PubMed Health⌕ Search

Biomedical subjects

Hossein Ahmadzadeh

Publications and source records attributed to Hossein Ahmadzadeh.

10 recordsLinked to original sources

Analysis of mitochondria isolated from single cells.

Bulk studies are not suitable to describe and study cell-to-cell variation, which is of high importance in biological processes such as embryogenesis, tissue differentiation, and disease. Previously, capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) was used to measure the properties of organelles isolated from millions of cells. As such, these bulk measurements reported average properties for the organelles of cell populations. Similar measurements for organelles released from single cells would be highly relevant to describe the subcellular variations among cells. Toward this goal, here we introduce an approach to analyze the mitochondria released from single mammalian cells. Osteosarcoma 143B cells are labeled with either the fluorescent mitochondrion-specific 10-N-nonyl acridine orange (NAO) or via expression of the fluorescent protein DsRed2. Subsequently, a single cell is introduced into the CE-LIF capillary where the organelles are released by a combined treatment of digitonin and trypsin. After this treatment, an electric field is applied and the released organelles electromigrate toward the LIF detector. From an electropherogram, the number of detected events per cell, their individual electrophoretic mobilities, and their individual fluorescence intensities are calculated. The results obtained from DsRed2 labeling, which is retained in intact mitochondria, and NAO labeling, which labels all mitochondria, are the basis for discussion of the strengths and limitations of this single-cell approach.

Acridine Orange↗

On the possibility of applying noncovalent dyes for protein labeling in isoelectric focusing.

Noncovalent fluorescent dyes are widely used for protein quantification and postcolumn detection in electrophoretic separations and recently some attempts to separate the precolumn labeled proteins using isoelectric focusing (IEF) have been made. In the present study, the possibility of applying the technique of protein labeling with noncovalent dyes for IEF is investigated. We found that fluorescent signal emitted by NanoOrange dye increases essentially in presence of carrier ampholyte (CA) components, which makes problematic a reliable protein detection in CA environment. Since in an isoelectric focusing mode the CA species are present in much greater concentration than the concentrations of fractionated proteins, the method of protein labeling with NanoOrange is not suitable for precolumn labeling and cannot be used for CA-IEF, at least without more detailed study of the dye-protein interaction mechanism.

Ampholyte Mixtures↗

On-column labeling for capillary electrophoretic analysis of individual mitochondria directly sampled from tissue cross sections.

This technical note reports on a new procedure to on-column-label organelles sampled from a tissue cross section into a fused silica capillary. These organelles are then analyzed by capillary electrophoresis with postcolumn laser-induced fluorescence detection. In this procedure, the fluorescent label does not come in contact with the tissue, which facilitates visualization of the sampled tissue cross section. In addition, on-column labeling allows for better control of the reaction time and fluorescent label concentrations. As a proof-of-principle, we show results of mitochondria from rat gastrocnemius muscle cross sections that were on-column-labeled with 10-N-nonyl acridine orange (NAO), a mitochondrion-specific probe, and compare them with results for NAO in-tissue labeling of the same tissue. The new organelle labeling procedure reported here may easily be extended to the analysis of individual organelles in other biological samples and may become a valuable tool in studies investigating the role of mitochondria in muscle aging and exercise physiology.

Anatomy, Cross-Sectional↗

Within the cell: analytical techniques for subcellular analysis.

This review covers recent developments in the preparation, manipulation, and analyses of subcellular environments. In particular, it highlights approaches for (1) separation and detection of individual organelles, (2) preparation of ultra-pure organelle fractions, and (3) utilization of novel labeling strategies. These approaches, based on innovative technologies such as microfluidics, immunoisolation, mass spectrometry and electrophoresis, suggest that subcellular analyses will soon become as commonplace as single cell and bulk cellular assays.

Electrophoresis↗

Automated analysis of individual particles using a commercial capillary electrophoresis system.

Capillary electrophoretic analysis of individual submicrometer size particles has been previously done using custom-built instruments. Despite that these instruments provide an excellent signal-to-noise ratio for individual particle detection, they are not capable of performing automated analyses of particles. Here we report the use of a commercial Beckman P/ACE MDQ capillary electrophoresis (CE) instrument with on-column laser-induced fluorescence (LIF) detection for the automated analysis of individual particles. The CE instrument was modified with an external I/O board that allowed for faster data acquisition rates (e.g. 100 Hz) than those available with the standard instrument settings (e.g. 4 Hz). A series of eight hydrodynamic injections expected to contain 32 +/- 6 particles, each followed by an electrophoretic separation at -300 V cm(-1) with data acquired at 100 Hz, showed 28 +/- 5 peaks corresponding to 31.9 particles as predicted by the statistical overlap theory. In contrast, a similar series of hydrodynamic injections followed by data acquisition at 4 Hz revealed only 8 +/- 3 peaks suggesting that the modified system is needed for individual particle analysis. Comparison of electropherograms obtained at both data acquisition rates also indicate: (i) similar migration time ranges; (ii) lower variation in the fluorescence intensity of individual peaks for 100 Hz; and (iii) a better signal-to-noise ratio for 4 Hz raw data. S/N improved for 100 Hz when data were smoothed with a binomial filter but did not reach the S/N values previously reported for post-column LIF detection. The proof-of-principle of automated analysis of individual particles using a commercially available CE system described here opens exciting possibilities for those interested in the study and analyses of organelles, liposomes, and nanoparticles.

Automation↗

Asymmetry between sister cells in a cancer cell line revealed by chemical cytometry.

