 24), and Streptococcus agalactiae (n = 10) were collected, and comparisons were made with the routine manual methods used in our microbiology laboratory for ID and susceptibility testing. ID concordance with manual methods was 85.9%, 95.8%, and 90.0% for S. pneumoniae, S. pyogenes, and S. agalactiae, respectively. With respect to AST concordance for S. pneumoniae and beta-hemolytic streptococci (S. pyogenes and S. agalactiae) using Phoenix and standard broth microdilution panels, overall essential agreement was 93.0% and 97.5%, respectively, whereas overall category agreement was 92.4% and 98.9%, respectively. Major and minor error rates for S. pneumoniae and beta-hemolytic streptococci were 0.5% and 0.3%, and 7.1% and 0.8%, respectively. Very major errors were not observed in this study. Mean time for ID and AST test completion was 13.6 +/- 1.6, 10.7 +/- 2.4, and 11.2 +/- 2.3 h for S. pneumoniae, S. pyogenes, and S. agalactiae, respectively. We have demonstrated that Phoenix ID results show high agreement with manual ID and that AST performance was equivalent to standard broth microdilution in less time.

Anti-Bacterial Agents↗

Assessment of RAISUS, a novel system for identification and antimicrobial susceptibility testing for enterococci.

RAISUS, a system developed by Nissui Pharmaceutical (Tokyo, Japan), is a novel fully automated system for rapid identification and antimicrobial susceptibility testing. The aim of this study was to compare RAISUS with VITEK systems and microdilution tests based on the National Committee for Clinical Laboratory Standards, with regard to the identification and susceptibility of 64 enterococci. The agreement rate between RAISUS and VITEK was 98.4% (63/64) for bacterial identification. One strain was identified as E. faecalis by RAISUS, but as E. faecium by VITEK. Regarding susceptibility tests, the range of essential agreement and agreement in clinical categories for RAISUS and VITEK ranged from 70.3% to 95.3% and from 68.8% to 96.9%, respectively. Results of antimicrobial susceptibility testing for vancomycin (VAN) showed very major, major, and minor errors in 0%, 3.1% (2/64), and 0%, respectively. RAISUS could provide reports of detection of VAN-resistant enterococci (VRE) within 5 h by using fluorogenic substances and redox. In conclusion, RAISUS could be useful in a clinical setting because it allows rapid identification of enterococci and the potential ability to detect VRE more promptly than the VITEK system.

Bacterial Typing Techniques↗

Validation of low-temperature steam with formaldehyde sterilization for endoscopes, using validation device.

BACKGROUND: Validation of sterilization is an important step before clinical use of medical equipment. Adequate validation of sterilization of the endoscope has not been reported. One reason for this is the lack of suitable devices for validation. METHODS: The VDES (validation device for endoscope sterilization; Olympus prototype model, Olympus, Tokyo, Japan) was designed in two types (type A and type B) and resembles gastroscopes and duodenoscopes, respectively. Each type consists of inner and outer tubing and a central capsule containing a biological indicator. The device was designed to examine the effectiveness of low-temperature sterilizers, such as ethylene oxide gas, hydrogen peroxide gas plasma, and low-temperature steam with formaldehyde (LTSF) sterilizer. The aim of this study was to validate the sterilization of GI endoscopes by the LTSF sterilizer. Sterilization was assessed using both types of VDES after a 60-min application of LTSF. RESULTS: Culture of the biological indicator confirmed the complete eradication of the bacteria in a total of 10 experiments with each type of VDES after LTSF sterilization. CONCLUSIONS: Our results confirm that the LTSF sterilizer may sterilize endoscopes currently distributed by Olympus. Commercialization of VDES will make it possible to evaluate the reliability of sterilization when it is set in the sterilization device with endoscopes.

Bacillaceae↗

A comparative study of ethylene oxide gas, hydrogen peroxide gas plasma, and low-temperature steam formaldehyde sterilization.

