PubMed Health⌕ Search

Biomedical subjects

Hongjing Fu

Publications and source records attributed to Hongjing Fu.

9 recordsLinked to original sources

Monolithic column with zwitterionic stationary phase for capillary electrochromatography.

A capillary electrochromatography (CEC) monolithic column with zwitterionic stationary phases was prepared by in situ polymerization of butyl methacrylate, ethylene dimethacrylate, methacrylic acid, and 2-(dimethyl amino) ethyl methacrylate in the presence of porogens. The stationary phases have zwitterionic functional groups, that is, both tertiary amine and acrylic acid groups, so the ionization of those groups on the zwitterionic stationary phase was affected by the pH values of the mobile phase, and further affects the strength and direction of the electroosmotic flow (EOF). Separations of alkylbenzenes and polycyclic aromatic hydrocarbons based on the hydrophobic mechanism were obtained. Separation of various types of polar compounds, including phenols, anilines, and peptides, on the prepared column were performed under CEC mode with anodic and cathodic EOF, and different separation selectivities of those polar analytes were observed on the monolithic capillary column by using mobile phases with different pH values.

Journal Article↗

Monolithic columns with mixed modes of reversed-phase and anion-exchange stationary phase for capillary electrochromatography.

A capillary electrochromatography (CEC) monolithic column with mixed modes of reversed-phase and anion-exchange stationary phases was prepared by in situ polymerization of 2-(methacryloxy)ethyltrimethylammonium methyl sulfate (MEAMS) and ethylene dimethacrylate (EDMA) in a binary porogenic solvent consisting 1-propanol and 1,4-butanediol. The ammonium groups on the surface of the stationary phase generate an electroosmotic flow (EOF) from cathode to anode, and serve as a strong anion-exchange stationary phase at the same time. The EOF of the stationary phase can be determined by the amount of MEAMS monomer in reaction mixtures during the polymerization. The monolithic stationary phases exhibited reversed-phase chromatographic behavior toward neutral solutes. For charged solutes, hydrophobic as well as electrostatic interaction/repulsion with the monoliths was observed. Separations of aromatic compounds and basic compounds on the prepared column were performed under the mode of CEC. Peak tailing of basic compounds was avoided and the efficient separation of aromatic acids was achieved using neutral mobile phase due to the same direction of EOF and electrophorestic mobility of negatively charged solutes.

Anion Exchange Resins↗

Separation and identification of compounds in Rhizoma chuanxiong by comprehensive two-dimensional liquid chromatography coupled to mass spectrometry.

A comprehensive two-dimensional liquid chromatographic separation system based on the combination of a CN column and an ODS column is developed for the separation of components in a traditional Chinese medicine (TCM) Rhizoma chuanxiong. Two columns are coupled by a two-position, eight-port valve equipped with two storage loops and controlled by a computer. The effluent is detected by both the diode array detector and atmospheric pressure chemical ionization (APCI) mass spectrometer. More than 52 components in the methanol extract of R. chuanxiong were resolved and 11 of them were preliminary identified according to their UV and mass spectra.

Chromatography, Liquid↗

Determination of basic pharmaceuticals in human serum by hydrophilic interaction capillary electrochromatography.

Hydrophilic interaction capillary electrochromatography (HI-CEC) for the determination of basic pharmaceuticals spiked in human serum is described. The organic modifier content, ionic strength, and pH value of the mobile phase as well as the applied voltage are optimized for separation and elution of these drug analytes. Excellent separation was achieved for drugs using a mobile phase composition of 80% v/v acetonitrile in 100 mM triethylamine phosphate (TEAP) buffer at pH 2.8 with column efficiencies for analytes more than 200,000 plates/m. The samples of human serum spiked with basic drugs were directly injected after a simple acetonitrile treatment. The linear range and reproducibility of these basic drugs using an external and internal standard method were compared. As a result, the reproducibility could be greatly improved by using the internal standard method. Good calibration curves with regression coefficients more than 0.998 in the range of 5-160 microg/mL were observed with the internal standard method. The limits of quantitation, based on standards with acceptable relative standard deviations (RSDs), were below 5 microg/mL. The intra- and inter-day precisions, determined as RSDs, were less than 4.57%.

Acetonitriles↗

Polar stationary phases for capillary electrochromatography.

