PubMed Health⌕ Search

Biomedical subjects

Hubert H Girault

Publications and source records attributed to Hubert H Girault.

At least 19 recordsLinked to original sources

Supercapacitive admittance tomoscopy.

A sensor for measuring adsorption on a substrate has been designed including a contactless detection scheme, called supercapacitive admittance tomoscopy (SCAT). The sensor comprises a thin dielectric layer with two parallel band electrodes on the one side and a chemically modified surface on the other onto which the adsorption of molecules occurs. Upon application of a high frequency ac voltage between the two electrodes, a capacitive coupling is established across the dielectric layer, and the admittance measured depends on the surface state of the chemically modified interface. On the basis of this principle, a flow sensor has been developed to measure sensorgrams to follow the dynamics of the adsorption and has been tested for the adsorption of IgG on the modified surface.

Adsorption↗

Dynamic protein adsorption in microchannels by "stop-flow" and continuous flow.

This work addresses two ways of loading proteins on microchannel surfaces for immunoassay applications: the "stop-flow" and the continuous flow processes. The "stop-flow" method consists of successive static incubation periods where the bulk solution depletes upon the adsorption process. In the present paper, a multi-step "stop-flow" protein coating is studied and compared to a coating under continuous flow conditions. For the "stop-flow", a non-dimensional parameter is here introduced, indicating the adsorbing capacity of the system, by which it is possible to calculate the number of loads necessary to reach the optimum coverage. For the continuous flow, the effects on the adsorption of the kinetic rates, flow velocity and wall capacity have been considered. This study shows the importance of a careful choice of the fluid velocity to minimise the sample waste. For diffusion controlled and kinetics controlled processes, two flow velocity criteria are provided in order to obtain the best possible coverage, with the same amount of sample as with the "stop-flow".

Adsorption↗

Reactivity of monolayer-protected gold nanoclusters at dye-sensitized liquid/liquid interfaces.

Hexanethiolate monolayer-protected gold nanoclusters (MPCs) were used as redox quenchers at the polarizable water/1,2-dichloroethane (DCE) interface. Photocurrent responses originating from the heterogeneous quenching of photoexcited water soluble porphyrin complexes by MPCs dissolved in the DCE phase were observed. As MPCs can function as both electron acceptors and donors, the photocurrent results from the superposition of two simultaneous processes, which correspond to the oxidation and reduction of MPCs. The magnitude of the net photocurrent is essentially determined by the balance of the kinetics of these two processes, which can be controlled by tuning the Galvani potential difference between the two phases. We show that, within the available potential window, the apparent electron-transfer rate constants follow classical Butler-Volmer dependence on the applied potential difference.

Journal Article↗

Numerical simulation of two-phase partition chromatography in microchannels for moderated log P measurements.

A finite element simulation has been used in order to study the partition chromatography process of one species between an aqueous mobile phase and an organic stationary phase located at the bottom of a rectangular microchannel. The transient model incorporates convection--diffusion of the species in the water phase coupled to the diffusion in the stationary organic phase by the way of the partition kinetics at the interface. The time evolution of the injected species concentration is analyzed versus the velocity of the mobile phase, the detecting position and the thickness of the stationary phase. The comparison of simulation results with both experimental data and analytical model confirm its validity. These simulations show that thin channels can be used to measure log P of molecules from their retention time. Finally, we have shown how the sample velocity can be optimized for a given geometry of the channel and diffusion coefficient of the species.

Calibration↗

On-line counting of cysteine residues in peptides during electrospray ionization by electrogenerated tags and their application to protein identification.

The electrochemically induced mass spectrometric tagging of cysteines by substituted hydroquinones was studied for peptides in a classical electrospray solvent (i.e., MeOH/H2O/AcOH 50/49/1). The tagging efficiency was tested with different hydroquinone compounds on an undecapeptide containing one cysteine residue. 2-carboxymethylhydroquinone was the most reactive probe and revealed to be suitable for cysteine quantification in peptides containing up to three cysteine residues, even in the case of two consecutive cysteines in the sequence. We demonstrate the compatibility of the on-line electrochemical tagging method for the cysteine content analysis of peptides coming from gel-free protein digestion procedures. The identification of bovine serum albumin and human alpha-lactalbumin digest samples in a peptide mapping strategy was greatly improved by the application of the electrotagging technique as post-column treatment. Indeed, the determination of cysteine content in the tryptic peptides provided powerful information in order to enhance the identification score as well as the discrimination against other protein candidates. The tagging method was then applied to the determination of four proteins in a model mixture.