OBJECTIVE: To compare the efficacies of ethylene oxide gas (EOG), hydrogen peroxide gas plasma (PLASMA), and low-temperature steam formaldehyde (LTSF) sterilization methods. METHODS: The efficacies of EOG, PLASMA, and LTSF sterilization were tested using metal and plastic plates, common medical instruments, and three process challenge devices with narrow lumens. All items were contaminated with Bacillus stearothermophilus spores or used a standard biological indicator. RESULTS: EOG and LTSF demonstrated effective killing of B. stearothermophilus spores, with or without serum, on plates, on instruments, and in process challenge devices. PLASMA failed to adequately sterilize materials on multiple trials in several experiments, including two of three plates, two of three instruments, and all process challenge devices. CONCLUSIONS: Our results suggest that PLASMA sterilization may be unsuccessful under certain conditions, particularly when used for items with complex shapes and narrow lumens. Alternatively, LTSF sterilization demonstrates excellent efficacy and is comparable to EOG sterilization. LTSF could potentially act as a substitute if EOG becomes unavailable due to environmental concerns.

Equipment and Supplies↗

[In vitro susceptibilites to levofloxacin and various antibacterial agents of 11,475 clinical isolates obtained from 52 centers in 2002].

The susceptibilities of bacteria to fluoroquinolones (FQs), especially levofloxacin, and other antimicrobial agents were investigated using 11,475 clinical isolates collected in Japan during 2002. Methicillin susceptible staphylococci, Streptococcus pyogenes, Streptococcus pneumoniae, Moraxella catarrhalis, the family of Enterobactericeae, Haemophilus influenzae and Acinetobacter spp. exhibited stable and high susceptibilities to FQs. The rate of FQs-resistant MRSA was 80 approximately 90%, being markedly higher than that of FQs-resistant MSSA. The FQs-resistance rate of MRCNS was also higher than that of MSCNS, however, it was lower than that of MRSA. No FQs-resistant clinical isolates of Salmonella spp. were detected in any of the surveys. Thirteen of Escherichai coli 696 isolates, 8 of Klebsiella pneumoniae 630 isolates and 33 of Proteus mirabilis 373 isolates produced extended-spectrum beta-lactamase (ESBL), furthermore 6 of 13 in E. coli, 1 of 8 in K. pneumoniae and 14 of 31 ESBL-producing isolates, and in P. mirabilis were FQs resistant. Attention should be focused in the future on the emergence of ESBL in relation to FQs resistance. The rate of FQs-resistant P. aeruginosa isolated from urinary tract infection (UTI) was 40 approximately 60%, while 15 approximately 25% of isolates from respiratory tract infection (RTI) were resistant. IMP-1 type metallo beta-lactamase producing organisms were found in 49 of P. aeruginosa 1,095 isolates, 7 of S. marcescens 586 isolates and 4 of Acinetobacter spp. 474 isolates, respectively. Glycopeptide-resistant enterococci or S. aureus was not found.

Anti-Bacterial Agents↗

[Roles of Department of Clinical Laboratory in infection control].

The Department of Clinical Laboratory plays an important role in the hospital and has much information about patients and pathogens. Laboratory data are essential to support clinical physicians who diagnose and treat patients. For nosocomial infections, laboratory-based surveillance is recognized as essential to confirm outbreaks. Therefore, the role of the Department of Clinical Laboratory is very important in infection control. In Tohoku University Hospital, we have an Infection Control Unit located in the Department of Clinical Laboratory. The core role of the Infection Control Unit is diagnosis, treatment and preventative healthcare associated with infections. The Infection Control Team (ICT) performs rounds in the hospital (The ICT members are ICN, ICD, a microbiological technologist and a dietician), consultations about clinical cases, infection control, and organize the regional infection control network, "Miyagi Infection Control Network". The ICT rounds are performed once a week in two wards, and two times a year for one ward. The consultations are an important role of the ICD, and concern clinical infection cases and infection control in our hospital and the other regional hospitals, and produce advice on appropriate clinical information. The regional network is important for the collection of information about the pathogens and the susceptibility of antimicrobial agents in the region. "Miyagi Infection Control Network" has held a forum 5 times a year from 1999, and 300-400 healthcare workers join the forum and discuss infection control.

