PubMed Health⌕ Search

Biomedical subjects

Hitoshi Shiku

Publications and source records attributed to Hitoshi Shiku.

18 recordsLinked to original sources

Regulation and characterization of the polarity of cells embedded in a reconstructed basement matrix using a three-dimensional micro-culture system.

Three cell lines, that is, the human breast cancer cell line (MCF-7) and the human mammary epithelial cell line (S-1) and its malignant form (T4-2) were embedded in a reconstituted basement membrane (Matrigel) that had 20-nL pyramid-shaped silicon microstructures. The proliferative behavior of the MCF-7 cells was dependent on the surrounding conditions (2-D, collagen gel, or Matrigel), whereas the respiratory activity of a single cell (F(c)) was almost identical under different culture conditions. The F(c) value changed with cellular polarity. The F(c) value for the S-1 cells was observed to decrease slightly, whereas that of the T4-2 cells increased 2 days after cultivation in the microstructures within the Matrigel. However, when the T4-2 cells were cultured in the presence of tyrphostin AG 1478 (T4-2 tyr) to inhibit epidermal growth factor (EGF) signaling, the F(c) value decreased slightly and remained almost constant for an additional 1 week; this was similar to the behavior of the S-1 cells. Further, fluorescence images showed that the T4-2 tyr cells formed polar structures that were similar to those formed by the S-1 cells whereas the T4-2 cells did not form such structures. These results indicate that cellular polarity can be assessed by measuring cellular respiratory activity.

Basement Membrane↗

Electrochemical screening of recombinant protein solubility in Escherichia coli using scanning electrochemical microscopy (SECM).

A microbial array chip with collagen gel spots entrapping living Escherichia coli (E. coli) DH5alpha was applied for the screening of recombinant protein solubilities. The alpha-fragment of beta-galactosidase (betaGal) was fused to the target protein, namely, maltose-binding protein (MBP), to monitor the solubility of MBP. Scanning electrochemical microscopy (SECM) was used to detect the release of p-aminophenol from E. coli cells catalyzed by intracellular betaGal. Comparison of the SECM-based method with the Western blotting-based method indicated that the current response obtained using SECM increased with an increase in the betaGal activity and therefore, with the soluble fraction of MBP in the host cells.

Carrier Proteins↗

Flow sandwich-type immunoassay in microfluidic devices based on negative dielectrophoresis.

Microparticles have been manipulated in a microfluidic channel by means of negative dielectrophoresis (n-DEP), and the approach applied to a heterogeneous immunoassay system. A microfluidic device, with three-dimensional (3-D) microelectrodes fabricated on two substrates, was used to manipulate particle flow in the channel and to capture the particles in the caged area that was enclosed by the collector electrodes. Polystyrene microparticles (6 microm diameters) modified with anti-mouse immunoglobulin G (IgG) were manipulated and captured in the caged area when surrounded by intense n-DEP electric fields. Specifically, particles were trapped when AC voltages with amplitudes of 6-15 V(peak) and frequencies over 500 kHz were applied to the two facing microelectrodes. A heterogeneous sandwich immunoassay was achieved by successively injecting a sample solution containing mouse antigen (IgG), and a solution containing a secondary antibody with a signal source (FITC-labeled anti-mouse IgG antibody), into the channel. The fluorescence intensity from captured particles in the caged area increased with increasing concentrations (10 ng/ml to 10 microg/ml) of mouse IgG. The described system enables mouse IgG to be assayed in 40 min. Thus, the automatic separation of free fractions from desired analytes and labeled antibodies can be achieved using a microfluidic device based on n-DEP.

Biosensing Techniques↗

Topographic, electrochemical, and optical images captured using standing approach mode scanning electrochemical/optical microscopy.