This review article summarizes the variety of polar stationary phases that have been employed for capillary electrochromatographic separations. Compared with reversed-phase stationary phases, the polar alternatives provide a completely different retention selectivity towards polar and charged analytes. Different types of polar stationary phases are reviewed, including the possible retention mechanisms. Electrochromatographic separations of polar solutes, peptides, and basic pharmaceuticals on polar stationary phases are presented.

Chromatography, Liquid↗

Peptide separation in hydrophilic interaction capillary electrochromatography.

Separation of small peptides by hydrophilic interaction capillary electrochromatography (HI-CEC) has been investigated. The negative surface charge of a hydrophilic, strong-cation-exchange stationary phase (PolySULFOETHYL A) provided a substantial cathodic electroosmotic flow (EOF). The influence of acetonitrile content, ionic strength, mobile phase pH as well as applied voltage on the migration of the peptides was studied. Possible retention mechanisms of the peptides in HI-CEC were discussed. It was found that hydrophilic interaction between the solutes and the stationary phase played a major role in this system, especially when mobile phases with high acetonitrile content were used. However, an ion-exchange mechanism and electrophoretic mobility also affect the migration of the peptides in HI-CEC. Elution order and selectivity was proved to be different in HI-CEC and capillary zone electrophoresis (CZE), thus revealing the potential of HI-CEC as a complementary technique to CZE for the separation of peptides. Efficiency and selectivity of HI-CEC for the separation of peptides were demonstrated by baseline separating nine peptides in 6 min.

Chromatography, Micellar Electrokinetic Capillary↗

Optimized preparation of poly(styrene-co- divinylbenzene-co-methacrylic acid) monolithic capillary column for capillary electrochromatography.

Preparation of a poly(styrene-co-divinylbenzene-co-methacrylic acid) monolithic stationary phase for the use in capillary electrochromatography (CEC) has been improved by optimizing the polymerization conditions. It is observed that the reaction time strongly affects column efficiency, while the proportion of isooctane in porogen influences peak symmetry of some solutes seriously. The lifetime of the monolithic columns prepared mainly depends on the pH of buffers used. Reproducibility of electroosmotic flow (EOF) from batch to batch columns are lower than 2.8% relative standard deviation. Unlike other types of capillary electrochromatographic monoliths, a pH-dependent EOF was observed on this type of column. Separation of various types of compounds including aromatic hydrocarbons, hormones, anilines, basic pharmaceuticals, and peptides was achieved. The facile preparation and wide application of this monolithic column may make styrene-based polymer a potential stationary phase in CEC.

Aniline Compounds↗

The separation of biomolecules using capillary electrochromatography.

The unique properties of capillary electrochromatography such as high performance, high selectivity, minimum consumption of both reagents and samples, and good compatibility with mass spectrometry make this technique an attractive one for the analysis of biomolecules including peptides, proteins, carbohydrates, nucleosides and nucleotides. Irreversible adsorption between the biomolecules and the charged packing surface leads to a lack of reproducibility and serious peak tailing, so various approaches have been taken to overcome this and to improve the technique for future challenges.

Biopolymers↗

Separation of peptides on mixed mode of reversed-phase and ion-exchange capillary electrochromatography with a monolithic column.

The mixed mode of reversed phase (RP) and strong cation-exchange (SCX) capillary electrochromatography (CEC) based on a monolithic capillary column has been developed. The capillary monolithic column was prepared by in situ copolymerization of 2-(sulfooxy)ethyl methacrylate (SEMA) and ethylene dimethacrylate (EDMA) in the presence of porogens. The sulfate group provided by the monomer SEMA on the monolithic bed is used for the generation of the electroosmotic flow (EOF) from the anode to the cathode, but at the same time serves as a SCX stationary phase. A mixed-mode (RP/SCX) mechanism for separation of peptides was observed in the monolithic column, comprising hydrophobic and electrostatic interaction as well as electrophoretic migration at a low pH value of mobile phase. A column efficiency of more than 280,000 plates/m for the unretained compound has been obtained on the prepared monoliths. The relative standard deviations observed for t(0) and retention factors of peptides were about 0.32% and less than 0.71% for ten consecutive runs, respectively. Effects of mobile phase compositions on the EOF of the monolithic column and on the separation of peptides were investigated. The selectivity on separation of peptides in the monolithic capillary column could be easily manipulated by varying the mobile phase composition.

Chromatography, High Pressure Liquid↗