Clinical Laboratory Information Systems↗

Drug-recommendation system for patients with infectious diseases.

We developed a decision support system that helps doctors select appropriate first-line drugs. The system classifies patients' abilities to protect themselves from infectious diseases as a risk level for infection. In an evaluation of the prototype system, the risk level it determined correlated with the decisions of specialists. The system is very effective and convenient for doctors to use.

Communicable Diseases↗

Efficacy of amikacin combinations for nocardiosis.

We isolated five bacterial strains from patients diagnosed as having nocardiosis. Bacterial species were identified based on the similarities in the nucleotide sequences of 16S ribosomal RNAs. Three of the five strains were identified as Nocardia asteroids, but unexpectedly other two were Streptomyces hygroscopicus and Rothia dentocariosa. The latter two species are not members of the family Nocardiaceae. We investigated the susceptibilities of these five strains to the following nine antimicrobial agents: trimethoprim/sulfamethoxazole (TMP/SMX), minocycline (MINO), erythromycin (EM), amikacin (AMK), cefotaxime (CTX), faropenem (FRPM), imipenem (IPM), ciprofloxacin (CPFX), and sparfloxacin (SPFX). The minimum inhibitory concentration (MIC) ranges (mg/ml) were as follows: TMP-SMX, 4- > 32; MINO, 0.125-8; EM, < or = 0.016- > 32; AMK, 1-2; CTX, 0.063- > 32; FRPM, 0.063-16; IPM, 0.125-2; CPFX, 4-32; and SPFX, 0.5-16. Moreover, the synergistic effects of AMK in combination with each of TMP-SMX, MINO, EM, CTX, IPM, and SPFX were investigated by checkerboard synergy testing. No antagonism was recognized for the three N. asteroides strains. Synergistic and additive effects were observed for the combinations of AMK with CTX, IPM, or SPFX.

Adult↗

[Activities of antimicrobial agents against 8,474 clinical isolates obtained from 37 medical institutions during 2000 in Japan].

A survey was conducted to determine the antimicrobial activity of fluoroquinolones and other antimicrobial agents against 8,474 clinical isolates obtained from 37 Japanese medical institutions in 2000. A total of 25 antimicrobial agents were used, comprising 4 fluoroquinolones, 13 beta-lactams, minocycline, chloramphenicol, clarithromycin, azithromycin, gentamicin, amikacin, sulfamethoxazole-trimethoprim, and vancomycin. A high resistance rate of over 85% against fluoroquinolones was exhibited by methicillin-resistant Staphylococcus aureus (MRSA) and Enterococcus faecium. Isolates showing resistance to fluoroquinolones among methicillin-resistant coagulase-negative Staphylococci, Enterococcus faecalis, and Pseudomonas aeruginosa from UTI accounted for 30-60%. However, many of the common pathogens were still susceptible to fluoroquinolones, such as Streptococcus pneumoniae (including penicillin-resistant isolates), Streptococcus pyogenes, methicillin-susceptible S. aureus (MSSA), methicillin-susceptible coagulase-negative Staphylococci, Moraxella catarrhalis, the Enterobacteriaceae family, and Haemophilus influenzae (including ampicillin-resistant isolates). About 85% of P. aeruginosa isolated from RTI were susceptible to fluoroquinolones. In conclusion, this survey of sensitivity to antimicrobial agents clearly indicated trend for increasing resistance to fluoroquinolones among MRSA, Enterococci, and P. aeruginosa isolated from UTI, although fluoroquinolones are still effective against other organisms and P. aeruginosa from RTI as has been demonstrated in previous studies.

Anti-Bacterial Agents↗