We developed a high-resolution scanning electrochemical microscope (SECM) for the characterization of various biological materials. Electrode probes were fabricated by Ti/Pt sputtering followed by parylene C-vapor deposition polymerization on the pulled optical fiber or glass capillary. The effective electrode radius estimated from the cyclic voltammogram of ferrocyanide was found to be 35 nm. The optical aperture size was less than 170 nm, which was confirmed from the cross section of the near-field scanning optical microscope (NSOM) image of the quantum dot (QD) particles with diameters in the range of 10-15 nm. The feedback mechanism controlling the probe-sample distance was improved by vertically moving the probe by 0.1-3 microm to reduce the damage to the samples. This feedback mode, defined as "standing approach (STA) mode" (Yamada, H.; Fukumoto, H.; Yokoyama, T.; Koike, T. Anal. Chem. 2005, 77, 1785-1790), has allowed the simultaneous electrochemical and topographic imaging of the axons and cell body of a single PC12 cell under physiological conditions for the first time. STA-mode feedback imaging functions better than tip-sample regulation by the conventionally available AFM. For example, polystyrene beads (diameter approximately 6 microm) was imaged using the STA-mode SECM, whereas imaging was not possible using a conventional AFM instrument.

Animals↗

Electrochemical monitoring of cellular signal transduction with a secreted alkaline phosphatase reporter system.

Electrochemical monitoring of cellular signal transduction under three-dimensional (3-D) cell culture conditions has been demonstrated by combining cell-based microarrays with a secreted alkaline phosphatase (SEAP) reporter system. The cells were genetically engineered to produce SEAP under the control of nuclear factor kappaB (NFkappaB) enhancer elements, and they were embedded with a small volume of a collagen gel matrix on a pyramidal-shaped silicon microstructure. Cellular SEAP expression triggered by NFkappaB activation was assessed by two types of electrochemical systems. First, SEAP expression of a 3-D cell array on a chip was continuously monitored in situ for 2 days by scanning electrochemical microscopy (SECM). Since the SECM-based assay enables the evaluation of cellular respiratory activity, simultaneous measurements of cellular viability and signal transduction were possible. Further, we have developed an electrode-integrated cell culture device for parallel evaluation of cellular SEAP expression. The detector electrode was integrated around the silicon microhole. Two kinds of cells were immobilized on the array of microholes on the same chip for comparative characterization of their SEAP activity. This electrochemical microdevice can be applied to evaluate the SEAP expression activity in multiple cellular microarrays by a high-throughput method.

Alkaline Phosphatase↗

A multicellular spheroid array to realize spheroid formation, culture, and viability assay on a chip.

We describe a novel multicellular spheroid culture system that facilitates the easy preparation and culture of a spheroid microarray for the long-term monitoring of cellular activity. A spheroid culture device with an array of pyramid-like microholes was constructed in a silicon chip that was equipped with elastomeric microchannels. A cell suspension was introduced via the microfluidic channel into the microstructure that comprised silicon microholes and elastomeric microwells. A single spheroid can be formed and localized precisely within each microstructure. Since the culture medium could be replaced via the microchannels, a long-term culture (of approximately 2 weeks) is available on the chip. Measurement of albumin production in the hepatoma cell line (HepG2) showed that the liver-specific functions were maintained for 2 weeks. Based on the cellular respiratory activity, the cellular viability of the spheroid array on the chip was evaluated using scanning electrochemical microscopy. Responses to four different chemical stimulations were simultaneously detected on the same chip, thus demonstrating that each channel could be evaluated independently under various stimulation conditions. Our spheroid culture system facilitated the understanding of spheroid formation, culture, and viability assay on a single chip, thus functioning as a useful drug-screening device for cancer and liver cells.

Albumins↗

Oxygen consumption of cell suspension in a poly(dimethylsiloxane) (PDMS) microchannel estimated by scanning electrochemical microscopy.

