PubMed Health⌕ Search

Biomedical subjects

Ho Young Song

Publications and source records attributed to Ho Young Song.

6 recordsLinked to original sources

Synthesis and evaluation of lasonolide A analogues.

Homolasonolide A and 10-desmethyllasonolide A are biologically less active than lasonolide A. The ethyl ester analogue of lasonolide A exhibited higher activity than the parent compound in some biological test.

Cell Division↗

Lasonolide A: structural revision and total synthesis.

The proposed structure of lasonolide A was synthesized employing radical cyclization reactions of beta-alkoxyacrylates for preparation of the tetrahydropyranyl units A and B, but the spectroscopic data did not match those of the natural product. Both enantiomers of a revised structure featuring 17E,25Z double bonds were synthesized, and the (-)-isomer was found to be the biologically active enantiomer.

Antineoplastic Agents↗

The efficacy of metallic stent placement in the treatment of colorectal obstruction.

OBJECTIVE: To evaluate the efficacy of newly designed covered and non-covered coated colorectal stents for colonic decompression. MATERIALS AND METHODS: Twenty-six patients, (15 palliative cases and 11 preoperative) underwent treatment for the relief of colorectal obstruction using metallic stents positioned under fluoroscopic guidance. In 24 of the 26, primary colorectal carcinoma was diagnosed, and in the remaining two, recurrent colorectal carcinoma. Twenty-one patients were randomly selected to receive either a type A or type B stent; for the remaining five, type C was used. Type A, an uncovered nitinol wire stent, was lightly coated to ensure structural integrity. Type B (flare type) and C (shoulder type) stents were polyurethane covered and their diameter was 24 and 26 mm, respectively. The rates of technical success, clinical success, and complications were analyzed using the chi-square test, and to analyse the mean period of patency, the Kaplan-Meier method was used. RESULTS: Thirty of 31 attempted placements in 26 patients were successful, with a technical success rate of 96.8% (30/31) and a clinical success rate of 80.0% (24/30). After clinically successful stent placement, bowel decompression occurred within 1-4 (mean, 1.58+/-0.9) days. Five of six clinical failures involved stent migration and one stent did not expand after successful placement. In the preoperative group, 11 stents, one of which migrated, were placed in ten patients, in all of whom bowel preparation was successful. In the palliative group, 19 stents were placed in 15 patients. The mean period of patency was 96.25+/-105.12 days: 146.25+/-112.93 for type-A, 78.82+/-112.26 for type-B, and 94.25+/-84.21 for type-C. Complications associated with this procedure were migration (n=6, 20%), pain (n=4, 13.3%), minor bleeding (n=5, 16.7%), incomplete expansion (n=1, 3.3%), and tumor ingrowth (n=1, 3.3%). The migration rate was significantly higher in the type-B group than in other groups (p=0.038). CONCLUSION: Newly designed covered and non-covered metallic stents of a larger diameter are effective for the treatment of colorectal obstruction. The migration rate of covered stents with flaring is higher than that of other types. For evaluation of the ideal stent configuration for the relief of colorectal obstruction, a clinical study involving a larger patient group is warranted.

Adolescent↗

Efficacy of a dexamethasone-eluting nitinol stent on the inhibition of pseudo-intimal hyperplasia in a transjugular intrahepatic portosystemic shunt: an experimental study in a swine model.

OBJECTIVE: We wanted to evaluate the feasibility and efficacy of using a dexamethasone (DM)-eluting nitinol stent to inhibit the pseudo-intimal hyperplasia following stent placement in the transjugular intrahepatic portosystemic shunt tract (TIPS) of a swine. MATERIALS AND METHODS: Fifteen stents were constructed using 0.15 mm-thick nitinol wire; they were 60 mm in length and 10 mm in diameter. The metallic stents were then classified into three types; type 1 and 2 was coated with the mixture of 12% and 20%, respectively, of DM solution and polyurethane (PU), while type 3 was a bare stent that was used for control study. In fifteen swine, each type of stent was implanted in the TIPS tract of 5 swine, and each animal was sacrificed 2 weeks after TIPS creation. The proliferation of the pseudo-intima was evaluated both on follow-up portogram and pathologic examination. RESULTS: One TIPS case, using the type 1 stent, and two TIPS cases, using the type 2 stent, maintained their luminal patency while the others were all occluded. On the histopathologic analysis, the mean of the maximum pseudo-intimal hyperplasia was expressed as the percentage of the stent radius that was patent, and these values were 51.2%, 50% and 76% for the type 1, 2, and 3 stents, respectively. CONCLUSION: The DM-eluting stent showed a tendency to reduce the development of pseudo-intimal hyperplasia in the TIPS tract of a swine model with induced-portal hypertension.

Alloys↗