PubMed Health⌕ Search

Biomedical subjects

Hoen-Oh Shin

Publications and source records attributed to Hoen-Oh Shin.

3 recordsLinked to original sources

Preoperative volume calculation of the hepatic venous draining areas with multi-detector row CT in adult living donor liver transplantation: Impact on surgical procedure.

OBJECTIVE: The purpose was to assess the volumes of the different hepatic territories and especially the drainage of the right paramedian sector in adult living donor liver transplantation (ALDLT). METHODS: CT was performed in 40 potential donors of whom 28 underwent partial living donation. Data sets of all potential donors were postprocessed using dedicated software for segmentation, volumetric analysis and visualization of liver territories. During an initial period, volumes and shapes of liver parts were calculated based on the individual portal venous perfusion areas. After partial hepatic congestion occurring in three grafts, drainage territories with special regard to MHV tributaries from the right paramedian sector, and the IRHV were calculated additionally. Results were visualized three-dimensionally and compared to the intraoperative findings. RESULTS: Calculated graft volumes based on hepatic venous drainage and graft weights correlated significantly (r = 0.86, P < 0.001). Mean virtual graft volume was 930 ml and drained as follows: RHV: 680 ml, IRHV: 170 ml (n = 11); segment 5 MHV tributaries: 100 ml (n = 16); segment 8 MHV tributaries: 110 ml (n = 20). When present, the mean aberrant venous drainage fraction of the right liver lobe was 28%. CONCLUSION: The evaluated protocol allowed a reliable calculation of the hepatic venous draining areas and led to a change in the hepatic venous reconstruction strategy at our institution.

Adult↗

3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation.

The aim of this study was to evaluate a software tool for non-invasive preoperative volumetric assessment of potential donors in living donated liver transplantation (LDLT). Biphasic helical CT was performed in 56 potential donors. Data sets were post-processed using a non-commercial software tool for segmentation, volumetric analysis and visualisation of liver segments. Semi-automatic definition of liver margins allowed the segmentation of parenchyma. Hepatic vessels were delineated using a region-growing algorithm with automatically determined thresholds. Volumes and shapes of liver segments were calculated automatically based on individual portal-venous branches. Results were visualised three-dimensionally and statistically compared with conventional volumetry and the intraoperative findings in 27 transplanted cases. Image processing was easy to perform within 23 min. Of the 56 potential donors, 27 were excluded from LDLT because of inappropriate liver parenchyma or vascular architecture. Two recipients were not transplanted due to poor clinical conditions. In the 27 transplanted cases, preoperatively visualised vessels were confirmed, and only one undetected accessory hepatic vein was revealed. Calculated graft volumes were 1110 +/- 180 ml for right lobes, 820 ml for the left lobe and 270 +/- 30 ml for segments II+III. The calculated volumes and intraoperatively measured graft volumes correlated significantly. No significant differences between the presented automatic volumetry and the conventional volumetry were observed. A novel image processing technique was evaluated which allows a semi-automatic volume calculation and 3D visualisation of the different liver segments.

Adult↗

Low-contrast detectability in volume rendering: a phantom study on multidetector-row spiral CT data.

To cope with the increasing amount of CT data, there is growing interest in direct volume-rendering techniques (VRT) as a diagnostic tool. The aim of this phantom study was to analyze the low-contrast detectability (LCD) of VRT compared with multi-planar reformations (MPR). Soft tissue lesions were simulated by spheres of different diameters (3-8 mm). The average lesion density was 15 HU compared with a background density of 35 HU. Two different CT protocols with 40 and 150 mAs were performed on a multi-detector row CT. The scanning parameters were as following: 140 kV; 2x0.5-mm slice collimation; pitch 2 (table movement per rotation/single slice collimation), and reconstruction with 0.5-mm slice thickness at 0.5-mm interval. A B30 kernel was used for reconstruction. The VRT was performed by mapping Hounsfield values to gray levels equal to a CT window (center: 60 HU; window: 370 HU ). A linear ramp was applied for the opacity transfer function varying the maximum opacity between 0.1 and 1.0. A statistical method based on the Rose model was used to calculate the detection threshold depending on lesion size and image noise. Additionally, clinical data of 2 patients with three liver lesions of different sizes and density were evaluated. In VRT, LCD was most dependent on object size. Regarding lesions larger than 5 mm, VRT is significantly superior to MPR (p<0.05) for all opacity settings. In lesions sized 3-5 mm a maximum opacity level approximately 40-50% showed a near equivalent detectability in VRT and MPR. For higher opacity levels VRT was superior to MPR. Only for 3-mm lesions MPR performed slightly better in low-contrast detectability (p<0.05). Compared with MPR, VRT shows similar performance in LCD. Due to noise suppression effects, it is suited for visualization of data with high noise content.

Aged↗