PubMed Health⌕ Search

Biomedical subjects

Hiroyuki Ohnishi

Publications and source records attributed to Hiroyuki Ohnishi.

17 recordsLinked to original sources

Characterization and morphology of atherosclerotic plaque of coronary arteries: utility of electron-beam tomography to detect non-calcified plaque: a comparison with conventional coronary angiography and intravascular ultrasound.

BACKGROUND: Electron-beam tomography (EBT) may provide useful information about characterization and morphology of atherosclerotic plaque of coronary arteries. MATERIALS AND METHODS: Twenty-six subjects (20 male, 6 female) with suspected coronary heart disease had two routine (r) and one enhanced (e) EBT scans to detect non-calcified plaque (NCP) in the coronary arterial lumen, and were compared with conventional coronary angiograms (CAG) and intravascular ultrasound (IVUS). RESULTS: Three had the sites, which did not have high CT values suggesting calcification in rEBT, nor which was not enhanced by contrast material in eEBT. One had the site with positive CT values that were supposed to be the proliferation intima or organized thrombus and at the corresponding site mixed plaque was observed in the IVUS image. The other two had the site with negative CT values that were supposed to be fat tissue with significant stenosis in CAG. We also made the cross-sectional images of the vessel and the morphology of the NCP, which projected into the lumen, could be evaluated. CONCLUSIONS: We could detect the NCP, differentiate fat tissue from soft tissue and evaluate the morphology of the plaque in EBT.

Aged↗

Aortic dissection late after aortic valve replacement.

We experienced 3 cases of an aortic dissection occurring late after an aortic valve replacement, and successfully treated by an aortic root replacement. An aortic dissection involving the ascending aorta can develop late after an aortic valve replacement, and such an occurrence is associated with a high mortality and morbidity. The development of effective surgical strategies at the initial aortic valve surgery, strict control of blood pressure after aortic valve replacement, serial evaluations of aortic size, and the prophylactic replacement of the ascending aorta for patients with aortic dilatation after aortic valve replacement, all play clinically important roles in preventing an aortic dissection after aortic valve replacement. When an aortic dissection occurs in patients with a previous aortic valve replacement, an aortic root replacement should be performed in order to avoid leaving the fragile diseased aortic wall including the sinus of Valsalva.

Adult↗

A safer technique of aortic root replacement after aortic valve replacement.

Aortic root replacement after aortic valve replacement (AVR) is often complicated by bleeding around the aortic root, which increases the risk of morbidity and mortality, making it a technically challenging procedure. We describe a new technique of aortic root replacement designed to minimize bleeding around the aortic root. This surgical technique focuses on safe dissection and exposure of the aortic root to avoid inadvertent entry into the right atrium or right ventricle; on modifying the proximal anastomosis of the graft to the aortic annulus; and on performing a coronary artery reimplantation that achieves complete hemostasis at the suture lines. We performed aortic root replacement after AVR in four patients over a 4-year period, without encountering any bleeding around the aortic root.

Adult↗

Papillary fibroelastoma of the tricuspid valve.

A 72-year-old male patient was admitted with chest oppression. Echocardiography disclosed a mobile tumor which was located on the atrial side of the tricuspid valve. Neither tricuspid obstruction nor regurgitation was observed. The mobility and the size, 20 mm in diameter, of the tumor indicated the need to perform surgical treatment. Through a right atriotomy, the tumor with multiple papillary fronds was found on the basal zone of the anterior leaflet. A resection of the tumor and tricuspid valvuloplasty with a partial annular reconstruction were performed. A pathological examination confirmed papillary fibroelastoma. He had an uneventful recovery, and postoperative echocardiography detected neither any residual tumor nor tricuspid regurgitation. In conclusion, it is reasonable to state that echocardiography is useful for detecting cardiac tumors, and a surgical resection is indicated for a mobile or large papillary fibroelastoma even when it is located on the right side of the heart.

Aged↗

Inhibition of cell proliferation by nobiletin, a dietary phytochemical, associated with apoptosis and characteristic gene expression, but lack of effect on early rat hepatocarcinogenesis in vivo.

Dietary phytochemicals can inhibit the development of certain types of tumors. We here investigated the effects of nobiletin (Nob), garcinol (Gar), auraptene (Aur), beta-cryptoxanthin- and hesperidine-rich pulp (CHRP) and 1,1'-acetoxychavicol acetate (ACA) on hepatocarcinogenesis in a rat medium-term liver bioassay, and also examined their influence on cell proliferation, cell cycle kinetics, apoptosis and cell invasion of rat and human hepatocellular carcinoma (HCC) cells, MH1C1 and HepG2, respectively. While there were no obvious suppressive effects on the development of putative preneoplastic liver lesions, inhibition of hepatocarcinoma cell proliferation was evident in the Nob group. Nob also caused G2/M cell cycle arrest and apoptosis. Microarray analysis identified a set of genes specifically regulated by Nob, and these are likely to be involved in the observed growth suppression of HCC cells. These results suggest that phytochemicals might have chemopreventive potential in late stages of hepatocarcinogenesis.

