PubMed Health⌕ Search

Biomedical subjects

Howard A Rowley

Publications and source records attributed to Howard A Rowley.

13 recordsLinked to original sources

Selection of acute ischemic stroke patients for intra-arterial thrombolysis with pro-urokinase by using ASPECTS.

BACKGROUND: Previous studies have suggested that baseline computed tomographic (CT) scans might be a useful tool for selecting particular ischemic stroke patients who would benefit from thrombolysis. The aim of the present study was to assess whether the baseline CT scan, assessed with the Alberta Stroke Program Early CT Score (ASPECTS), could identify ischemic stroke patients who might particularly benefit from intra-arterial thrombolysis of middle cerebral artery occlusion. METHODS: Baseline and 24-hour follow-up CT scans of patients randomized within 6 hours of symptoms to intra-arterial thrombolysis with recombinant pro-urokinase or control in the PROACT-II study were retrospectively scored by using ASPECTS. Patients were stratified into those with ASPECTS >7 or < or =7. Independent functional outcome at 90 days was compared between the 2 strata according to treatment assignment. RESULTS: The analysis included 154 patients with angiographically confirmed middle cerebral artery occlusion. The unadjusted risk ratio of an independent functional outcome, in favor of treatment, in the ASPECTS >7 group was 5.0 (95% confidence interval [CI], 1.3 to 19.2) compared with 1.0 (95% CI, 0.6 to 1.9) in the ASPECTS < or =7 group. After adjustment for baseline characteristics, the risk ratio in the ASPECTS score >7 was 3.2 (95% CI, 1.2 to 9.1). Similar favorable treatment effects were observed when secondary outcomes were used, but these did not reach statistical significance. CONCLUSIONS: Ischemic stroke patients with a baseline ASPECTS >7 were 3 times more likely to have an independent functional outcome with thrombolytic treatment compared with control. Patients with a baseline ASPECTS < or =7 were less likely to benefit from treatment. This observation suggests that ASPECTS can be both a useful clinical tool and an important method of baseline risk stratification in future clinical trials of acute stroke therapy.

Acute Disease↗

High-resolution 3D T2-weighted fast spin echo: new applications in the orbit.

Recent developments have made available for ophthalmologic MR imaging a very high-resolution 3D fast spin echo T2 (3D FSE T2) sequence, which runs in a standard head coil. A modification of this technique, 3D FSEz T2, uses a zero-filled slice interpolation method during post-processing to further improve spatial resolution. We describe the technique and share our early clinical observations in patients with ocular masses. Briefly, the additional information from the 3D FSEz T2 resulted in a change in diagnosis from the conventional imaging series in 11 of (41%) 27 studies, usually through the identification of previously treated retinoblastoma lesions. The new sequence significantly increased diagnostic confidence in six (38%) of the remaining 16 cases, usually through better anatomical detail and lesion conspicuity, and did not change interpretation in 10 cases. Such an approach improves diagnostic confidence and may eliminate the need for a dedicated surface coil examination.

Fourier Analysis↗

Factors influencing outcome and treatment effect in PROACT II.

BACKGROUND AND PURPOSE: The PROACT II study demonstrated a significant benefit from treatment with intra-arterial pro-urokinase (r-proUK) in patients with middle cerebral artery occlusion treated within 6 hours of stroke onset. The purpose of the current study was to examine baseline factors to determine predictors of good outcome and response to treatment. METHODS: We selected from the baseline clinical, radiologic, and angiographic data variables that considered possibly related to outcome. A univariate analysis was performed to examine the association between these baseline factors and good outcome, defined as a modified Rankin scale score <or=2. A multivariate model then selected the most important variables independently influencing prognosis. A risk score for each patient was constructed on the basis of the patient's individual values for each independent variable. Patients were stratified into risk quartiles based on their risk scores, and an odds ratio for each risk quartile was calculated. The treatment effects of each quartile were compared. RESULTS: In the univariate analysis, screening National Institutes of Health stroke scale (NIHSS) score and age were strongly associated with good outcome. The multivariate model selected age, NIHSS score, and CT hypodensity as the most important prognostic variables. Dividing patients into quartiles based on risk scores achieved a uniform gradient of probability of good outcomes. A trend toward benefit of r-proUK treatment was seen in all risk quartiles, and no differential treatment effect was observed across risk groups. CONCLUSIONS: There was no evidence of differential effect of r-proUK across subgroups of patients stratified by risk.

Adult↗

Automatic calculation of the arterial input function for cerebral perfusion imaging with MR imaging.