Animals↗

Salt removal during Off-Gel electrophoresis of protein samples.

The Off-Gel technology was recently described for protein fractionation in a solution placed on top of an immobilized pH gradient gel. In addition, this process was found to remove salts from the biological samples to analyze. This desalting effect is studied experimentally in a conductometric prototype cell. A simplified analytical model is developed to understand this process and a good agreement is found with the conductivity measurements. To illustrate the desalting of a biological sample, a 1 mg.mL(-1) solution of beta-lactoglobulin A in 0.1 M NaCl is subjected to electrophoresis in a single compartment Off-Gel cell. The analysis of the resulting sample by ESI-MS demonstrates the effective removal of salt. A finite element diffusion-migration model is also used to illustrate how the nonuniformity of the electric field in the cell, associated with the salt migration, can slow down the desalting process.

Electric Conductivity↗

Chip electrospray mass spectrometry for carbohydrate analysis.

Currently two types of chip systems are used in conjunction with MS: out-of-plane devices, where hundreds of nozzles, nanospray emitters are integrated onto a single silicon substrate from which electrospray is established perpendicular to the substrate, and planar microchips, embedding a microchannel at the end of which electrospray is generated in-plane, on the edge of the microchip. In the last two years, carbohydrate research greatly benefited from the introduction and implementation of the chip-based MS. In two laboratories the advantages of the chip electrospray in terms of ionization efficiency, sensitivity, reproducibility, quality of data in combination with high mass accuracy, and resolution of detection were systematically explored for several carbohydrate classes: O- and N-glycopeptides, oligosaccharides, gangliosides and glycoprotein-derived O- and N-glycans, and glycopeptides. The current state-of-the-art in interfacing the chip electrospray devices to high-performance MS for carbohydrate analysis, and the particular requirements for method optimization in both positive and negative ion modes are reviewed here. The recent applications of these miniaturized devices and their general potential for glycomic-based surveys are highlighted.

Amino Acid Sequence↗

Study of peptide on-line complexation with transition-metal ions generated from sacrificial electrodes in thin-chip polymer microsprays.

A miniaturized polymer electrospray-type interface is used to study metal-ion chelation with model peptides. Taking advantage of the intrinsic electrochemical behavior of electrospray, a sacrificial electrode is used to generate at the same time electrospray and transition-metal ions coming from the anodic dissolution of the electrode. The microspray interface provides enhanced mass transport due to its small dimensions, increasing the yield of possible reactions, in particular complex formation. Transition-metal electrodes, e.g. copper, zinc, nickel, iron and silver, are used to obtain on-line complexation with model peptides. It is demonstrated that the use of in-reservoir sacrificial electrodes is an efficient way to generate metal ions in order to form and study complexes with peptides, avoiding the addition of metallic salts.

Angiotensin II↗

Thin chip microsprayer system coupled to quadrupole time-of-flight mass spectrometer for glycoconjugate analysis.

A thin chip polymer-based microsprayer has been coupled to a hybrid quadrupole time-of-flight mass spectrometer (QTOF MS) and introduced in carbohydrate research. The feasibility of the approach is demonstrated for mapping, sequencing and structural elucidation of glycoconjugates originating from human body fluids and tissues such as a glycopeptide mixture from normal human urine and an isolated and purified GT1 ganglioside fraction from normal adult human brain. The optimization procedure required by each glycoconjugate category is described and the advantages of the system in terms of flexibility and adaptability to QTOF MS, stability of the ESI MS signal, carbohydrate ionization and sequencing, sensitivity, speed of analysis and sample consumption are discussed.

Amino Acids↗

Size-selective separation of gold nanoparticles using isoelectric focusing electrophoresis (IEF).

Isoelectric focusing in a polyacrylamide pH gradient gel is used to analyze the size distribution of gold nanoparticles synthesized by a chemical route with mercaptosuccinic acid as a ligand. The isoelectric point of the nanoparticles is shown to be size dependent, allowing fractionation by electrophoresis. Each fraction has a narrow size distribution with a standard deviation lower than 0.4 nm.

Journal Article↗

Pure surface plasmon resonance enhancement of the first hyperpolarizability of gold core-silver shell nanoparticles.