A quantitative analysis of the oxygen concentration profile near a poly(dimethylsiloxane) (PDMS) microfluidic device was performed using scanning electrochemical microscopy (SECM). A microchannel filled with sodium sulfite (Na(2)SO(3)) aqueous solution was imaged by SECM, showing that the oxygen diffusion layer of the PDMS microchannel was observed to be hemicylindrical. Based on a theoretical analysis of the hemicylindrical diffusion layer of the microchannel, the total oxygen mass transfer rates of oxygen to the PDMS microchannel filled with the Na(2)SO(3) solution was calculated to be (4.01 +/- 0.30) x 10(-12) mol s(-1). This is the maximum value of the oxygen transfer rate for this PDMS microchannel device. The oxygen consumption rate increased almost linearly with the logarithm of the concentration of E. coli cells (10(6) approximately 10(8) cells). The respiratory activity for a single E. coli cell was estimated to be approximately 4.31 x 10(-20) mol s(-1) cell(-1).

Cells↗

Electrochemical microdevice with separable electrode and antibody chips for simultaneous detection of pepsinogens 1 and 2.

An electrochemical microdevice with separable electrode and antibody chips has been developed and applied to detect atrophic gastritis-related proteins, pepsinogen 1 (PG1) and pepsinogen 2 (PG2), based on sandwich-type enzyme-linked immunosorbent assays (ELISAs) with horseradish peroxidase (HRP)-labeled antibody. To fabricate the electrochemical device for simultaneous analysis of several proteins, the electrode chip with eight electrode elements was assembled along with an antibody chip with eight cavities containing immobilized anti-PG1 or anti-PG2. The immunoreactions occurring in the cavities of the device were detected simultaneously by amperometry. The labeled HRP in the cavity in the presence of hydrogen peroxide catalyzed the oxidation of ferrocenemethanol (FMA) to FMA+, which was detected electrochemically by the electrode chip. The amperometric responses of respective cavities in the device increased with increasing concentration of PG1 or PG2 of 0-50 ng/ml, ensuring the simultaneous detection of PG1 and PG2. The detection limits for both PG1 and PG2 were 0.6 ng/ml (S/N=2). The electrode chip was recovered easily by disassembling the electrochemical device; thereby, it was used repeatedly, whereas the antibody chip was discarded. No marked decrease in electrochemical responses was detected after repeated use. Reuse of the electrode chip is beneficial to reduce costs of protein analysis.

Antibodies↗

Amperometric detection of the bacterial metabolic regulation with a microbial array chip.

A microbial array chip with collagen gel spots entrapping living bacterial cells has been applied to investigate the metabolic regulation in Paracoccus denitrificans. Scanning electrochemical microscopy (SECM) was used to monitor the ferrocyanide production that reflects the electron flow in the respiratory chain located within the internal membrane of P. denitrificans. The ferrocyanide production from P. denitrificans largely depends on the types of the carbon source (glucose or lactate), suggesting that the electron flow rate in the respiratory chain depends on the activity of the metabolic pathway located up-stream of the respiratory chain. More importantly, it was found that the enzymes affecting glucose catabolic reactions were significantly up-regulated in cultures with a nutrient agar medium containing D-(+)-glucose as a sole carbon source. Enzyme assays using crude extracts of P. denitrificans were carried out to identify the enzymes expressed at a higher level in cultures supplemented with D-(+)-glucose. It was confirmed that the pyruvate kinase and enzymes of the overall Entner-Doudoroff pathway were highly induced in cultures containing D-(+)-glucose.

Electrochemistry↗

On-chip transformation of bacteria.

On-chip transformation of Escherichia coli cells was accomplished for the first time using a microbial array chip. The continuous E. coli transformation procedures were performed on a chip in which the microcompartment was composed of PDMS microfluidic channels and a silicon substrate predeposited with different plasmid DNAs. The PDMS microfluidic device enabled the parallel transformation of E. coli cells with various plasmid DNAs by separating each transformation area. The phenotypic differences reflecting different plasmid DNAs were identified by various approaches such as colorimetry, fluorometry, and electrochemical methods. This microbial array chip could become a versatile tool for many cell biological applications.