An automated method for determination of arterial input function (AIF) for rapid determination of cerebral perfusion with dynamic susceptibility contrast magnetic resonance (MR) imaging was derived. In 100 patients, the automated method was used to create images of relative blood flow, relative cerebral blood volume, and mean transit time. In 20 patients, the voxel chosen with the automated AIF correlated with a large cerebral artery and exhibited less partial-volume averaging when compared with an AIF chosen manually. It is possible to reliably determine the AIF at dynamic susceptibility contrast MR imaging and eliminate the need for operator input and lengthy postprocessing.

Adolescent↗

White matter tractography using diffusion tensor deflection.

Diffusion tensor MRI provides unique directional diffusion information that can be used to estimate the patterns of white matter connectivity in the human brain. In this study, the behavior of an algorithm for white matter tractography is examined. The algorithm, called TEND, uses the entire diffusion tensor to deflect the estimated fiber trajectory. Simulations and imaging experiments on in vivo human brains were performed to investigate the behavior of the tractography algorithm. The simulations show that the deflection term is less sensitive than the major eigenvector to image noise. In the human brain imaging experiments, estimated tracts were generated in corpus callosum, corticospinal tract, internal capsule, corona radiata, superior longitudinal fasciculus, inferior longitudinal fasciculus, fronto-occipital fasciculus, and uncinate fasciculus. This approach is promising for mapping the organizational patterns of white matter in the human brain as well as mapping the relationship between major fiber trajectories and the location and extent of brain lesions.

Algorithms↗

Diffusion weighted magnetic resonance imaging in stroke.

Diffusion weighted magnetic resonance imaging has evolved from an esoteric laboratory experiment to a critical aspect of routine clinical care of the patient presenting with symptoms suspicious of acute ischemic stroke. The purpose of this article is to review the basis of diffusion weighted imaging (DWI), to consider its application in acute stroke and to recognize potential pitfalls and stroke mimics that might be encountered. Included in the discussion are comments on the elimination of 'T2 shine through' phenomena as well as construction of pixel-by-pixel maps of the apparent diffusion coefficient (ADC). Furthermore, discussion of techniques such as parallel imaging (using SENSE) and PROPELLER sequences will be introduced as methods potentially allowing DWI to be utilized in areas usually associated with prohibitive susceptibility artifact (e.g. the base of the brain). Finally, the concept of interventional therapeutic approaches to salvaging ischemic tissue is introduced, both in terms of the ischemic penumbra (defined by a diffusion/perfusion mismatch) and also in terms of the potential reversibility of the diffusion-weighted hyperintensity, associated with the lesion core.

Acute Disease↗

Consistency of interictal and ictal onset localization using magnetoencephalography in patients with partial epilepsy.

OBJECT: The aim of this study was to evaluate the spatial accuracy of interictal magnetoencephalography (MEG) in localizing the primary epileptogenic focus in comparison with alternative MEG-derived estimates such as ictal onset recording or sensory mapping of the periphery where seizures manifest. METHODS: During this retrospective study of 12 patients with epilepsy who had undergone successful magnetic source (MS) imaging with the aid of a dual 37-channel biomagnetometer as well as simultaneous MEG/electroencephalography (EEG) recordings, ictal events were observed in five patients and quantitative comparisons of interictal spike and ictal seizure onset source localizations were made. In the eight patients who had presented with sensorimotor seizure, source localization of cortical sites concordant with seizure foci was determined using somatosensory functional mapping, and the results were quantitatively compared with interictal spike source localizations. Interictal spike sources demonstrated on MEG localized to the same region as the corresponding ictal event or somatosensory source localizations. The mean distance between the ictal foci and interictal spike sources was 1.1 +/- 0.3 cm. Results of functional somatosensory mapping in patients with sensorimotor seizures demonstrated that seizure sources consistently colocalized with interictal MEG spike sources, with a mean distance of 1.5 +/- 0.4 cm. No systematic directional bias was observed. Interictal sources tended to be tightly clustered, and the mean ellipsoid volume, defined by one standard deviation of the source spatial coordinates, was 1 cm3. CONCLUSIONS: Interictal spike localizations on MEG were concordant with ictal and, where relevant, functional somatosensory mapping localizations. These findings support the interpretation of interictal spikes on MEG as a useful and effective noninvasive method for localizing primary seizure foci.

Adolescent↗

Three-dimensional high-resolution magnetic resonance imaging of ocular and orbital malignancies.

