PubMed Health⌕ Search

Biomedical subjects

Hongyan Bi

Publications and source records attributed to Hongyan Bi.

4 recordsLinked to original sources

Construction of a biomimetic surface on microfluidic chips for biofouling resistance.

A biomimetic surface has been formed on the poly(methyl methacrylate) (PMMA) microfluidic chips for biofouling resistance on the basis of a simple modification. Accordingly, an amphiphilic phospholipid copolymer of 2-methacryloyloxyethyl phosphorylcholine and n-butyl methacrylate (PMB) was developed to introduce the phosphorylcholine functional groups onto the PMMA surface via the anchoring of hydrophobic n-butyl methacrylate units. The 2-methacryloyloxyethyl phosphorylcholine segments could form hydrophilic domains, considered to be located on the surface, to provide a biocompatible surface. X-ray photoelectron spectroscopy and Fourier transform infrared spectra confirmed the success of surface functionalization. The PMB-modified microchips containing phosphorylcholine moieties exhibited more stable electroosmotic mobility compared with the untreated one. In addition to being characterized for minimized nonspecific adhesion of serum proteins and plasma platelets, the PMB-functionalized microchannels have been exemplified by electrophoresis of proteins. This one-step procedure offers an effective approach for a biomimetic surface design on microfluidic chips, which is promising in high-throughput and complex biological analysis.

Biomimetics↗

Deposition of PEG onto PMMA microchannel surface to minimize nonspecific adsorption.

A protein-resistant surface has been constructed on the poly(methyl methacrylate) (PMMA) microfluidic chips based on a one-step modification. The copolymer of butyl methacrylate (BMA) and poly(ethylene glycol) methyl ether methacrylate (PEGMA) is synthesized to introduce a dense PEG molecular brush-like coating on the PMMA microchannel surfaces via the anchoring effect of the hydrophobic BMA units. The PEGMA segments could produce hydrophilic domains formed on the interface so as to achieve stable electroosmotic flow, and less nonspecific adsorption toward biomolecules. The modification procedure and the properties of the poly(BMA-co-PEGMA)-coated surface have been characterized by FT-IR spectroscopy, confocal fluorescence microscopy, X-ray photoelectron spectroscopy and scanning electron microscopy. The water contact angle and electroosmotic flow of PEG-modified PMMA microchip are measured to be 36 degrees and 5.4 x 10(-4) cm(2) V(-1) s(-1), while those of 73 degrees and 1.9 x 10(-4) cm(2) V(-1) s(-1) for native one, respectively. The PEG-modified microchip has been applied for the electrophoresis separation of proteins, corresponding to the theoretical efficiencies about 16 300 and 412 300 plates m(-1). In the interest of achieving efficient separation while minimizing biofoulings from the serum and plasma, the fabrication of PEG-coated microfluidic chips would provide a biocompatible platform for complex biological analysis.

Adsorption↗

On-chip chiral separation based on bovine serum albumin-conjugated carbon nanotubes as stationary phase in a microchannel.

A novel method of chiral separation based on protein-stationary phase immobilized in a poly(methyl methacrylate) microfluidic chip was developed. BSA conjugated with the shortened carboxylic single-walled carbon nanotubes (SWNTs) was employed as the chiral selector. Successful separation of tryptophan enantiomers was achieved in less than 70 s with a resolution factor of 1.35 utilizing a separation length of 32 mm. This is the first example of chiral separation based on SWNTs-BSA conjugates as stationary phase immobilized in microchip channel. The stability of the stationary phase in the channel was examined by microchip electrophoresis with laser-induced fluorescence detection. Factors that influenced the chiral separation resolution were examined. Under the optimized conditions, the proposed modified chip revealed adequate repeatability concerning run-to-run. These results show that the use of SWNTs-BSA conjugates within microfluidic channels hold great promise for a variety of analytical schemes.

Carbon↗

Strategy for allosteric analysis based on protein-patterned stationary phase in microfluidic chip.

An effective method is presented for the on-chip analysis of chiral interactions with a successful depression of nonspecific adsorption. The alumina gel-derived protein network on poly(methyl methacrylate) (PMMA) microchannel was explored to form a protein-stationary phase and then used to carry out electrophoresis for fast enantioseparation coupled with electrochemical detection. On the basis of the chemical modification of a synthesized copolymer containing silane-functionalized scaffold, alumina sol-gel could react readily with the silane groups and form steady microstructure on the chip surface achieving the encapsulation of functional biomolecules. Compared with the native PMMA microchannels, the modified surfaces exhibited much better wettability, more stable and enhanced electroosmotic mobility, and less nonspecific adsorption. The water contact angle and EOF of alumina-gel-derived PMMA substrate were 22 degrees and 4.3 x 10(-4) cm(2) V(-1) s(-1), compared to those of 73 degrees and 1.9 x 10(-4) cm(2) V(-1) s(-1) from the untreated one, respectively. Bovine serum albumin, acting as a target protein, could be stably and homogeneously immobilized in the modified PMMA microchannel to fabricate a protein-stationary phase. Under a mild condition, D- and L-tryptophan were efficiently separated with a resolution of 1.57. The as-prepared microchip can perform chiral separations within short time, indicating that the general protocol has the potential to provide a platform for high throughput screening of enantiomer candidates such as those biochemical drugs with protein targets and the research of receptor interactions.

Adsorption↗