PubMed Health⌕ Search

Biomedical subjects

Hossain M Deloar

Publications and source records attributed to Hossain M Deloar.

6 recordsLinked to original sources

System design and development of a pinhole SPECT system for quantitative functional imaging of small animals.

Recently, small animal imaging by pinhole SPECT has been widely investigated by several researchers. We developed a pinhole SPECT system specially designed for small animal imaging. The system consists of a rotation unit for a small animal and a SPECT camera attached with a pinhole collimator. In order to acquire complete data of the projections, the system has two orbits with angles of 90 degrees and 45 degrees with respect to the object. In this system, the position of the SPECT camera is kept fixed, and the animal is rotated in order to avoid misalignment of the center of rotation (COR). We implemented a three dimensional OSEM algorithm for the reconstruction of data acquired by the system from both the orbitals. A point source experiment revealed no significant COR misalignment using the proposed system. Experiments with a line phantom clearly indicated that our system succeeded in minimizing the misalignment of the COR. We performed a study with a rat and 99mTc-HMDP, an agent for bone scan, and demonstrated a dramatic improvement in the spatial resolution and uniformity achieved by our system in comparison with the conventional Feldkamp algorithm with one set of orbital data.

Animals↗

Rotational and translational reproducibility of newly developed Leksell frame-based relocatable fixation system.

PURPOSE: The aim of this study was to evaluate three-dimensional movement of the cranium in a relocatable frame using positions of anatomical landmarks obtained from repeated quality-assurance (QA) computed tomography (CT) studies. MATERIALS AND METHODS: We analyzed 17 series of QA-CT data representing five patients who underwent stereotactic radiotherapy for treatment of acoustic neurinoma. Helical-CT scans with 1-mm collimation were obtained at the time of treatment planning and during the course of treatment. The right and left short processes of the incus and the top of the crista galli were used as the three anatomical reference points. RESULTS: Fluctuations in distance among the reference points were all <1 mm. The translational displacements for these points were <2 mm, with standard deviations (SD) of <2 mm. A plane that included all three reference points was defined as the reference plane. To investigate the direction of cranial rotation for each QA-CT scan, unit normal vectors of the reference plane were obtained. Three-dimensional analyses indicated that cranial rotation was greatest along the X-axis, followed by the Y-axis, with the least rotation along the Z-axis. CONCLUSION: The result suggested that movement of the craniocaudal axis in the sagittal plane was a major factor behind displacement of the cranium.

Adult↗

Differences in pulmonary function before vs. 1 year after hypofractionated stereotactic radiotherapy for small peripheral lung tumors.

PURPOSE: To evaluate long-term pulmonary toxicity of stereotactic radiotherapy (SRT) by pulmonary function tests (PFTs) performed before and after SRT for small peripheral lung tumors. METHODS AND MATERIALS: A total of 17 lesions in 15 patients with small peripheral lung tumors, who underwent SRT between February 2000 and April 2003, were included in this study. Twelve patients had primary lung cancer, and 3 patients had metastatic lung cancer. Primary lung cancer was T1-2N0M0 in all cases. Smoking history was assessed by the Brinkman index (number of cigarettes smoked per day multiplied by number of years of smoking). Prescribed radiation doses at the 80% isodose line were 40-60 Gy in 5-8 fractions. PFTs were performed immediately before SRT and 1 year after SRT. Test parameters included total lung capacity (TLC), vital capacity (VC), forced expiratory volume in 1 s (FEV1.0), and diffusing capacity of lung for carbon monoxide (DLCO). PFT changes were evaluated in relation to patient- and treatment-related factors, including age, the Brinkman index, internal target volume, the percentages of lung volume irradiated with >15, 20, 25, and 30 Gy (V15, V20, V25, and V30, respectively), and mean lung dose. RESULTS: There were no significant changes in TLC, VC, or FEV1.0 before vs. after SRT. The mean percent change from baseline in DLCO was significantly increased by 128.2%. Univariate and multivariate analyses revealed a correlation between DLCO and the Brinkman index. CONCLUSIONS: One year after SRT as compared with before SRT, there were no declines in TLC, VC, and FEV1.0. DLCO improved in patients who had been heavy smokers before SRT, suggesting a correlation between DLCO and smoking cessation. SRT seems to be tolerable in view of long-term lung function.

Aged↗

Measurement of beam-axis displacement from the isocenter during three-dimensional conformal radiosurgery with a micro-multileaf collimator.

We describe the displacement of the beam-axis from the planning isocenter in clinical situations during three-dimensional conformal radiosurgery using an Acculeaf bi-directional micro-multileaf collimator. The displacements were recorded for 64 ports using a video imaging system and a stereotactic arc. The mean displacement was 0.41+/-0.25 mm.

Brain Neoplasms↗

Evaluation of penetration and scattering components in conventional pinhole SPECT: phantom studies using Monte Carlo simulation.

In quantitative pinhole SPECT, photon penetration through the collimator edges (penetration), and photon scattering by the object (object scatter) and collimator (collimator scatter) have not been investigated rigorously. Monte Carlo simulation was used to evaluate these three physical processes for different tungsten knife-edge pinhole collimators using uniform, hotspot and donut phantoms filled with 201Tl, 99mTc, 123I and 131I solutions. For the hotspot phantom, the penetration levels with respect to total counts for a 1 mm pinhole aperture were 78%, 28% and 23% for 131I, 123I and 99mTc, respectively. For a 2 mm aperture, these values were 65% for 131I, 16% for 123I and 12% for 99mTc. For all pinholes, 201Tl penetration was less than 4%. The evaluated scatter (from object and collimator) with a hotspot phantom for the 1 mm pinhole was 24%, 16%, 18% and 13% for 201Tl, 99mTc, 123I and 131I, respectively. Summation of the object and collimator scatter for the uniform phantom was approximately 20% higher than that for the hotspot phantom. Significant counts due to penetration and object and collimator scatter in the reconstructed image were observed inside the core of the donut phantom. The collimator scatter can be neglected for all isotopes used in this study except for 131I. Object scatter correction for all radionuclides used in this study is necessary and correction for the penetration contribution is necessary for all radionuclides but 201Tl.

Absorption↗

Dependency of energy and spatial distributions of photons on edge of object in brain SPECT.

OBJECTIVES: Accurate mu maps are important for quantitative image reconstruction in SPECT. The Compton scatter energy window (CSW) technique has been proposed to define the outline of objects. In this technique, a lower energy window image is acquired in addition to the main photo-peak energy window. The image of the lower energy window is used to estimate the edge of the scanned object to produce a constant attenuation map. The aim of this study was to investigate the dependency of CSW on the spatial and energy distribution of radioisotope to predict the edges of objects. METHODS: Two particular cases of brain study were considered, namely uniform distribution and non-uniform distribution using Monte Carlo simulation and experiments with uniform cylindrical phantom and hotspot phantom. The phantoms were filled with water and a radioactive solution of 99mTc. For each phantom, 20%, 30%, 40% and 50% thresholds of the mean profile were applied to estimate Ewt, the energy window for minimum difference between the estimated and true edge of objects. RESULTS: The Ewt's were 100-120 keV with a 40% threshold and 92-114 keV with a 30% threshold for uniform and hotspot phantoms, respectively. CONCLUSIONS: Edge of the objects with CSW technique varies with energy window and thresholds. Careful setting of the energy window is required to use the CSW technique.

Algorithms↗