Validation of GATE Monte Carlo simulations of the GE Advance/Discovery LS PET scanners.

The recently developed GATE (GEANT4 application for tomographic emission) Monte Carlo package, designed to simulate positron emission tomography (PET) and single photon emission computed tomography (SPECT) scanners, provides the ability to model and account for the effects of photon noncollinearity, off-axis detector penetration, detector size and response, positron range, photon scatter, and patient motion on the resolution and quality of PET images. The objective of this study is to validate a model within GATE of the General Electric (GE) Advance/Discovery Light Speed (LS) PET scanner. Our three-dimensional PET simulation model of the scanner consists of 12 096 detectors grouped into blocks, which are grouped into modules as per the vendor's specifications. The GATE results are compared to experimental data obtained in accordance with the National Electrical Manufactures Association/Society of Nuclear Medicine (NEMA/SNM), NEMA NU 2-1994, and NEMA NU 2-2001 protocols. The respective phantoms are also accurately modeled thus allowing us to simulate the sensitivity, scatter fraction, count rate performance, and spatial resolution. In-house software was developed to produce and analyze sinograms from the simulated data. With our model of the GE Advance/Discovery LS PET scanner, the ratio of the sensitivities with sources radially offset 0 and 10 cm from the scanner's main axis are reproduced to within 1% of measurements. Similarly, the simulated scatter fraction for the NEMA NU 2-2001 phantom agrees to within less than 3% of measured values (the measured scatter fractions are 44.8% and 40.9 +/- 1.4% and the simulated scatter fraction is 43.5 +/- 0.3%). The simulated count rate curves were made to match the experimental curves by using deadtimes as fit parameters. This resulted in deadtime values of 625 and 332 ns at the Block and Coincidence levels, respectively. The experimental peak true count rate of 139.0 kcps and the peak activity concentration of 21.5 kBq/cc were matched by the simulated results to within 0.5% and 0.1% respectively. The simulated count rate curves also resulted in a peak NECR of 35.2 kcps at 10.8 kBq/cc compared to 37.6 kcps at 10.0 kBq/cc from averaged experimental values. The spatial resolution of the simulated scanner matched the experimental results to within 0.2 mm.

Algorithms↗

Intensity-modulated radiotherapy as the boost or salvage treatment of nasopharyngeal carcinoma: the appropriate parameters in the inverse planning and the effect of patient's anatomic factors on the planning results.

The current study demonstrates that the large increase in normal tissue penalty often degrades target dose uniformity without a concomitant large improvement in normal tissue dose, especially in anatomically unfavorable patients. The excessively large normal tissue penalties do not improve treatment plans for patients having unfavorable geometry.

Carcinoma↗

CT image-guided intensity-modulated therapy for paraspinal tumors using stereotactic immobilization.

PURPOSE: To design and implement a noninvasive stereotactic immobilization technique with daily CT image-guided positioning to treat patients with paraspinal lesions accurately and to quantify the systematic and random patient setup errors occurring with this method. METHODS AND MATERIALS: A stereotactic body frame (SBF) was developed for "rigid" immobilization of paraspinal patients. The inherent accuracy of this system for stereotactic CT-guided treatment was evaluated with phantom studies. Seven patients with thoracic and lumbar spine lesions were immobilized with the SBF and positioned for 33 treatment fractions using daily CT scans. For all 7 patients, the daily setup errors, as assessed from the daily CT scans, were corrected at each treatment fraction. A retrospective analysis was also performed to assess what the impact on patient treatment would have been without the CT-based corrections (i.e., if patient setup had been performed only with the SBF). RESULTS: The average magnitude of systematic and random errors from uncorrected patient setups using the SBF was approximately 2 mm and 1.5 mm (1 SD), respectively. For fixed phantom targets, the system accuracy for the SBF localization and treatment was shown to be within 1 mm (1 SD) in any direction. Dose-volume histograms incorporating these uncertainties for an intensity-modulated radiotherapy plan for lumbar spine lesions were generated, and the effects on the dose-volume histograms were studied. CONCLUSION: We demonstrated a very accurate and precise method of patient immobilization and treatment delivery based on a noninvasive SBF and daily image guidance for paraspinal lesions. The SBF provides excellent immobilization for paraspinal targets, with setup accuracy better than 2 mm (1 SD). However, for highly conformal paraspinal treatments, uncorrected systematic and random errors of 2 mm in magnitude can result in a significantly greater (>100%) dose to the spinal cord than planned, even though the planned target coverage may not change substantially. With daily CT guidance using the SBF, we showed that the maximal spinal cord dose is ensured to be within 10-15% of the planned value.

Humans↗

Technological advances in external-beam radiation therapy for the treatment of localized prostate cancer.

