Information loss in visual assessments of medical images.

We applied information theory to quantify information losses in assessing contrast-detail (C-D) analysis. Images of a C-D phantom were acquired with a flat panel detector (FPD) and a computed radiography (CR) by changing surface entrance doses. Six phantom radiographs (FPD: five images; CR: one image) were prepared for visual evaluations. Thirteen radiographers and two radiologists participated in the observation test. Detectability was defined as the shortest length of the cylinders of which border the observers could recognize from the background, and was recorded using row number. Information content was defined as the entropy summation operatorp(i)log(1/p(i)) with detection probabilities p(i), which were calculated from distribution of detection rate of the ith column. Information loss, in unit of bits, was calculated as the difference between information obtained and information content when all the columns were detected. The information losses decreased with the increase in cylinder diameters and with the increase in surface entrance dose. Because the information loss varies depending on distribution of detection rate, this method of using the information theory was expected to be more sensitive in evaluating the C-D image quality than using the averaged values of detectability.

Contrast Sensitivity↗

A method of clustering observers with different visual characteristics.

Evaluation of observer's image perception in medical images is important, and yet has not been performed because it is difficult to quantify visual characteristics. In the present study, we investigated the observer's image perception by clustering a group of 20 observers. Images of a contrast-detail (C-D) phantom, which had cylinders of 10 rows and 10 columns with different diameters and lengths, were acquired with an X-ray screen-film system with fixed exposure conditions. A group of 10 films were prepared for visual evaluations. Sixteen radiological technicians, three radiologists and one medical physicist participated in the observation test. All observers read the phantom radiographs on a transillumination image viewer with room lights off. The detectability was defined as the shortest length of the cylinders of which border the observers could recognize from the background, and was recorded using the number of columns. The detectability was calculated as the average of 10 readings for each observer, and plotted for different phantom diameter. The unweighted pair-group method using arithmetic averages (UPGMA) was adopted for clustering. The observers were clustered into two groups: one group selected objects with a demarcation from the vicinity, and the other group searched for the objects with their eyes constrained. This study showed a usefulness of the cluster method to select personnels with the similar perceptual predisposition when a C-D phantom was used in image quality control.

Cluster Analysis↗

Quantification of synchronous contraction of left ventricle in normal subjects using ECG-gated-SPECT images.

Intact heart muscles are believed to contract synchronously to produce maximum effective work at a minimum energy cost. Temporal correlation coefficients between the left ventricular volume and muscle contraction were introduced to assess the synchronicity of left ventricular contraction (synchronous contraction index, SCI), and applied to eight normal volunteers. Area-contraction and length-shortening parallel to and perpendicular to the long axis were computed from electrocardiogram (ECG)-gated single-photon emission computed tomographies (SPECT) using a homemade computer programme. The cardiac wall was divided into nine segments, and the average values of accumulation of perfusion agents, amplitude of contraction and SCI were obtained in each segment. The area-SCI was 91.4% +/- 4.3% and relatively uniform over the whole cardiac wall (p = 0.014, analysis of variance (ANOVA)), whereas the accumulation and amplitude of contraction varied significantly in different segments (p < 0.0001, ANOVA). This study suggested that in normal subjects the myocardial contraction was synchronous, and that the amplitude of contraction was not spatially uniform.

Adult↗

[Modulation transfer function measurements on magnetic resonance imaging: use of the edge spread function].

A convenient, accurate method to measure the modulation transfer function (MTF) of magnetic resonance(MR) images is discussed. To avoid any distortion of the edge spread function(ESF) which is inadvertently produced by the magnitude operator, the MTF was calculated from the ESF obtained from the salad-oil/water interface. Our MTF findings closely correlated with the MTF findings as calculated by an alternate method (Steckner et al.). Our method was only adapted to some specific sequences and some specific encoding directions, however, MTF was successfully obtained by the magnitude operator without any errors. In our method, the production and arrangement of phantoms were also easier to control. Our new method is therefore considered to be useful for evaluating the resolution property of MR images from various institutions.

Magnetic Resonance Imaging↗