DNA, Bacterial↗

Electrochemical mutagen screening using microbial chip.

Electrochemical microbial chip for mutagen screening were microfabricated and characterized by scanning electrochemical microscopy (SECM). Salmonella typhimurium TA1535 with a plasmid pSK1002 carrying a umuC'-'lacZ fusion gene was used for the whole cell mutagen sensor. The TA1535/pSK1002 cells were exposed to mutagen solutions containing 2-(2-furyl)-3-(5-nitro-2-furyl)acrylamido (AF-2), mitomycin C (MMC) or 2-aminoanthracene (2-AA) and embedded in a microcavity (5nl) on a glass substrate using collagen gel. The beta-galactosidase expression on the microbial chip was electrochemically monitored using p-aminophenyl-beta-d-galactopyranoside (PAPG) as the enzymatic substrate. This system has several advantages compared with the conventional umu test: drastic reduction of the sample volume, less time-consuming for beta-galactosidase detection (free from substrate reaction time) and lower detection limit for the three mutagens (AF-2, MMC, 2-AA). Finally, a multi-sample assay was carried out using the microbial array chip with four microcavities.

Biological Assay↗

Multi-channel 3-D cell culture device integrated on a silicon chip for anticancer drug sensitivity test.

A novel three-dimensional cell culture system was constructed with an array of cell panels (4 x 5) in a silicon chip, together with multi-channel drug containers. Human breast cancer (MCF-7) cells were embedded in a collagen-gel matrix and entrapped in a pyramidal-shaped silicon hole. Each cell panel can be isolated by a channel composed of a microfluid part and a reservoir. A cell panel was exposed to 200 mm KCN for 2 days to demonstrate that each cell panel could be independently evaluated under various stimulation conditions. Based on the cellular respiration activity, the proliferation behavior was continuously monitored on the silicon-based cell array for 5 days using scanning electrochemical microscopy (SECM). The cells entrapped in the device (3-D culture) proliferated normally, and the proliferation rate was lower than that of cells grown in a monolayer cell culture (2-D culture). The effects of three anticancer drugs measured simultaneously on the cell chip were in good agreement with those obtained by a conventional colorimetric assay. Our results suggest that the silicon-based device for 3D culture is appropriate for a chemosensitivity assay involving multi-chemical stimulation.

Antineoplastic Agents↗

A multicellular spheroid-based drug sensitivity test by scanning electrochemical microscopy.

The respiratory activity of a multicellular spheroid was non-invasively monitored by scanning electrochemical microscopy (SECM) to investigate the anticancer drug sensitivity. The effects of the three anticancer drugs, cisplatin (CDDP), 5-fluorouracil (5-FU), and paclitaxel (TXL), were continuously evaluated based on respiratory activity for 5 days. The drug sensitivities obtained by SECM were higher compared to those evaluated by the spheroid volume and conformed to those evaluated by a conventional colorimetric assay. Our results show that the SECM-based assay directly correlates with the number of viable cells within the spheroid, whereas the spheroid volume does not necessarily correlate with the number of viable cells. Furthermore, the results obtained by spheroid culture (3-D) were compared to those of cells cultured in a flask (2-D) and within a collagen gel (3-D). The drug sensitivity of cells cultured in 2-D is more pronounced than that of the cells cultured in 3-D. Since the cellular proliferation status in a 3-D culture is similar to that in vivo, the drug sensitivity test performed in the spheroid culture will give meaningful results that can be extended to an in vivo application. A SECM-based assay is perfectly suitable to directly evaluate the drug sensitivity of the spheroid.

Antimetabolites, Antineoplastic↗

Dielectrophoretic micropatterning with microparticle monolayers covalently linked to glass surfaces.