The relative inability of conventional radiotherapy to control localized prostate cancer results from resistance of subpopulations of tumor clonogens to dose levels of 65 to 70 Gy, the maximum feasible with traditional two-dimensional (2D) treatment planning and delivery techniques. Several technological advances have enhanced the precision and improved the outcome of external-beam radiotherapy. The three-dimensional conformal radiotherapy (3D-CRT) approach has permitted significant increases in the tumor dose to levels beyond those feasible with conventional techniques. Intensity-modulated radiotherapy (IMRT), an advanced form of conformal radiotherapy, has resulted in reduced rectal toxicity, permitting tumor dose escalation to previously unattainable levels with a concomitant improvement in local tumor control and disease-free survival. The combination of androgen deprivation and conventional-dose radiotherapy, tested mainly in patients with locally advanced disease, has also produced significant outcome improvements. Whether androgen deprivation will preclude the need for dose escalation or whether high-dose radiotherapy will obviate the need for androgen deprivation remains unknown. In some patients, both approaches may be necessary to maximize the probability of cure. In view of the favorable benefit-risk ratio of high-dose IMRT, the design of clinical trials to resolve these critical questions is essential.

Actuarial Analysis↗

Evaluation of concave dose distributions created using an inverse planning system.

PURPOSE: To evaluate and develop optimum inverse treatment planning strategies for the treatment of concave targets adjacent to normal tissue structures. METHODS AND MATERIALS: Optimized dose distributions were designed using an idealized geometry consisting of a cylindrical phantom with a concave kidney-shaped target (PTV) and cylindrical normal tissues (NT) placed 5-13 mm from the target. Targets with radii of curvature from 1 to 2.75 cm were paired with normal tissues with radii between 0.5 and 2.25 cm. The target was constrained to a prescription dose of 100% and minimum and maximum doses of 95% and 105% with relative penalties of 25. Maximum dose constraint parameters for the NT varied from 10% to 70% with penalties from 10 to 1000. Plans were evaluated using the PTV uniformity index (PTV D(max)/PTV D(95)) and maximum normal tissue doses (NT D(max)/PTV D(95)). RESULTS: In nearly all situations, the achievable PTV uniformity index and the maximum NT dose exceeded the corresponding constraints. This was particularly true for small PTV-NT separations (5-8 mm) or strict NT dose constraints (10%-30%), where the achievable doses differed from the requested by 30% or more. The same constraint parameters applied to different PTV-NT separations yielded different dose distributions. For most geometries, a range of constraints could be identified that would lead to acceptable plans. The optimization results were fairly independent of beam energy and radius of curvature, but improved as the number of beams increased, particularly for small PTV-NT separations or strict dose constraints. CONCLUSION: Optimized dose distributions are strongly affected by both the constraint parameters and target-normal tissue geometry. Standard site-specific constraint templates can serve as a starting point for optimization, but the final constraints must be determined iteratively for individual patients. A strategy whereby NT constraints and penalties are modified until the highest acceptable PTV uniformity index is achieved is discussed. This strategy can be used, in simple patient geometries, to ensure the lowest possible normal tissue dose. Strategies for setting the optimum dose constraints and penalties may vary for different optimization algorithms and objective functions. Increasing the number of beams can significantly improve normal tissue dose and target uniformity in situations where the PTV-NT separation is small or the normal tissue dose limits are severe. Setting unrealistically severe constraints in such situations often results in dose distributions that are inferior to plans achieved with more lenient constraints.

Algorithms↗

Intensity-modulated radiotherapy versus conventional three-dimensional conformal radiotherapy for boost or salvage treatment of nasopharyngeal carcinoma.

PURPOSE: To compare intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy (3D-CRT) for the boost treatment of new-onset nasopharyngeal carcinoma (NPC) or the salvage treatment of locally recurrent NPC. METHODS AND MATERIALS: Between January 14 and February 23, 2000, 5-field 3D-CRT treatment plans were generated for 14 consecutive NPC patients using the ADAC Pinnacle planning system in Chang Gung Memorial Hospital, Kaohsiung, Taiwan. The planning data of these patients were later transferred to Memorial Sloan-Kettering Cancer Center, where new IMRT plans, also using 5-7 radiation fields were created for each patient using an inverse treatment planning system. The IMRT and 3D-CRT plans were compared for all 14 patients. The relationship between the anatomic shapes and locations of targets and the results of different plans were studied. RESULTS: Target doses were more homogeneous in IMRT plans. The average maximal brainstem dose (D(05), the dose received by 5% of the brainstem volume) decreased from 30.9% of the prescription dose with 3D-CRT to 15.3% and 14.7% with 5- and 7-field IMRT, respectively (p = 0.004 and 0.003, respectively, compared with 3D-CRT, paired Student's t test). Five anatomic factors were found that predicted greater benefits with IMRT. These factors were (1) vertical length of target >7 cm, (2) minimal distance between target and brainstem <0.1 cm, (3) maximal AP overlap of target and brainstem >0.6 cm, (4) maximal AP overlap of target and spinal cord >1 cm, and (5) vertical overlap of target and eyes >0 cm. For the 7 patients with at least 1 of these 5 anatomic factors, the benefits achieved by IMRT planning would have been greater than the benefits for the other 7 patients (p = 0.005, Fisher's exact test). CONCLUSION: For boost or salvage treatment of NPC, lower normal tissue doses and more homogeneous target doses were achieved with IMRT plans. For NPC patients with at least 1 of the 5 anatomic factors, IMRT is highly recommended.