We report the optical second harmonic (SH) response from gold core-silver shell nanoparticles supported at a liquid-liquid interface in the spectral region where the second harmonic generation (SHG) frequency is resonant with the surface plasmon (SP) resonance excitation of the nanoparticles. We compare these results with that obtained by classical linear optical absorption spectroscopy and show that the nonlinear optical response is dominated by the SP resonance enhancement with negligible contributions from the interband transitions. As a result, the SH spectrum exhibits two clear SP resonance bands attributed to the two SP resonances of the composite nanostructure formed by the gold core-silver shell nanoparticles. Absolute values of the hyperpolarizabilities are measured by hyper Rayleigh scattering (HRS) and compared that of pure gold nanoparticles. The hyperpolarizability measured at a harmonic energy of 3.0 eV, enhanced through excitation of the high energy SP resonance of the nanoparticle, increases with the silver content whereas the hyperpolarizability measured at a harmonic energy of 2.4 eV, enhanced through the excitation of the low energy SP resonance of the nanoparticle, decreases because of the shift of this resonance away from the harmonic frequency. The hyperpolarizability determined by HRS and the square root of the SHG intensities, scaling with the nanoparticle hyperpolarizability, have similar trends with respect to the silver content indicative of closely related adsorption properties yielding similar surface concentrations at the liquid-liquid interface.

Journal Article↗

Protein adsorption in static microsystems: effect of the surface to volume ratio.

A numerical model for the adsorption kinetics of proteins on the walls of a microchannel has been developed using the finite element method (FEM) to address the coupling with diffusion phenomena in the restricted microchannel volume. Time evolutions of the concentration of one species are given, both in solution and on the microchannel walls. The model illustrates the adsorption limitation sometimes observed when the microdimensions of these systems induce a global depletion of the bulk solution. A new non-dimensional parameter is introduced to predict the final value of the coverage of any microsystem under static adsorption. A working curve and a criteria (h/K[Gamma](max) > 10) are provided in order to choose, for given adsorption characteristics, the value of the volume-to-surface ratio (i.e. the channel height h) avoiding depletion effects on the coverage (relative coverage greater than 90% of the theoretical one). Simulations were compared with confocal microscopy measurements of IgG antibody adsorption on the walls of a PET microchannel. The fit of the model to the experimental data show that the adsorption is under apparent kinetic control.

Adsorption↗

A flexible sample introduction method for polymer microfluidic chips using a push/pull pressure pump.

A push/pull sample introduction method based on push/pull pressure flow for microfluidic systems (cross, double T and multichannel structures) is presented. This leads to well-defined and controllable sample plugs even when dealing with long channels. By tuning the relative push/pull pressure, it is shown that the size of the sample plug can effectively be controlled. Good signal reproducibility upon continued sample introduction and subsequent chip electrophoresis employing fluorescence detection is demonstrated for different chip geometries (i.e. short channels and long channels). Since the performance of the method is relatively insensitive to chip geometry, it is particularly useful for polymeric prototype microchips as tedious optimization is not required. Furthermore, the push/pull sample introduction is extended to multichannel chips thus demonstrating the possibilities of applying the methodology for realizing single chip high throughput sample analysis.

Equipment Design↗

Effect of the phase volume ratio on the potential of a liquid-membrane ion-selective electrode.

Two-phase liquid system IA(w)|IX(o) comprising the interface between the aqueous solution (w) of uni-univalent electrolyte IA and an organic solvent solution (o) of a uni-univalent electrolyte IX with the common cation I(+) is considered as a simple model of a liquid-membrane ion-selective electrode (ISE). Taking into account the electroneutrality and mass balance conditions, the equilibrium Galvani potential difference (pd) between the aqueous and organic phases, phi = phi(w) - phi(o), is calculated numerically as a function of the ratio of the initial electrolyte concentrations, x = / = 10(-)(4)-10(4), for the selected values of the phase volume ratio r = V(o)/V(w) = 10(-)(3), 1, and 10(3), and the standard ion transfer potentials of the present ions ranging from -0.5 to 0.5 V. Numeric results corroborate the symbolic expressions derived for the cases when X(-) and A(-) are extremely lipophilic and hydrophilic ions, respectively, or when the concentration ratio x is extremely large or small. In contrast to the extraction system, where both electrolytes are initially present in the aqueous phase, the effect of the phase volume ratio on the equilibrium pd in the ISE model is rather weak, unless the counterions X(-) and A(-) differ little in their lipophilicity from the target ion I(+). It is shown that both the ISE and extraction model exhibit the Nernstian behavior only in a limited range of the concentration ratio x depending on the value of the standard ion transfer potentials of the counterions. When this ratio is extremely large or small, equilibrium pd approaches the limiting value given by the distribution potential of the electrolyte IA or IX, respectively. Similar conclusions can be drawn for the two-phase liquid system AI(w)|XI(o) with the common anion I(-).