BACKGROUND: Ultrathin-section 3-dimensional fast spin-echo (3-D FSE) T2-weighted imaging is a new magnetic resonance imaging (MRI) technique that we used in the evaluation of ocular and orbital malignancies. We evaluated the usefulness of this new technique compared with conventional MRI. METHODS: Imaging data from 26 consecutive patients seen in the Ocular Oncology Unit at the University of California-San Francisco were retrospectively reviewed by physicians from the ocular oncology and neuroradiology units. For all patients, 3-D FSE T2-weighted images (27 scans) were compared with results of conventional MRI and correlated with results of computed tomography (CT), A- and B-scan ultrasonography, ultrasound biomicroscopy, clinical examinations, and histopathology, when available. RESULTS: The 3-D FSE T2-weighted imaging sequence resulted in an overall improvement in accuracy of imaging findings in 17 (63%) of our 27 cases compared with the standard MRI protocol. The increased resolution led to the radiographic detection of additional lesions in 11 (41%) of 27 cases and to an increase in confidence in radiographic diagnosis in 6 (22%) of the remaining cases. The improved resolution of the 3-D FSE T2-weighted sequence resulted in a change of disease management in 3 (60%) of the 5 patients with nonretinoblastoma lesions. One hundred percent of active retinoblastoma lesions could be detected by means of 3-D FSE and conventional imaging; however, inactive lesions were not always detected using conventional imaging. CONCLUSIONS: The 3-D FSE T2-weighted sequence offers superior resolution of intraocular and orbital structures compared with conventional MRI. It is particularly useful in the evaluation of intraocular tumors and the nerve-sheath complex. This new technique contributes significantly to improved diagnosis and management in patients with ocular and orbital malignancies.

Eye Neoplasms↗

Computed tomographic findings in patients undergoing intra-arterial thrombolysis for acute ischemic stroke due to middle cerebral artery occlusion: results from the PROACT II trial.

BACKGROUND AND PURPOSE: The purpose of this study was to evaluate the role of noncontrast CT in the selection of patients to receive thrombolytic therapy for acute ischemic stroke and to predict radiological and clinical outcomes. METHODS: One hundred eighty patients with stroke due to middle cerebral artery (MCA) occlusion were randomized 2:1 within 6 hours of onset to receive intra-arterial recombinant prourokinase plus intravenous heparin or intravenous heparin only. Four hundred fifty-four CT examinations were digitized to calculate early infarct changes, infarct volumes, and hemorrhagic changes among the 162 patients treated as randomized (108 recombinant prourokinase-treated patients and 54 control patients). CT changes were correlated with baseline stroke severity, angiographic clot location, collateral vessels, and outcome at 90 days. RESULTS: Baseline CT scans, 120 (75%) of 159, showed early infarct-related abnormalities. The baseline CT abnormality volume was not correlated with the baseline National Institutes of Health Stroke Scale (NIHSS) score (r=-0.11) but was correlated weakly with the outcome (r=0.17, P<0.05). Compared with patients with M2 occlusions, patients with M1 MCA occlusions had significantly higher baseline NIHSS scores (P<0.05), more basal ganglia involvement on CT, and larger hypodensity volumes on follow-up CTs. Compared with patients with partial or no collateral supply, patients with full collateral supply had lower baseline NIHSS scores, significantly smaller baseline CT infarct volumes, and less cortical involvement (P<0.05). CONCLUSIONS: Noncontrast CT is not correlated with baseline stroke severity and does not predict outcome in patients with stroke due to MCA occlusion. However, baseline CT changes, clinical presentation, and the evolution of CT changes are influenced by clot location and the presence of a collateral supply.

Acute Disease↗

Diffusion-tensor imaging of white matter tracts in patients with cerebral neoplasm.

OBJECT: Preserving vital cerebral function while maximizing tumor resection is a principal goal in surgical neurooncology. Although functional magnetic resonance imaging has been useful in the localization of eloquent cerebral cortex, this method does not provide information about the white matter tracts that may be involved in invasive, intrinsic brain tumors. Recently, diffusion-tensor (DT) imaging techniques have been used to map white matter tracts in the normal brain. The aim of this study was to demonstrate the role of DT imaging in preoperative mapping of white matter tracts in relation to cerebral neoplasms. METHODS: Nine patients with brain malignancies (one pilocytic astrocytoma, five oligodendrogliomas, one low-grade oligoastrocytoma, one Grade 4 astrocytoma, and one metastatic adenocarcinoma) underwent DT imaging examinations prior to tumor excision. Anatomical information about white matter tract location, orientation, and projections was obtained in every patient. Depending on the tumor type and location, evidence of white matter tract edema (two patients), infiltration (two patients), displacement (five patients), and disruption (two patients) could be assessed with the aid of DT imaging in each case. CONCLUSIONS: Diffusion-tensor imaging allowed for visualization of white matter tracts and was found to be beneficial in the surgical planning for patients with intrinsic brain tumors. The authors' experience with DT imaging indicates that anatomically intact fibers may be present in abnormal-appearing areas of the brain. Whether resection of these involved fibers results in subtle postoperative neurological deficits requires further systematic study.