Algorithms↗

The Anderson nomograms for permanent interstitial prostate implants: a briefing for practitioners.

PURPOSE: The objective of this report is to re-evaluate the role of the Anderson nomograms in treatment planning for permanent prostate implants. The incentive for revisiting this topic concerns three issues: (1) Although nomograms continue to be used in many centers for ordering seeds, few centers use them during treatment planning; (2) Whereas nomograms were designed to deliver a minimum peripheral dose for a uniform distribution of seeds in the gland, many practitioners use peripheral seed loading patterns to reduce urethral toxicity; and (3) As preoperative and intraoperative treatment planning is becoming standard, the apparent role of nomograms is diminished. The nomogram method is reviewed in terms of: (1) total activity predicted, (2) target coverage (as planned in the operating room and as calculated from postimplant computed tomography studies), and (3) reproducibility (i.e., patient-to-patient and planner-to-planner variability). In each case, the computer-optimization system for intraoperative planning currently in use at our institution was taken as the "gold standard." METHODS AND MATERIALS: We compared for the same patient the results of nomogram planning to those yielded by genetic algorithm (GA) optimization in terms of total activity predicted (n = 20 cases) and percent target coverage (n = 5 cases). Furthermore, we examined retrospectively the dosimetry of 61 prostate implants planned with the GA (n = 27) and the current implementation of Anderson nomograms (n = 34). RESULTS: Nomogram predictions of the total activity required are in good agreement (within 10%) with the GA-planned activity. However, computer-optimized plans consistently yield superior plans, as reflected in both pre- and postimplant analyses. We find also that user (specifically, treatment planner) implementation of the nomograms may be a major source of variability in nomogram planning-a difficulty to which robust computer optimization is less prone. CONCLUSIONS: Nomograms continue to be useful tools for predicting the total required activity for volume implants, and thus for performing an independent check of this quantity. Not unexpectedly, computer optimization remains the preferred planning method. Generally, nomogram-guided implants do not incorporate structures other than the treatment volume into the planning process. Further yet, they deliver a lower dose than that prescribed and result in greater variability among plans than computer-optimized treatments. In summary, nomograms (1) remain an efficient quality assurance tool for computer-generated plans, (2) serve as a good predictor of the number of seeds required for ordering purposes, and (3) provide a simple and dependable backup planning method in case the intraoperative planning system fails.

Algorithms↗

EUD but not QED.

Explore the source record for details and available documents.

Humans↗

Optimized planning for intraoperative planar permanent-seed implant.

We describe a fast, PC-based optimization planning system for a planar permanent-seed implant. Sites where this system is applicable include brain, lung, and head and neck. The system described here allows placing ribbons of different strengths and of different lengths along and across the implant plane. The program takes full advantage of the availability of different source strengths in inventory, and attempts to find configurations of ribbons that result in optimal dose uniformity over the prescription plane. Dosimetry is based on the AAPM TG 43 Report [R. Nath et al., Med. Phys. 22, 209-234 (1995)]. Compared with TG 43 parameters, the classical tables underestimate the I-125 source strengths needed by 40%. The use of several source strengths improves the plan. Typical optimization yields dose uniformity of 10%, and computing times are within 2-3 min. No further enhancement is obtained if ribbons are placed in a grid pattern as opposed to the (simpler) arrangement along parallel lines. Nor is it valuable to have variable ribbon lengths. For an I-125 implant the optimization system described here is a practical alternative to the (strictly speaking inapplicable) classical systems. It calculates correctly the total source strengths, and--most notably--generates plans with optimal dose uniformity. The fast computing time is well suited for planning during surgery in the operating room.

Brain Neoplasms↗

Intensity-modulated radiotherapy.

Intensity-modulated radiotherapy represents a recent advancement in conformal radiotherapy. It employs specialized computer-driven technology to generate dose distributions that conform to tumor targets with extremely high precision. Treatment planning is based on inverse planning algorithms and iterative computer-driven optimization to generate treatment fields with varying intensities across the beam section. Combinations of intensity-modulated fields produce custom-tailored conformal dose distributions around the tumor, with steep dose gradients at the transition to adjacent normal tissues. Thus far, data have demonstrated improved precision of tumor targeting in carcinomas of the prostate, head and neck, thyroid, breast, and lung, as well as in gynecologic, brain, and paraspinal tumors and soft tissue sarcomas. In prostate cancer, intensity-modulated radiotherapy has resulted in reduced rectal toxicity and has permitted tumor dose escalation to previously unattainable levels. This experience indicates that intensity-modulated radiotherapy represents a significant advancement in the ability to deliver the high radiation doses that appear to be required to improve the local cure of several types of tumors. The integration of new methods of biologically based imaging into treatment planning is being explored to identify tumor foci with phenotypic expressions of radiation resistance, which would likely require high-dose treatments. Intensity-modulated radiotherapy provides an approach for differential dose painting to selectively increase the dose to specific tumor-bearing regions. The implementation of biologic evaluation of tumor sensitivity, in addition to methods that improve target delineation and dose delivery, represents a new dimension in intensity-modulated radiotherapy research.

Abdominal Neoplasms↗