Journal Article↗

Passive conductivity detection for capillary electrophoresis.

A passive electrochemical detection principle that can be applied to capillary electrophoresis is presented. The separation electrical field is used to generate a potential difference between two electrodes located along the channel. For constant-current electrophoresis, the generated signal is proportional to the resistance of the solution passing between the two electrodes. Contrary to conductivity detectors that are ac driven and need to be decoupled from the separation field, the passive detection directly takes advantage of the separation field. The signal is simply measured by a high-impedance voltmeter. The detection concept has been validated by numerical simulations showing how the magnitude of the signal is related to the ratio between the electrode distance and the length of the sample plug. As a proof of the principle, this detection concept has been demonstrated by the electrophoretic separation of three alkali ions on a polymer microchip. Based on preliminary results, a detection limit of 20 microM and a dynamic range of up to 3 orders of magnitude have been achieved.

Journal Article↗

Ultrafast chemical interface scattering as an additional decay channel for nascent nonthermal electrons in small metal nanoparticles.

The use of 4.2 nm gold nanoparticles wrapped in an adsorbates shell and embedded in a TiO2 metal oxide matrix gives the opportunity to investigate ultrafast electron-electron scattering dynamics in combination with electronic surface phenomena via the surface plasmon lifetimes. These gold nanoparticles (NPs) exhibit a large nonclassical broadening of the surface plasmon band, which is attributed to a chemical interface damping. The acceleration of the loss of surface plasmon phase coherence indicates that the energy and the momentum of the collective electrons can be dissipated into electronic affinity levels of adsorbates. As a result of the preparation process, gold NPs are wrapped in a shell of sulfate compounds that gives rise to a large density of interfacial molecules confined between Au and TiO2, as revealed by Fourier-transform-infrared spectroscopy. A detailed analysis of the transient absorption spectra obtained by broadband femtosecond transient absorption spectroscopy allows separating electron-electron and electron-phonon interaction. Internal thermalization times (electron-electron scattering) are determined by probing the decay of nascent nonthermal electrons (NNEs) and the build-up of the Fermi-Dirac electron distribution, giving time constants of 540 to 760 fs at 0.42 and 0.34 eV from the Fermi level, respectively. Comparison with literature data reveals that lifetimes of NNEs measured for these small gold NPs are more than four times longer than for silver NPs with similar sizes. The surprisingly long internal thermalization time is attributed to an additional decay mechanism (besides the classical e-e scattering) for the energy loss of NNEs, identified as the ultrafast chemical interface scattering process. NNEs experience an inelastic resonant scattering process into unoccupied electronic states of adsorbates, that directly act as an efficient heat bath, via the excitation of molecular vibrational modes. The two-temperature model is no longer valid for this system because of (i) the temporal overlap between the internal and external thermalization process is very important; (ii) a part of the photonic energy is directly transferred toward the adsorbates (not among "cold" conduction band electrons). These findings have important consequence for femtochemistry on metal surfaces since they show that reactions can be initiated by nascent nonthermal electrons (as photoexcited, out of a Fermi-Dirac distribution) besides of the hot electron gas.

Journal Article↗

Reversible voltage-induced assembly of au nanoparticles at liquid/liquid interfaces.

The voltage-induced assembly of mercaptosuccinic acid-stabilized Au nanoparticles of 1.5 +/- 0.4 nm diameter is investigated at the polarizable water/1,2-dichloroethane interface. Admittance measurements and quasi-elastic laser scattering (QELS) studies reveal that the surface concentration of the nanoparticle at the liquid/liquid boundary is reversibly controlled by the applied bias potential. The electrochemical and optical measurements provide no evidence of irreversible aggregation or deposition of the particles at the interface. Analysis of the electrocapillary curves constructed from the dependence of the frequency of the capillary waves on the applied potential and bulk particle concentration indicates that the maximum particle surface density is 3.8 x 10(13) cm(-2), which corresponds to 67% of a square closed-pack arrangement. This system provides a unique example of reversible assembly of nanostructures at interfaces, in which the density can be effectively tuned by the applied potential bias.

Journal Article↗