Two-dimensional micropatterns of microparticles were fabricated on glass substrates with negative dielectrophoretic force, and the patterned microparticles were covalently bound on the substrate via cross-linking agents. The line and grid patterns of microparticles were prepared using the repulsive force of negative dielectrophoresis (n-DEP). The template interdigitated microband array (IDA) electrodes (width and gap 50 mum) were incorporated into the dielectrophoretic patterning cell with a fluidic channel. The microstructures on the glass substrates with amino or sulfhydryl groups were immobilized with the cross-linking agents disuccinimidyl suberate (DSS) and m-maleimidobenzoyl-N-hydroxy-succinimide ester (MBS). Diaphorase (Dp), a flavoenzyme, was selectively attached on the patterned microparticles using the maleimide groups of MBS. The enzyme activity on the patterned particles was electrochemically characterized with a scanning electrochemical microscope (SECM) in the presence of NADH and ferrocenylmethanol as a redox mediator. The SECM images proved that Dp was selectively immobilized onto the surface of microparticles to maintain its catalytic activity.

Journal Article↗

Respiration activity of Escherichia coli entrapped in a cone-shaped microwell and cylindrical micropore monitored by scanning electrochemical microscopy (SECM).

The metabolic activity of E. coli cells embedded in collagen gel microstructures in a cone-shaped well and in a cylindrical micropore was investigated using scanning electrochemical microscopy (SECM), based on the oxygen consumption rate and the conversion rate from ferrocyanide to ferricyanide. The analysis of the concentration profiles for oxygen and ferrocyanide afforded the oxygen consumption rate and the ferrocyanide production rate. A comparison indicated that the ferrocyanide production rates were larger than the oxygen consumption rate, and also that the rates observed in the cylindrical micropore were larger than those observed in the cone-shaped well. The ferrocyanide production rate of a single E. coli cell was calculated to be (5.4 +/- 2.6) x 10(-19) mol s(-1), using a cylindrical micropore system.

Electrochemistry↗

Proliferation assay on a silicon chip applicable for tumors extirpated from mammalians.

We describe a novel anticancer drug sensitivity assay on a silicon chip applicable for tumors extirpated from in vivo mammalians. Human promyelocytic leukemia (HL-60) cells were subcutaneously (s.c.) inoculated in SCID mice, then removed 31 days after the inoculation. The cells were embedded in a small volume (18 nL) of a collagen-gel matrix on a pyramid-shaped silicon microstructure for further cultivation. The respiration activity of the cells on the chip was measured by scanning electrochemical microscopy (SECM). The proliferation behavior was continuously monitored for 6 days. It seemed that the proliferation rate of the cells removed from the mice was lower than that cultured in a flask and conformed to that in mice. The effects of cisplatin (CDDP) and etoposide (VP-16) on the HL-60 cultured in vivo were in good agreement with those obtained by a conventional colorimetric assay. Our results suggest that the SECM-based assay is appropriate for biopsy specimens in a relatively short-time evaluation.

Animals↗

On-chip electrochemical measurement of beta-galactosidase expression using a microbial chip.

[small beta]-Galactosidase expression in a small number of Escherichia coli cells has been measured in real time with an electrochemical sensor chip. E. coli cells were embedded using collagen gel within a micropore which was microfabricated onto a chip. The activity of the expressed [small beta]-galactosidase was determined using p-aminophenyl [small beta]-d-galactopyranoside (PAPG) as a substrate.

Aminophenols↗

Fabrication of microbial chip using collagen gel microstructure.

A microbial chip was fabricated by filling the micropores on a glass substrate with collagen-embedded Escherichia coli(E. coli) cells, and characterized by scanning electrochemical microscopy (SECM) in a solution containing ferricyanide. The activity of the E. coli cells in the collagen gel microstructure was imaged and characterized with SECM by mapping the localized concentration of ferrocyanide produced by the respiration of the cells. The SECM-based activity measurement detected as low as approximately 100 E. coli cells. Furthermore, the optical-microscopic observation indicated that the E. coli cells on the chip proliferated during the incubation. The sequential SECM measurements were performed for the same E. coli chip to obtain the microbial growth curve for a small number of microorganisms.

Collagen↗