Animals↗

The roles of vascular smooth muscle cells in the aortic wall thinness under prolonged continuous flow left heart bypass.

Aortic wall thinness was one of the most characteristic changes observed in experimental animals under prolonged continuous flow left heart bypass. The goal of this study was to determine the roles of smooth muscle cells in the vascular remodeling process in cases demonstrating aortic wall thinness under prolonged continuous flow left heart bypass. The aortic samples from three goats in which continuous flow left heart bypass was performed were subjected to histological and immunohistochemical analyses. After 4 weeks of observation, the pulse pressure in the goats under the continuous flow left heart bypass was clearly lower than that in the normal healthy goats. The aortic walls of these goats became thinner, an effect caused by the dilation of their internal diameter. These aortic smooth muscle cells maintained contractile formation due to the fact that they contained abundant alpha-smooth muscle actin (SMA) and smooth muscle myosin heavy chain (SMMS). These cells also synthesized redundant matrix metalloproteinase-2 and -9, and the ratio of the SMMS-positive to the SMA-positive area was significantly lower (0.76) than that observed in the control goat (1.00; P < 0.05). The smooth muscle cells demonstrated synthetic-dedifferentiated formation, which is one of the phenotypes of smooth muscle cell function. In conclusion, aortic wall thinness under prolonged continuous flow left heart bypass is caused by over-synthesis of matrix metalloproteinase in smooth muscle cells, and this refers the vascular remodeling process of the extracellular matrix.

Animals↗

Design progress of the ultracompact integrated heart lung assist device--part 2: optimization of the diffuser vane profile.

The configuration of the vaned diffuser of the integrated heart lung assist device (IHLAD) has been revised to reduce mechanical blood trauma caused by the device. The flow visualization study of the flow near the diffuser vanes revealed the existence of a rotating stall which deteriorates the hydrodynamic performance of the device and augments the chance for blood cells to pass through the regions with intense shearing forces. Design changes of the diffuser included decrease in vane number from 7 to 5 and decrease in passage width from 3 mm to 2 mm. This design change was effective to suppress initiation of a rotating stall. Improvement of hydrodynamic performance and antihemolytic properties was confirmed with the newly designed configuration based on the flow visualization study.

Centrifugation↗

Design progress of the ultracompact integrated heart lung assist device--part 1: effect of vaned diffusers on gas-transfer performances.

The integrated heart lung assist device (IHLAD) has been developed to overcome the problems of currently available extracorporeal membrane oxygenation devices. The integrated structure of a centrifugal blood pump and cylindrical bundle of polyolefin hollow-fibers has allowed a remarkably compact size for the device. This study deals with the design change of the IHLAD that added to the vaned diffuser between the impeller of the centrifugal pump and the hollow-fiber bundle with a view to enhancing the gas-transfer performance. Ex vivo gas-transfer performance tests were carried out, as well as hydrodynamic characteristics and hemolysis test using fresh goat blood. The oxygen transfer rate was generally improved, and the carbon dioxide removal rate was slightly improved. Intolerable amount of hemolysis (index of hemolysis= 0.177) was caused by the IHLAD, which must be resolved by improving the design in the future.

Animals↗

High susceptibility of the ACI and spontaneously hypertensive rat (SHR) strains to 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) prostate carcinogenesis.

Carcinogenic responses in the prostate to 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) were compared among seven rat strains (F344, ACI, Spontaneously Hypertensive Rat (SHR), Sprague-Dawley (SD), Wistar, Lewis and Brown Norway (BN)). Ten-week-old animals of each strain were given PhIP at 400 ppm in the diet for 20 weeks then maintained until week 54. The final survival rates were 92, 92, 83, 75, 67, 42 and 42%, respectively, and the SHR strain showed the highest sensitivity with regard to development of prostatic intraepithelial neoplasias (PINs) in the ventral prostate. With regard to the induction of adenocarcinomas of the ventral prostate, the ACI strain was most sensitive, whereas Lewis and F344 rats were relatively resistant. No adenocarcinomas were found in the dorsolateral or anterior prostate or seminal vesicles in any of the strains. The levels of serum testosterone and estrogen, PhIP-DNA adducts and cell kinetics did not correlate with the development of ventral prostatic lesions and thus other factors are presumably responsible for the variations in susceptibility. The present data indicate that ACI and SHR rats are appropriate strains for experimental investigation of PhIP-induced prostate carcinogenesis.

