PubMed Health⌕ Search

Biomedical subjects

Horacio D'Agostino

Publications and source records attributed to Horacio D'Agostino.

8 recordsLinked to original sources

Creating an IHE ATNA-based audit repository.

Compliance with the Health Insurance Portability and Accountability Act (HIPAA) requires gathering audit information from picture archiving and communications systems (PACS) regarding evidence trails of human interactions. Until recently, most PACS users have had limited access to auditing information. Access required resources to handle manual inspection of audit logs, and access to proprietary databases was not always available. Some vendors now produce eXtensible Markup Language (XML) audit logs based on certain events occurring in PACS. However, it is up to the user to convert this information into an easily mined data repository supporting compliance and quality control. This process can be handled in multiple ways, which could mean different audit mechanisms depending on the PACS (or other hospital system) used. It is apparent that an organized method of dealing with audit information is needed. This help may be provided within the Integrating the Healthcare Environment (IHE) framework. The IHE initiative defines a set of profiles, actors, and transactions that create common scenarios for particular workflow processes. The Integration Profiles depict security as a fundamental requirement of the framework. Specifically, the Audit Trail and Node Authentication (ATNA) profile defines standards based mechanisms for securely transmitting and storing audit records in a central repository. The data structure defined by the profile provides a number of record types that capture different audit events. A general feasibility study for storing currently available PACS audit information following the profile is defined, and steps to an automated solution are discussed.

Feasibility Studies↗

Survival in relation to radiotherapeutic modality for brain metastasis: whole brain irradiation vs. gamma knife radiosurgery.

The purpose of this report is to evaluate and compare the survival of patients with brain metastasis (BRM) treated by whole brain irradiation (WBI) using linear energy accelerator (LINAC) and by stereotactic radiosurgery using gamma knife. This study consists of a series of 67 patients with BRM treated with WBI between 1998 and 1999 and 53 patients with BRM treated with gamma knife radiosurgery (GKRS) between 2000 and 2001. A retrospective study of the data was performed and the overall survival between these 2 groups was analyzed. The comparability of these 2 groups was tested by chi2 and t test values. Log-rank test was used in the survival comparison. The 1-year survival rate was 26.3% and 22.6%, and corresponding mean survival was 7.8 months and 6.7 months for WBI and GKRS groups, respectively. There was no statistically significant difference between these 2 groups' survival. It was evident from imaging defined lesions that with GKRS the lesions were reduced, stabilized, or disappeared in 89% of cases. Survival of patients with BRM treated with WBI or GKRS was similar in these series. The present study suggests that good tumor response by GKRS does not translate in longer patient survival.

Adult↗

Retrievability of uncoated versus paclitaxel-coated Günther-Tulip IVC filters in an animal model.

PURPOSE: To compare in a pilot study, the retrievability and inferior vena cava (IVC) wall reaction elicited by uncoated and paclitaxel-coated Günther-Tulip filters in the animal model. MATERIALS AND METHODS: Three groups with five pigs each underwent infrarenal IVC implantation of Günther-Tulip filters. Paclitaxel-coated filters were used in Groups A and B and uncoated filters were used in Group C. Filters were removed at 14, 19, 22, 26, and 30 days after implantation. A laparotomy was performed to remove filters from animals in group A and filters from animals in groups B and C that could not be retrieved via the right transjugular approach. Filter-induced venous wall changes were evaluated by examination of IVC venography, feasibility of filter removal at different implantation times, and laparotomy and microscopic findings. Feasibility of filter retrieval and venous wall changes were correlated. RESULTS: IVC cavography showed no abnormality. Filters in animals in group B were uneventfully removed by a right jugular approach. Uncoated filter removal was not feasible in three of five animals in group C (19, 22, and 26 days). Microscopically, animals in group A had absent filter-induced IVC wall changes at 14, 19, 22, and 26 days and minimal changes at 30 days post implantation; animals in group B had absent filter-induced IVC wall changes at 14, 19, and 22 days and minimal changes at 26 and 30 days; animals in group C had moderate filter-induced IVC wall changes at 14 days and severe changes at 19, 22, 26, and 30 days. CONCLUSIONS: This pilot study suggests that endothelial reaction to the presence of IVC filters in the porcine model is diminished by addition of paclitaxel coating to these filters. Further studies are necessary to substantiate these results.

Animals↗

Transradial approach to coil embolization of an intracranial aneurysm.

PURPOSE: To report the use of a transradial approach to coil embolization of an intracranial aneurysm in a morbidly obese patient. TECHNICAL NOTE: When the transfemoral approach was inaccessible in a morbidly obese patient with a ruptured intracranial aneurysm, coil embolization was performed via a 6-F sheath placed in the radial artery. Multiple platinum coils were delivered to exclude the 14-mm basilar tip aneurysm. Because heparin was not reversed, the sheath was left in the artery for 24 hours then removed. The radial artery was pulsatile, and blood supply to the hand was good. CONCLUSIONS: The radial artery appears to be a suitable route for access to the intracranial vessels when the femoral artery is not available.

Adult↗

Ileocolic arteriovenous fistula with superior mesenteric vein aneurysm: endovascular treatment.

We report a case of a venous aneurysm secondary to an acquired ileocolic arteriovenous fistula in a 64-year-old woman with recurrent abdominal pain and history of appendectomy. The aneurysm was diagnosed by ultrasound and computed tomography. Angiography showed an arteriovenous fistula between ileocolic branches of the superior mesenteric artery and vein. This vascular abnormality was successfully treated with coil embolization.

Aneurysm↗

Stent-graft treatment of pseudoaneurysms and arteriovenous fistulae in the carotid artery.

The purpose of this study was to assess the safety and efficacy of stent-graft placement in the management of arteriovenous fistulae (AVF) and pseudoaneurysms (PAs) involving the carotid artery (CA). Twenty-two patients (16 men, 6 women) with a CA AVF (n = 5) or PA (n = 17) owing to a gunshot or stab wound, carotid endarterectomy, blunt trauma, a tumor, spontaneous dissection, or a central venous catheter were treated with percutaneous placement of stent grafts. The patients presented with tumor, bruit, headache, mouth and tracheostomy bleeding, transitory hemiparesis, seizure, or stroke. Diagnoses were made by using computed tomographic angiography (CTA) and digital subtraction angiography. Fourteen lesions were in the common CA; eight were in the internal CA. Homemade devices and stent grafts from a variety of manufacturers were employed. Follow-up evaluations included clinical, CTA, and Doppler ultrasound assessments. All patients had resolution of the PA or AVF. In one patient with a large petrous PA, acute occlusion of the CA developed after placement of three balloon-expandable stent grafts, but there were no neurologic complications because the circle of Willis was functional. During follow-up ranging from 2 months to 13 years, asymptomatic 90% stenosis owing to stent compression was observed on Doppler ultrasound and angiographic examinations in a patient with an autologous vein-covered stent graft in the internal CA. Three other patients died of causes unrelated to stent-graft placement. In all other patients, the stent graft remained patent. Our results indicate that stent grafting is an acceptable alternative to surgery in the treatment of AVF and PAs in the CA.

Adult↗

Role of imaging in the diagnosis of the superior mesenteric artery syndrome.

The purpose of this report is to describe the role of imaging in the diagnosis of the superior mesenteric artery syndrome. A review of clinical symptoms, diagnostic imaging, and patient management of superior mesenteric artery syndrome constitutes the core of this report. Images of upper gastrointestinal series, multislice CT, and CT angiography with multiplanar reconstruction illustrate their usefulness in the diagnosis of 3 patients with superior mesenteric artery syndrome.

Adult↗