Adenocarcinoma↗

Preoperative magnetic source imaging for brain tumor surgery: a quantitative comparison with intraoperative sensory and motor mapping.

OBJECT: The aim of this study was to compare quantitatively the methods of preoperative magnetic source (MS) imaging and intraoperative electrophysiological cortical mapping (ECM) in the localization of sensorimotor cortex in patients with intraaxial brain tumors. METHODS: Preoperative magnetoencephalography (MEG) was performed while patients received painless tactile somatosensory stimulation of the lip, hand, and foot. The early somatosensory evoked field was modeled using a single equivalent current dipole approach to estimate the spatial source of the response. Three-dimensional magnetic resonance image volume data sets with fiducials were coregistered with the MEG recordings to form the MS image. These individualized functional brain maps were integrated into a neuronavigation system. Intraoperative mapping of somatosensory and/or motor cortex was performed and sites were compared. In two subgroups of patients we compared intraoperative somatosensory and motor stimulation sites with MS imaging-based somatosensory localizations. Mediolateral projection of the MS imaging source localizations to the cortical surface reduced systematic intermodality discrepancies. The distance between two corresponding points determined using MS imaging and ECM was 12.5 +/- 1.3 mm for somatosensory-somatosensory and 19 +/- 1.3 mm for somatosensory-motor comparisons. The observed 6.5 mm increase in site separation was systematically demonstrated in the anteroposterior direction, as expected from actual anatomy. In fact, intraoperative sites at which stimulation evoked the same patient response exhibited a spatial variation of 10.7 +/- 0.7 mm. CONCLUSIONS: Preoperative MS imaging and intraoperative ECM show a favorable degree of quantitative correlation. Thus, MS imaging can be considered a valuable and accurate planning adjunct in the treatment of patients with intraaxial brain tumors.

Adolescent↗

Magnetic source imaging demonstrates altered cortical distribution of function in patients with arteriovenous malformations.

OBJECTIVE: Arteriovenous malformations (AVMs) can be treated successfully, but treatment can pose unacceptable risks if the AVM is located in eloquent cortex. Because AVMs are developmental lesions, the location of primary cortical function may be deranged. We used magnetic source imaging (MSI) to identify the central sulcus and to determine whether primary cortical function was shifted in a set of 30 patients. We correlated these findings with outcome after treatment. METHODS: We retrospectively analyzed the clinical data of 30 patients with AVMs who underwent MSI. Nonparametric statistical comparisons were made to correlate the proximity of AVMs to primary cortex and somatosensory shift to outcome at 12 months. RESULTS: Using MSI, 14 patients (47%) were found to have AVMs involving primary cortex, and 10 patients (33%) were found to have shift in the somatosensory homunculus. Primary cortical involvement was neither required nor sufficient to cause shift (Mann-Whitney U test, z = -0.02, P = 0.31). Patients with AVMs involving primary cortex fared worse after treatment than did patients with AVMs that spared primary cortex (Mann-Whitney U test, z = -2.3, P = 0.02). The presence or absence of shift did not correlate with outcome after treatment (Mann-Whitney U test, z = -0.18, P = 0.48). CONCLUSION: MSI showed that some patients with AVMs have abnormal cortical distribution of function. The involvement of primary cortex correlated with worse outcome after treatment. Our results suggest that preoperative functional imaging may help to better estimate treatment risks and ultimately to guide therapeutic planning.

Adolescent↗

Confounding effect of large vessels on MR perfusion images analyzed with independent component analysis.

BACKGROUND AND PURPOSE: First pass contrast-enhanced MR imaging using gradient-echo acquisitions is commonly used to assess cerebral blood flow, despite the confounding signal from large blood vessels. We hypothesized that removal of this unwanted intravascular signal using independent component analysis would result in a more accurate depiction of cerebral blood flow. METHODS: Images of 11 patients, acquired with our acute stroke imaging protocol, were post processed to produce images of relative cerebral blood flow (rCBF). The same images were processed with independent component analysis to identify and remove the signal from large blood vessels, with a second set of rCBF images produced. Both sets of rCBF maps were pooled, randomized in order, and read in a blinded fashion by two neuroradiologists to assess the level of large artery artifact and overall image quality. Significance was determined using a Wilcoxon signed rank test. RESULTS: Results from both readers indicated that the level of large artery artifact was significantly reduced in the images processed using independent component analysis component removal (P <.05). In addition, both readers indicated significantly (P <.05) improved image quality of the images processed using independent component analysis. CONCLUSION: The removal of the signal resulting from large blood vessels before calculation of rCBF resulted in images with significantly less artifact and higher image quality.

Adolescent↗