Adenocarcinoma↗

Endoluminal perspective volume rendering of coronary arteries using electron-beam computed tomography.

Remarkable progress has been made in the treatment of coronary heart diseases because of a variety of new interventional devices, but as each new device or procedure has suitability for a particular type of patient or purpose, patient selection is increasingly important. Endoluminal perspective volume renderings of the coronary arteries of a 70-year-old male with old myocardial infarction and recurrent chest pain were carried out using electron-beam computed tomography. Conventional coronary angiography had revealed significant stenosis of the distal portion of the left anterior descending branch, and subsequent conventional balloon angioplasty had failed to expand the stenotic site. Perspective volume rendering images can distinguish differences in objects and evaluate the cross sectional area of the lumen and the morphology of calcification. In the present patient, a huge mass of calcified plaque occupied most of the lumen at a site corresponding to the angiographic site of stenosis. According to this finding, rotational atherectomy was indicated and had a good outcome. The qualitative information for characterizing and determining the morphology of atherosclerotic plaque provided by perspective volume rendering may be useful in selecting the appropriate intervention.

Aged↗

[Cavernous arteriovenous fistula presenting myelopathy: a case report].

Intracranial dural arteriovenous fistula (DAVF) rarely presents with myelopathy. We discuss the diagnosis and treatment of this entity. A 76-year-old woman presented with tetraparesis and sphincter dysfunction. Magnetic resonance imaging demonstrated a high signal intensity from the medulla oblongata to the upper cervical cord on T2-weighted images. Angiograms showed a cavernous DAVF and venous drainage to perimedullary spinal veins via the petrosal vein. It was concluded that, myelopathy had resulted from congestion of the spinal veins. Transarterial embolization of the left cavernous sinus was performed through the left sphenopalatine artery with 25% NBCA after another feeding artery had been occluded using fiber coils. The patient's tetraparesis and sphincter dysfunction gradually improved after embolization, while the high signal intensity on T2-weighted images disappeared within two months after treatment. We should take intracranial DAVF into consideration in patients with myelopathy of unknown origin.

Aged↗

At least thirty-four days of animal continuous perfusion by a newly developed extracorporeal membrane oxygenation system without systemic anticoagulants.

We developed an extracorporeal membrane oxygenation (ECMO) system with high antithrombogenicity and durability characteristics for prolonged continuous cardiopulmonary support. The oxygenator consists of a special hollow-fiber-type polyolefin gas-exchange membrane, which has an ultrathin dense layer in contact with the blood, in order to prevent plasma leakage during protracted use (Platinum Cube NCVC). The centrifugal pump (RotaFlow) is free of seals. The entire blood-contacting surface of the system is coated with a newly developed heparin material (Toyobo-NCVC coating). We performed a venoarterial bypass in a goat, and the ECMO system was driven for 34 days without systemic anticoagulants. Plasma leakage from the oxygenator did not occur, and sufficient gas exchange performance was maintained. Thrombus formation was hardly observed in the ECMO system except in the casing margins of the oxygenator. This ECMO system showed potential for long-term cardiopulmonary support with minimal or no use of systemic anticoagulants.

Animals↗

Prostaglandin synthesis inhibitor affects humoral conditions and oxygen metabolism during normothermic cardiopulmonary bypass.

We have reported that infusion of prostaglandin synthesis inhibitor (PGSI) reduced the severity of hypotension during normothermic cardiopulmonary bypass (CPB). In the present study, we investigated the effects of PGSI on humoral conditions and whole body oxygen metabolism during normothermic CPB conducted for 60 min in 8 adult goats. The PGSI group (n = 4) was administered 100 to 150 mg of flurbiprofen, a potent PGSI, before and during CPB, and the control group (n = 4) was administered noradrenaline (NA) to restore hypotension. The prostaglandin E2 (PGE2) and NA concentrations in the PGSI group were significantly lower than those of the control group (PGE2 8.8 +/- 1.0 versus 30.3 +/- 11.5 pg/ml, NA 431 +/- 197 versus 3847 +/- 2,153 pg/ml). The adrenaline concentration was not significantly different between the groups. The oxygen consumption and the oxygen extraction rate were not significantly different between the groups, but the blood lactate level in the PGSI group was lower than that of the control group (34.3 +/- 7.6 versus 43.7 +/- 3.8 mg/dl). In conclusion, PGSI improves humoral disorder and thus prevents inadequate tissue oxygen delivery.

Analysis of Variance↗

Morphological changes of the arterial systems in the kidney under prolonged continuous flow left heart bypass.

