PubMed Health⌕ Search

Biomedical subjects

Hisashi Kawai

Publications and source records attributed to Hisashi Kawai.

6 recordsLinked to original sources

Constrained tone transformation technique for separation and combination of Mandarin tone and intonation.

This paper addresses a classical but important problem: The coupling of lexical tones and sentence intonation in tonal languages, such as Chinese, focusing particularly on voice fundamental frequency (F1) contours of speech. It is important because it forms the basis of speech synthesis technology and prosody analysis. We provide a solution to the problem with a constrained tone transformation technique based on structural modeling of the F1 contours. This consists of transforming target values in pairs from norms to variants. These targets are intended to sparsely specify the prosodic contributions to the F1 contours, while the alignment of target pairs between norms and variants is based on underlying lexical tone structures. When the norms take the citation forms of lexical tones, the technique makes it possible to separate sentence intonation from observed F0 contours. When the norms take normative F0 contours, it is possible to measure intonation variations from the norms to the variants, both having identical lexical tone structures. This paper explains the underlying scientific and linguistic principles and presents an algorithm that was implemented on computers. The method's capability of separating and combining tone and intonation is evaluated through analysis and re-synthesis of several hundred observed F0 contours.

Algorithms↗

Diffusion-weighted imaging of the liver: technical challenges and prospects for the future.

Diffusion-weighted imaging (DWI) has recently been attempted in the abdominal region. We review diffusion-weighted images of the liver, especially from the technical point of view. We discuss selection of pulse sequence parameters, effects of anti-breathing motion technique, tips for measuring apparent diffusion coefficient (ADC), and utility of superparamagnetic iron oxide (SPIO), showing clinical cases, including those at 3T. Our current trial of new pulse sequencing, such as SPIO-mediated breath-holding black-blood fluid-attenuated inversion recovery (BH-BB-FLAIR), imaging is shown. Some prospects for the future in DWI of the liver are also stated.

Adult↗

Contralateral and ipsilateral responses in primary somatosensory cortex following electrical median nerve stimulation--an fMRI study.

OBJECTIVE: Ten healthy adult subjects were examined using functional magnetic resonance imaging (fMRI) to investigate responses in the contralateral and ipsilateral primary somatosensory cortex (SI) following electrical stimulation of the median nerve. METHODS: The right and left median nerves were stimulated alternately at the wrist in the different sessions. First, the location of the response in contralateral SI was identified following median nerve stimulation, and then, a spherical search volume with a 10mm radius centered on the region of the contralateral response was determined. Whether or not fMRI activation occurred within this sphere following ipsilateral stimulation was examined using a 3T MR imager. RESULTS: A response in contralateral SI was observed in 8 of the 10 subjects in right and left hemisphere. Responses in ipsilateral SI were observed in 6 of 8 subjects in right hemisphere, and the region of the response tended to be posterior to the contralateral region. On the other hand, in left hemisphere, the ipsilateral responses were found in three. CONCLUSIONS: In the present study, not only contralateral SI but also ipsilateral SI was activated following median nerve. The location of the ipsilateral activation was significantly more posterior than the contralateral one in right hemisphere. SIGNIFICANCE: The region of activation in ipsilateral SI was located in the posterior portion of post central gyrus, corresponding to around BA2 and 5 in human.

Adult↗

Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 T.

It has been reported that 3D-FLAIR can reduce the flow artifact resulting from cerebrospinal fluid (CSF) at 1.5 T compared to 2D-FLAIR. Flow-related artifacts tend to be worse at 3 T than at 1.5 T. The purpose of this study was to compare the CSF flow artifacts of 2D-FLAIR and 3D-FLAIR sequences at 3 T in eight healthy volunteers. The grade of CSF-related artifacts were scored through observing the perimedullary cistern, cerebellopontine angle cisterns, fourth ventricule, prepontine cistern, suprasellar cistern, ambient cisterns, sylvian fissures, third ventricle and lateral ventricles. Grading was performed on either axial or sagittal images. The CSF in-flow artifact scores were significantly higher on axial 2D-FLAIR than on axial 3D-FLAIR MPR images in all areas except the bilateral sylvian fissures, and higher on sagittal 2D-FLAIR than on sagittal 3D-FLAIR MPR images in perimedullary, bilateral CP angle and suprasellar cisterns. The CSF-related flow artifacts were significantly reduced by 3D-FLAIR, while structures in the cistern were depicted more clearly, even at 3 T. Further study is necessary to compare the clinical efficacy between 2D-FLAIR and 3D-FLAIR in depicting subtle abnormalities.

Adult↗

High-speed imaging at 3 Tesla: a technical and clinical review with an emphasis on whole-brain 3D imaging.

Improvements to the inherently high specific-absorption rate (SAR) of high-speed imaging at 3T are necessary in order to render this method clinically feasible. Various efforts have been undertaken to improve the associated hardware and software. In this review, we focus on whole-brain isotropic 3D imaging with a turbo spin-echo sequence with variable flip-angle echo trains (3D-TSE-VFL) and present its technical and clinical features. This sequence can be used to acquire images of various contrasts including T2-weighted, fat-suppressed T2-weighted, fluid-attenuated inversion recovery (FLAIR), fat-suppressed FLAIR, and STIR (short tau inversion recovery). Various aspects of 3D-TSE-VFL are discussed, including CSF (cerebrospinal fluid) and metal artifacts, STIR contrast, small-part visualization other than brain, and the possibility of serial subtraction. Some images from clinical cases are presented.

Adult↗

Optimization of diffusion-tensor MR imaging data acquisition parameters for brain fiber tracking using parallel imaging at 3 T.

The purpose of this study was to optimize the parameters of diffusion-tensor magnetic resonance imaging (DT MRI) for brain fiber tracking using a slice thickness of 2 mm, a resolution advantage allowed by the high signal-to-noise ratio at 3 T, combined with an 8-channel phased-array head coil. The b-factor, number of motion probing gradient (MPG) directions, and number of averages were varied, and the results of brain fiber tracking for the pyramidal tract and trigeminal nerve were compared qualitatively and quantitatively. The DT MRI data sufficient for brain fiber tracking in healthy subjects can be obtained in <2 min with a 2-mm slice thickness, 700-s/mm2 b-factor, 6 MPG directions, and no averaging (number of averages=1).

Adult↗