Time-resolved diffuse optical tomographic imaging for the provision of both anatomical and functional information about biological tissue.

We present in vivo images of near-infrared (NIR) diffuse optical tomography (DOT) of human lower legs and forearm to validate the dual functions of a time-resolved (TR) NIR DOT in clinical diagnosis, i.e., to provide anatomical and functional information simultaneously. The NIR DOT system is composed of time-correlated single-photon-counting channels, and the image reconstruction algorithm is based on the modified generalized pulsed spectral technique, which effectively incorporates the TR data with reasonable computation time. The reconstructed scattering images of both the lower legs and the forearm revealed their anatomies, in which the bones were clearly distinguished from the muscles. In the absorption images, some of the blood vessels were observable. In the functional imaging, a subject was requested to do handgripping exercise to stimulate physiological changes in the forearm tissue. The images of oxyhemoglobin, deoxyhemoglobin, and total hemoglobin concentration changes in the forearm were obtained from the differential images of the absorption at three wavelengths between the exercise and the rest states, which were reconstructed with a differential imaging scheme. These images showed increases in both blood volume and oxyhemoglobin concentration in the arteries and simultaneously showed hypoxia in the corresponding muscles. All the results have demonstrated the capability of TR NIR DOT by reconstruction of the absolute images of the scattering and the absorption with a high spatial resolution that finally provided both the anatomical and functional information inside bulky biological tissues.

Algorithms↗

Optical tomographic mapping of cerebral haemodynamics by means of time-domain detection: methodology and phantom validation.

One of the primary applications of diffuse optical imaging is to localize and quantify the changes in the cerebral oxygenation during functional brain activation. Up to now, data from an optical imager are simply presented as a two-dimensional (2D) topographic map using the modified Beer-Lambert law that assumes homogeneous optical properties beneath each optode. Due to the highly heterogeneous nature of the optical properties in the brain, the assumption is evidently invalid, leading to both low spatial resolution and inaccurate quantification in the assessment of haemodynamic changes. To cope with these difficulties, we propose a nonlinear tomographic image reconstruction algorithm for a two-layered slab geometry that uses time-resolved reflected light. The algorithm is based on the previously developed generalized pulse spectrum technique, and implemented within a semi-three-dimensional (3D) framework to conform to the topographic visualization and to reduce computational load. We demonstrate the advantages of the algorithm in quantifying simulated changes in haemoglobin concentrations and investigate its robustness to the uncertainties in the cortical structure and optical properties, as well as the effects of random noises on image quality. The methodology is also validated by experiments using a solid layered phantom.

Algorithms↗

Semi-three-dimensional algorithm for time-resolved diffuse optical tomography by use of the generalized pulse spectrum technique.

Although a foil three-dimensional (3-D) reconstruction with both 3-D forward and inverse models provide, the optimal solution for diffuse optical tomography (DOT), because of the 3-D nature of photon diffusion in tissue, it is computationally costly for both memory requirement and execution time in a conventional computing environment. Thus in practice there is motivation to develop an image reconstruction algorithm with dimensional reduction based on some modeling approximations. Here we have implemented a semi-3-D modified generalized pulse spectrum technique for time-resolved DOT, where a two-dimensional (2-D) distribution of optical properties is approximately assumed, while we retain 3-D distribution of photon migration in tissue. We have validated the proposed algorithm by reconstructing 3-D structural test objects from both numerically simulated and experimental date. We demonstrate our algorithm by comparing it with the calibrated 2-D reconstruction that is in widespread use as a shortcut to 3-D imaging and proving that the semi-3-D algorithm outperforms the calibrated 2-D algorithm.

Algorithms↗

Maps of optical differential pathlength factor of human adult forehead, somatosensory motor and occipital regions at multi-wavelengths in NIR.

The optical differential pathlength factor (DPF) is an important parameter for physiological measurement using near infrared spectroscopy, but for the human adult head it has been available only for the forehead. Here we report measured DPF results for the forehead, somatosensory motor and occipital regions from measurements on 11 adult volunteers using a time-resolved optical imaging system. The optode separation was about 30 mm and the wavelengths used were 759 nm, 799 nm and 834 nm. Measured DPFs were 7.25 for the central forehead and 6.25 for the temple region at 799 nm. For the central somatosensory and occipital areas (10 mm above the inion), DPFs at 799 nm are 7.5 and 8.75, respectively. Less than 10% decreases of DPF for all these regions were observed when the wavelength increased from 759 nm to 834 nm. To compare these DPF maps with the anatomical structure of the head, a Monte Carlo simulation was carried out to calculate DPF for these regions by using a two-layered semi-infinite model and assuming the thickness of the upper layer to be the sum of the thicknesses of scalp and skull, which was measured from MRI images of a subject's head. The DPF data will be useful for quantitative monitoring of the haemodynamic changes occurring in adult heads.

Brain↗

Imaging of in vitro chicken leg using time-resolved near-infrared optical tomography.

Near-infrared optical imaging gains much attention because of its noninvasiveness and deep penetration depths into tissue. Here, we report near-infrared optical tomographic imaging of an in vitro chicken leg from time-resolved measurements. The in vitro chicken leg, dipped in a cylindrical container filled with diluted Intralipid-10% solution, was imaged with a multichannel time-resolved imaging system. A two-dimensional reconstruction algorithm based on a modified generalized pulse spectrum technique has been developed to reconstruct the images of both the absorption and reduced scattering coefficients simultaneously and quickly. The results demonstrate that a simultaneous reconstruction of absorption and reduced scattering coefficients from time-resolved measurement has a potential to reveal the changes in the optical properties associated with not only the physiological information but also the anatomical structure of the organ.

Algorithms↗

Improvement of image quality in diffuse optical tomography by use of full time-resolved data.

In the field of diffuse optical tomography (DOT), it is widely accepted that time-resolved (TR) measurement can provide the richest information on photon migration in a turbid medium, such as biological tissue. However, the currently available image reconstruction algorithms for TR DOT are based mostly on the cw component or some featured data types of original temporal profiles, which are related to the solution of a time-independent diffusion equation. Although this methodology can greatly simplify the reconstruction process, it suffers from low spatial resolution and poor quantitativeness owing to the limitation of effectively applicable data types. To improve image quality, it has been argued that exploiting the full TR data is essential. We propose implementation of a DOT algorithm by using full TR data and furthermore a variant algorithm with time slices of TR data to alleviate the computational complexity and enhance noise robustness. Compared with those algorithms where the featured data types are used, our evaluations on the spatial resolution and quantitativeness show that a significant improvement in imaging quality can be achieved when full TR data are used, which convinces the DOT community of the potential advantage of the TR domain over cw and frequency domains.

Humans↗