We investigated morphological changes of the arterial systems in the kidneys under prolonged continuous flow left heart bypass. Twelve goats were subjected to 2 weeks of pulsatile left heart bypass followed by 4 weeks of continuous flow left heart bypass (group CF). After autopsy, the kidneys underwent pathological evaluation. Six normal healthy goats were used as controls. The media of the afferent arterioles of group CF were frequently thickened by an increase in the number of the mature smooth muscle cells (SMCs). The juxtaglomerular areas (JGA) were expanded because of an increase in the number and size of SMCs and/or SMC-like cells. Furthermore, the percentage of anti-proliferating cell nuclear antigen antibody-positive cells in the JGA of group CF (9.9 +/- 1.9%) was significantly higher (p = 0.025) than that of the control group (4.6 +/- 3.4%), indicating active proliferation in group CF. We concluded that prolonged continuous flow left heart bypass causes proliferation of SMCs and/or SMC-like cells in the afferent arterioles and their perivascular tissue.

Animals↗

Prostaglandin synthesis inhibitor prevents hypotension without impairing gut perfusion during normothermic cardiopulmonary bypass.

Aortic pressure declines during cardiopulmonary bypass (CPB), particularly at normothermia. It has been reported that administering vasoconstrictors during normothermic CPB (NCPB) to restore perfusion pressure might induce hypoperfusion of splanchnic organs. We have reported that prostaglandin (PG), metabolized in the lung but increased during CPB, might have played a substantial role in hypotension, and that a PG synthesis inhibitor (PGSI) could improve hypotension during CPB. This study was designed to examine whether regional perfusion of splanchnic organs was reduced when PGSI restored systemic perfusion pressure during NCPB. NCPB was performed in eight adult goats for 60 minutes (body weight 57.0 +/- 5.9 kg). PGSI was administered in group P (n = 4), while norepinephrine was administered in group C (n = 4), to keep aortic pressure in the range of 50 to 80 mm Hg. The total systemic flow was maintained at approximately 70 ml/kg/min. Tissue blood flow was measured by means of the colored microsphere method before and 30 and 60 minutes after the start of CPB. In group P, gut blood flows after the start of CPB were higher than those before CPB, significantly in the stomach and jejunum at 30 minutes (p < 0.05), whereas gut blood flows in group C were decreased or not changed. In conclusion, PGSI prevents hypotension without impairing gut perfusion during NCPB.

Animals↗

Ultrastructural alterations in red blood cell membranes exposed to shear stress.

In the mechanism of damage to red blood cells (RBCs) caused by a centrifugal pump, the prolonged effects to the RBC membrane caused by exposure to shear stress remain unclear. We focused on the band 3 protein (B3), one of the major proteins in the membrane skeleton, and investigated the ultrastructural alterations of the RBC membrane with loaded shear stress. Using flow cytometry, the relative amount of B3 was examined in relation to RBC deformability. The results, with continuous exposure to low shear stress, showed cell downsizing, an increase in B3 density, and a decrease in the deformability of the RBC membrane. Exposure to high shear stress does not appear to exert any influence on the membrane skeleton of the RBC. Therefore, in addition to conventional processes including the instantaneous destruction of a cell due to intense shear stresses, the results of the present study indicate the presence of another process based on changes in membrane proteins leading to cell fragmentation. Under low shear stress, the RBC membrane skeleton shows delayed destruction, which is exhibited as a disorder of B3 distribution, and the related membrane dysfunction includes decreases in RBC deformability and stability.

Animals↗

The National Cardiovascular Center electrohydraulic total artificial heart and ventricular assist device systems: current status of development.

Electrohydraulic total artificial heart (EHTAH) and electrohydraulic ventricular assist device (EHVAD) systems have been developed in our institute. The EHTAH system comprises a pumping unit consisting of blood pumps and an actuator, as well as an electronic unit consisting of an internal controller, internal and external batteries, and transcutaneous energy transfer (TET) and optical telemetry (TOT) subunits. The actuator, placed outside the pericardial space, reciprocates and delivers hydraulic silicone oil to the alternate blood pumps through a pair of flexible oil conduits. The pumping unit with an external controller was implanted in 10 calves as small as 55 kg. Two animals survived for more than 12 weeks in a good general condition. The assumed cardiac output ranged between 6 and 10 L/min, the power consumption was 12-18 W, and the energy efficiency was estimated to be 9-11%. Initial implantation of subtotal system including electronic units was further conducted in another calf weighing 73 kg. It survived for 3 days with a completely tether free system. The EHVAD system is developed by using the left blood pump and the actuator of the EHTAH, which were packaged in a compact metal casing with a compliance chamber. In vitro testing demonstrated maximum output more than 9 L/min and more than 13% maximum efficiency. The initial animal testing lasted for 25 days. These results indicate that our EHTAH and EHVAD have the potential to be totally implantable systems.

Animals↗