We introduce instrumentation and methodology for two-channel chemical cytometry of sister cells-two cells born from division of the same mother cell. The method is based on capillary electrophoresis with laser-induced fluorescence detection and allows simultaneously probing multiple intracellular components in sister cells. To test the new technology, we compared the expression patterns of green fluorescent protein (GFP) between the sisters in cultured cancer cells stably transfected with a GFP-expressing construct. We found that all sister cells had detectable asymmetry in the GFP expression patterns with a confidence level of higher than 95%. To our best knowledge, this is the first reported observation of asymmetric patterns of protein expression in sister cells in a cancer cell line. The proposed technology can reliably detect minor differences in chemical contents between sister cells, which makes it a potentially indispensable tool in studying the molecular mechanisms of developmental processes. It will be especially valuable in quantitative studies of cells with complex proliferation kinetics (e.g., stem cells).

Animals↗

Direct sampling from muscle cross sections for electrophoretic analysis of individual mitochondria.

Muscle is a highly heterogeneous tissue. Practical approaches to sample selectively small regions of muscle cross sections would help to effectively utilize analytical techniques on muscle studies while taking into account tissue heterogeneity. In this report, semimembranosus muscle tissue cross sections were directly sampled and analyzed by capillary electrophoresis (CE) with laser-induced fluorescence detection (LIF). Prior to CE-LIF analysis, a small region in the muscle cross section was stained with 10-nonyl acridine orange (NAO) which is a mitochondrion-selective fluorescent probe known to form a stable complex with cardiolipin, a phospholipid found only in mitochondria. By micromanipulation, the injection end of the capillary was brought into contact with the tissue exhibiting fluorescently labeled mitochondria. Sampling from a region similar in size to the cross section of a single fiber was carried out by applying 11 kPa of negative pressure for 3 s. When an electric field of -200V/cm was applied, fluorescently labeled mitochondria electromigrated and were individually detected by postcolumn LIF detection. For each sample, the electropherogram displays a migration time window with a collection of narrow peaks. The collection of individual peak measurements is represented as a distribution of individual intensities related to cardiolipin content of mitochondria and a distribution of individual electrophoretic mobilities. Positioning the capillary injection end was sufficiently spatially accurate to deplete mitochondria in the sampled region upon repetitive injections. Treatment of a muscle cross section with a protease (trypsin) prior to mitochondria sampling resulted in a higher number of detected mitochondria, suggesting that one of the effects of this enzyme is a partial digestion of the muscles myofibrils, which eases the release of interfibrillar mitochondria entangled within these fibers. The protease treatment also resulted in changes to the electrophoretic mobility distribution of individual mitochondria, which may imply that partial digestion of proteins bound to the mitochondria contributes to the alteration in the electrophoretic mobility of mitochondria. The ability to sample a region as small as a single muscle fiber cross section and its direct CE-LIF analysis opens exciting possibilities for the direct analysis of muscle biopsies and mapping the mitochondrial electrophoretic properties in highly heterogeneous tissues.

Aminoacridines↗

Capillary coating for protein separation based on Si-O and Si-C covalent bond formation for capillary electrophoresis with laser-induced fluorescence detection.

Protein adsorption to capillary walls is one of the major complications in protein analyses with capillary electrophoresis (CE). Coating the capillary with different materials is used to reduce the adsorption. This chapter overviews different approaches used for capillary coating and concentrates on those utilizing Si-O and Si-C covalent bonds. The apparatus and methods are presented for capillary coating using Si-O and Si-C chemistry. Furthermore, procedures are described for monitoring the quality of coating.

Acrylic Resins↗

On-column labeling reaction for analysis of protein contents of a single cell using capillary electrophoresis with laser-induced fluorescence detection.

This chapter presents methods for capillary electrophoresis (CE) fingerprinting of proteins in a cell extract and in single cells. A custom-made CE instrument with laser-induced fluorescence (LIF) detection, used for the analyses, is described. Detailed procedures are given for: (1) on column labeling of proteins with a fluorogenic reagent, 5-furoyl quinoline-3-carboxaldehyde, (2) CE separation of labeled proteins, (3) preparation of a protein extract from cultured cells, and (4) manipulations associated with analyses of proteins in single cells. More than 20 relevant publications are cited in this chapter to assist the reader with adopting the presented methods.

Animals↗

Heterogeneity of protein labeling with a fluorogenic reagent, 3-(2-furoyl)quinoline-2-carboxaldehyde.

Fluorogenic reagents are used for protein labeling when high-sensitivity fluorescence detection is required. Similar to traditional labeling with activated fluorescent dyes, such as fluorescein isothiocyanate, a fluorogenic reaction is expected to change the physical-chemical properties of proteins. Knowledge of these changes may be essential for efficient separation and identification of labeled proteins. Here we studied the effect of labeling of myoglobin with a fluorogenic reagent on the acid-base properties of the protein. The fluorogenic reagent used was 3-(2-furoyl)quinoline-2-carboxaldehyde (FQ). In slab-gel isoelectric focusing, we found that the labeling reaction generated at least six species with pI values lower than that of non-labeled myoglobin. These species can be identified as products of progressive labeling of myoglobin with one to six FQ molecules. The same series of FQ-labeled species were observed when the reaction products were analyzed by capillary zone electrophoresis. The comparison of experimental and theoretical pI values allowed us to elucidate the labeling pattern--the number of FQ molecules corresponding to each labeled product detected by isoelectric focusing.

Electrophoresis, Capillary↗